Aortic Annular Sizing Using a Novel 3-Dimensional Echocardiographic Method Use and Comparison With Cardiac Computed Tomography

被引:106
作者
Khalique, Omar K. [1 ]
Kodali, Susheel K. [1 ]
Paradis, Jean-Michel [1 ]
Nazif, Tamim M. [1 ]
Williams, Mathew R. [2 ]
Einstein, Andrew J. [1 ]
Pearson, Gregory D. [3 ]
Harjai, Kishore [1 ]
Grubb, Kendra [2 ]
George, Isaac [2 ]
Leon, Martin B. [1 ]
Hahn, Rebecca T. [1 ]
机构
[1] Columbia Univ, Med Ctr, New York Presbyterian Hosp, Dept Cardiol, New York, NY 10032 USA
[2] Columbia Univ, Med Ctr, New York Presbyterian Hosp, Dept Surg, New York, NY 10032 USA
[3] Columbia Univ, Med Ctr, New York Presbyterian Hosp, Dept Radiol, New York, NY 10032 USA
关键词
aortic valve insufficiency; aortic valve stenosis; echocardiography; tomography; PREDICTING PARAVALVULAR REGURGITATION; VALVE IMPLANTATION; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; SAPIEN XT; TRANSCATHETER; REPLACEMENT; PROSTHESIS; ACCURACY; IMPACT; VALIDATION;
D O I
10.1161/CIRCIMAGING.113.001153
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Previous studies have shown cross-sectional 3-dimensional (3D) transesophageal echocardiographic (TEE) measurements to severely underestimate multidetector row computed tomographic (MDCT) measurements for the assessment of aortic annulus before transcatheter aortic valve replacement. This study compares annulus measurements from 3D-TEE using off-label use of commercially available software with MDCT measurements and assesses their ability to predict paravalvular regurgitation. Methods and Results One hundred patients with severe, symptomatic aortic stenosis who had both contrast MDCT and 3D-TEE for annulus assessment before balloon-expandable transcatheter aortic valve replacement were analyzed. Annulus area, perimeter, and orthogonal maximum and minimum diameters were measured. Receiver operating characteristic analysis was performed with mild or greater paravalvular regurgitation as the classification variable. Three-dimensional TEE and MDCT cross-sectional perimeter and area measurements were strongly correlated (r=0.93-0.94; P<0.0001); however, the small differences (1%) were statistically significant (P=0.0002 and 0.0074, respectively). Discriminatory ability for mild paravalvular regurgitation was good for both MDCT (area under the curve for perimeter and area cover index=0.715 and 0.709, respectively) and 3D-TEE (area under the curve for perimeter and area cover index=0.709 and 0.694, respectively). Differences in receiver operating characteristic analysis between MDCT and 3D-TEE perimeter and area cover indexes were not statistically significant (P=0.15 and 0.35, respectively). Conclusions Annulus measurements using a new method for analyzing 3D-TEE images closely approximate those of MDCT. Annulus measurements from both modalities predict mild or greater paravalvular regurgitation with equivalent accuracy.
引用
收藏
页码:155 / 163
页数:9
相关论文
共 48 条
[1]   Prevention and Management of Transcatheter Balloon-Expandable Aortic Valve Malposition [J].
Al Ali, Abdullah M. ;
Altwegg, Lukas ;
Horlick, Eric M. ;
Feindel, Christopher ;
Thompson, Christopher R. ;
Cheung, Anson ;
Carere, Ronald G. ;
Humphries, Karin ;
Ye, Jian ;
Masson, Jean-Bernard ;
Webb, John G. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (04) :573-578
[2]   Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation [J].
Altiok, Ertunc ;
Koos, Ralf ;
Schroeder, Joerg ;
Brehmer, Kathrin ;
Hamada, Sandra ;
Becker, Michael ;
Mahnken, Andreas H. ;
Almalla, Mohammad ;
Dohmen, Guido ;
Autschbach, Ruediger ;
Marx, Nikolaus ;
Hoffmann, Rainer .
HEART, 2011, 97 (19) :1578-1584
[3]   Incidence, Predictors, and Outcomes of Aortic Regurgitation After Transcatheter Aortic Valve Replacement Meta-Analysis and Systematic Review of Literature [J].
Athappan, Ganesh ;
Patvardhan, Eshan ;
Tuzcu, E. Murat ;
Svensson, Lars Georg ;
Lemos, Pedro A. ;
Fraccaro, Chiara ;
Tarantini, Giuseppe ;
Sinning, Jan-Malte ;
Nickenig, Georg ;
Capodanno, Davide ;
Tamburino, Corrado ;
Latib, Azeem ;
Colombo, Antonio ;
Kapadia, Samir R. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (15) :1585-1595
[4]   An overview on assessing agreement with continuous measurements [J].
Barnhart, Huiman X. ;
Haber, Michael J. ;
Lin, Lawrence I. .
JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2007, 17 (04) :529-569
[5]   A Practical Guide to Multimodality Imaging of Transcatheter Aortic Valve Replacement [J].
Bloomfield, Gerald S. ;
Gillam, Linda D. ;
Hahn, Rebecca T. ;
Kapadia, Samir ;
Leipsic, Jonathon ;
Lerakis, Stamatios ;
Tuzcu, Murat ;
Douglas, Pamela S. .
JACC-CARDIOVASCULAR IMAGING, 2012, 5 (04) :441-455
[6]   Computed tomography-based evaluation of aortic annulus, prosthesis size and impact on early residual aortic regurgitation after transcatheter aortic valve implantation [J].
Buzzatti, Nicola ;
Maisano, Francesco ;
Latib, Azeem ;
Cioni, Micaela ;
Taramasso, Maurizio ;
Mussardo, Marco ;
Colombo, Antonio ;
Alfieri, Ottavio .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2013, 43 (01) :43-51
[7]   Transesophageal echocardiographic scoring for transcatheter aortic valve implantation: Impact of aortic cusp calcification on postoperative aortic regurgitation [J].
Colli, Andrea ;
D'Amico, Roberto ;
Kempfert, Joerg ;
Borger, Michael A. ;
Mohr, Friedrich W. ;
Walther, Thomas .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 142 (05) :1229-1235
[8]   Preoperative Assessment of Aortic Annulus Dimensions: Comparison of Noninvasive and Intraoperative Measurement [J].
Dashkevich, Alexey ;
Blanke, Philipp ;
Siepe, Matthias ;
Pache, Gregor ;
Langer, Mathias ;
Schlensak, Christian ;
Beyersdorf, Friedhelm .
ANNALS OF THORACIC SURGERY, 2011, 91 (03) :709-715
[9]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[10]   Prospective analysis of 30-day safety and performance of transfemoral transcatheter aortic valve implantation with Edwards SAPIEN XT versus SAPIEN prostheses [J].
Eltchaninoff, Helene ;
Durand, Eric ;
Borz, Bogdan ;
Godin, Matthieu ;
Tron, Christophe ;
Litzler, Pierre-Yves ;
Bessou, Jean-Paul ;
Bejar, Karim ;
Fraccaro, Chiara ;
Sanchez-Giron, Carlos ;
Dacher, Jean-Nicolas ;
Bauer, Fabrice ;
Cribier, Alain .
ARCHIVES OF CARDIOVASCULAR DISEASES, 2012, 105 (03) :132-140