Stiffness and compactness of morselized grafts during impaction - An in vitro study with human femoral heads

被引:51
作者
Bavadekar, A
Cornu, O
Godts, B
Delloye, C
Van Tomme, J
Banse, X
机构
[1] Univ Catholique Louvain, Orthopaed Res Lab, BE-1200 Brussels, Belgium
[2] Royal Mil Acad, Dept Civil Engn, Brussels, Belgium
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 2001年 / 72卷 / 05期
关键词
D O I
10.1080/000164701753532790
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The mechanical properties of the impacted material is important when using impaction bone grafting in revision arthroplasty. We did an in vitro study to monitor the stiffness and compactness of morsellized bone grafts during impaction. Using human osteoarthrotic femoral heads as the bone source we prepared 3 types of morselized grafts with the same bone mill: (1) purely cancellous grafts, (2) cortico-cancellous grafts and (3) cortico-cancellous bone with cartilage remnants. 5 g of bone samples were progressively impacted up to 150 times in a contained cavity. All types of grafts became stiffer and stiffer during the first 30 impactions. After 30 impactions, the grafts' compactness continued to increase slowly without concomitant changes in their stiffness. Over-impaction was not useful, but did not jeopardize the implant stability. The presence of cartilage remnants considerably compromised the increase in stiffness. In contrast, the addition of cortical bone from the femoral neck did not affect the impaction and resultant stiffness.
引用
收藏
页码:470 / 476
页数:7
相关论文
共 13 条
[1]   Mechanical considerations in impaction bone grafting [J].
Brewster, NT ;
Brewster, WJ ;
Howie, CR ;
Madabhushi, SPG ;
Usmani, AS ;
Fairbairn, DR .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (01) :118-124
[2]   Mechanical behavior of human morselized cancellous bone in triaxial compression testing [J].
Brodt, MD ;
Swan, CC ;
Brown, TD .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1998, 16 (01) :43-49
[3]   MECHANICAL PROPERTY DISTRIBUTIONS IN THE CANCELLOUS BONE OF THE HUMAN PROXIMAL FEMUR [J].
BROWN, TD ;
FERGUSON, AB .
ACTA ORTHOPAEDICA SCANDINAVICA, 1980, 51 (03) :429-437
[4]   Supply and demand of bone allograft for revision hip surgery in Scotland [J].
Galea, G ;
Kopman, D ;
Graham, BJM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (04) :595-599
[5]   IMPACTED CANCELLOUS ALLOGRAFTS AND CEMENT FOR REVISION TOTAL HIP-ARTHROPLASTY [J].
GIE, GA ;
LINDER, L ;
LING, RSM ;
SIMON, IP ;
SLOOFF, TJJH ;
TIMPERLEY, AJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (01) :14-21
[6]  
GIE GA, 1993, ORTHOP CLIN N AM, V24, P717
[7]   Mechanical characteristics of impacted morsellised bone grafts used in revision of total hip arthroplasty [J].
Giesen, EBW ;
Lamerigts, NMP ;
Verdonschot, N ;
Buma, P ;
Schreurs, BW ;
Huiskes, R .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (06) :1052-1057
[8]   Subsidence of a non-polished stem in revisions of the hip using impaction allograft -: Evaluation with radiostereometry and dual-energy X-ray absorptiometry [J].
Kärrholm, J ;
Hultmark, P ;
Carlsson, L ;
Malchau, H .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (01) :135-142
[9]   MECHANICAL-BEHAVIOR OF DAMAGED TRABECULAR BONE [J].
KEAVENY, TM ;
WACHTEL, EF ;
GUO, XE ;
HAYES, WC .
JOURNAL OF BIOMECHANICS, 1994, 27 (11) :1309-1318
[10]   Femoral component revision using impacted morsellised cancellous graft [J].
Ling, RSM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (05) :874-874