Clinical Ex Vivo Lung Perfusion - Pushing the Limits

被引:136
|
作者
Aigner, C. [1 ]
Slama, A. [1 ]
Hoetzenecker, K. [1 ]
Scheed, A. [1 ]
Urbanek, B. [2 ]
Schmid, W. [2 ]
Nierscher, F. J. [2 ]
Lang, G. [1 ]
Klepetko, W. [1 ]
机构
[1] Med Univ Vienna, Dept Thorac Surg, Vienna, Austria
[2] Med Univ Vienna, Dept Cardiothorac & Vasc Anesthesia & Intens Care, Vienna, Austria
关键词
EVLP; Ex vivo lung perfusion; lung transplantation; marginal donors; EXTENDED DONOR CRITERIA; UNITED-STATES; TRANSPLANTATION; ALLOCATION;
D O I
10.1111/j.1600-6143.2012.04027.x
中图分类号
R61 [外科手术学];
学科分类号
摘要
Ex vivo lung perfusion (EVLP) provides the ability to evaluate donor lungs before transplantation. Yet, limited prospective clinical data exist with regard to its potential to recondition unacceptable donor lungs. This paper summarizes the results of a prospective study of lung transplantation using only initially unacceptable donor lungs, which were improved by EVLP for 24 h. From March 2010June 2011, 13 lungs were evaluated ex vivo. Median donor PaO2 at FiO21.0/PEEP5 was 216 mmHg (range 133271). Four lungs, all with trauma history, showed no improvement and were discarded. Nine lungs improved to a ?PO2 higher than 350 mmHg. Median PvO2 at final assessment in these lungs was 466 mmHg (range 434525). These lungs were transplanted with a median total ischemic time of 577 min (range 486678). None of the patients developed primary graft dysfunction grades 2 or 3 within 72 h after transplantation. One patient with secondary pulmonary hypertension was left on a planned prolonged extracorporeal membrane oxygenation postoperatively. Median intubation time was 2 days. Thirty-day mortality was 0%. During the observation period, 119 patients received standard lung transplantation with comparable perioperative outcome. EVLP has a significant potential to improve the quality of otherwise unacceptable donor lungs.
引用
收藏
页码:1839 / 1847
页数:9
相关论文
共 50 条
  • [31] Current status and future potential of ex vivo lung perfusion in clinical lung transplantation
    Zhou, Alice L. L.
    Larson, Emily L. L.
    Ruck, Jessica M. M.
    Ha, Jinny S. S.
    Casillan, Alfred J. J.
    Bush, Errol L. L.
    ARTIFICIAL ORGANS, 2023, 47 (11) : 1700 - 1709
  • [32] Clinical significance of donor lung weight at procurement and during ex vivo lung perfusion
    Okamoto, Toshihiro
    Ayyat, Kamal S.
    Sakanoue, Ichiro
    Niikawa, Hiromichi
    Said, Sayf A.
    Ahmad, Usman
    Unai, Shinya
    Bribriesco, Alejandro
    Elgharably, Haytham
    Budev, Marie M.
    Yun, James J.
    McCurry, Kenneth R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2022, 41 (06): : 818 - 828
  • [33] EARLY CLINICAL EXPERIANCE OF LUNG TRANSPLANTATION AFTER EX-VIVO LUNG PERFUSION
    Wallinder, Andreas
    Ricksten, Sven-Erik
    Riise, Gerdt
    Hansson, Christoffer
    Silverborn, Martin
    Liden, Hans
    Dellgren, Goran
    TRANSPLANT INTERNATIONAL, 2011, 24 : 347 - 348
  • [34] The Clinical Significance of Donor Lung Weight at Procurement and during Ex Vivo Lung Perfusion
    Okamoto, T.
    Ayyat, K. S.
    Sakanoue, I.
    Niikawa, H.
    Said, S. A.
    Ahmad, U.
    Unai, S.
    Bribriesco, A.
    Elgharably, H.
    Yun, J. J.
    Budev, M.
    McCurry, K. R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2021, 40 (04): : S328 - S329
  • [35] Feasibility of lung microdialysis to assess metabolism during clinical ex vivo lung perfusion
    Mazzeo, Anna Teresa
    Fanelli, Vito
    Boffini, Massimo
    Medugno, Mariangela
    Filippini, Claudia
    Simonato, Erika
    Costamagna, Andrea
    Delsedime, Luisa
    Brazzi, Luca
    Rinaldi, Mauro
    Ranieri, V. Marco
    Mascia, Luciana
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2019, 38 (03): : 267 - 276
  • [36] Ex Vivo Lung Perfusion in Lung Transplantation REPLY
    Keshavjee, Shaf
    Cypel, Marcelo
    NEW ENGLAND JOURNAL OF MEDICINE, 2011, 365 (01): : 92 - 92
  • [37] The Conversional Efficacy of Ex Vivo Lung Perfusion and Clinical Outcomes in Patients Undergoing Transplantation of Donor Lungs by Ex Vivo Lung Perfusion: A Meta-Analysis
    Luo, Qiuping
    Zhu, Linhai
    Wang, Yiqing
    Wang, Luming
    Lv, Wang
    Hu, Jian
    ANNALS OF TRANSPLANTATION, 2019, 24 : 647 - 660
  • [38] Pushing the Limits in Donation After Circulatory Death Donor Selection: Optimizing Graft Rehabilitation With Ex Vivo Machine Perfusion
    Magistri, Paolo
    Olivieri, Tiziana
    Guidetti, Cristiano
    Guerrini, Gian Piero
    Agnoletti, Vanni
    Muiesan, Paolo
    Di Benedetto, Fabrizio
    LIVER TRANSPLANTATION, 2020, 26 (10) : 1368 - 1372
  • [39] "Ex'' becomes "in'': A new direction for ex vivo lung perfusion?
    Dark, John H.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (01): : 438 - 439
  • [40] Devices for ex vivo heart and lung perfusion
    Schraufnagel, Dean P.
    Steffen, Robert J.
    Vargo, Patrick R.
    Attia, Tamer
    Elgharably, Haytham
    Hasan, Saad M.
    Bribriesco, Alejandro
    Wierup, Per
    EXPERT REVIEW OF MEDICAL DEVICES, 2018, 15 (03) : 183 - 191