Surface Modification of Ultra-high Molecular Weight Polyethylene Membranes Using Underwater Plasma Polymerization

被引:23
作者
Joshi, Ranjit [1 ]
Friedrich, Joerg [2 ,3 ]
Krishna-Subramanian, Santosh [4 ]
机构
[1] Clariant Chem India Ltd, Global Technol Serv, Sandoz Baug 400607, Thane, India
[2] BAM Fed Inst Mat Res & Testing, Div Polymer Surfaces, D-12205 Berlin, Germany
[3] Tech Univ Berlin, D-10623 Berlin, Germany
[4] Humboldt Univ, Univ Clin 1, Charite, D-12203 Berlin, Germany
关键词
Glow discharge electrolysis (GDE); UHMWPE membrane; Pore modification; Adhesion; Copolymer hydrogel; GLOW-DISCHARGE ELECTROLYSIS; INITIATED POLYMERIZATION; FUNCTIONAL-GROUPS; POLYPROPYLENE; ADHESION; POLYMERS; HYDROGEN; DENSITY; OH;
D O I
10.1007/s11090-013-9476-2
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Ultra-high molecular weight polyethylene membranes were modified and subsequently polymer coated using the underwater plasma produced by glow discharge electrolysis. This plasma pretreatment generated various O-functional groups among them OH groups have dominated. This modified inner (pore) surface of membranes showed complete wetting and strong adhesion to a hydrogel copolymerized by glow discharge electrolysis also. The deposited hydrogel consists of plasma polymerized acrylic acid crosslinked by copolymerization with the bifunctional N,N'-methylenebis(acrylamide). Tuning the hydrogel hydrophilicity and bio-compatibility poly(ethylene glycol) was chemically inserted into the copolymer. Such saturated polymer could only be inserted on a non-classic way by (partial) fragmentation and recombination thus demonstrating the exotic properties of the underwater plasma. The modification of membrane was achieved by squeezing the reactive plasma solution into the pores by plasma-induced shock waves and supported by intense stirring. The deposited copolymer hydrogel has filled all pores also in the inner of membrane as shown by scanning electron microscopy of cross-sections. The copolymer shows the characteristic units of acrylic acid and ethylene glycol as demonstrated by infrared spectroscopy. A minimum loss in carboxylic groups of acrylic acid during the plasma polymerization process was confirmed by X-ray photoelectron spectroscopy. Additional cell adhesion tests on copolymer coated polyethylene using IEC-6 cells demonstrated the bio-compatibility of the plasma-deposited hydrogel.
引用
收藏
页码:921 / 940
页数:20
相关论文
共 49 条
[1]  
Alexander MR, 1998, J MATER CHEM, V8, P937
[2]  
[Anonymous], 1992, HIGH RESOLUTION XPS, DOI DOI 10.1002/ADMA.19930051035
[3]   STUDIES IN POLYMER SURFACE FUNCTIONALIZATION AND GRAFTING FOR BIOMEDICAL AND OTHER APPLICATIONS [J].
BAMFORD, CH ;
ALLAMEE, KG .
POLYMER, 1994, 35 (13) :2844-2852
[4]   ELECTRON-SPIN RESONANCE DETECTION OF SPIN-TRAPPED RADICALS FORMED DURING THE GLOW-DISCHARGE ELECTROLYSIS OF AQUEOUS-SOLUTIONS [J].
BULLOCK, AT ;
GAVIN, DL ;
INGRAM, MD .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1980, 76 :648-653
[5]   Cell interactions with three-dimensional matrices [J].
Cukierman, E ;
Pankov, R ;
Yamada, KM .
CURRENT OPINION IN CELL BIOLOGY, 2002, 14 (05) :633-639
[6]  
del Fanti N.A., 2008, INFRARED SPECTROSCOP
[7]   POLYMERIZATION BY GLOW-DISCHARGE ELECTROLYSIS [J].
DENARO, AR ;
HOUGH, KO .
ELECTROCHIMICA ACTA, 1973, 18 (11) :863-868
[8]  
DYCKERHOFF GA, 1972, ANGEW MAKROMOL CHEM, V21, P169
[9]  
ELIAS HG, 1990, MAKROMOLEKULE, V1
[10]   Tailoring of polymer surfaces with monotype functional groups of variable density using chemical and plasma chemical processes [J].
Friedrich, J. ;
Kuehn, G. ;
Mix, R. ;
Hoffmann, K. ;
Resch-Genger, U. .
CHARACTERIZATION OF POLYMER SURFACES AND THIN FILMS, 2006, 132 :62-+