Prospective Study of Tricuspid Regurgitation Associated With Permanent Leads After Cardiac Rhythm Device Implantation

被引:43
作者
Van De Heyning, Caroline M. [1 ]
Elbarasi, Esam [2 ]
Masiero, Simona [3 ]
Brambatti, Michela [4 ]
Ghazal, Sami [2 ]
Al-Maashani, Said [2 ]
Capucci, Alessandro [3 ]
Leong, Darryl [2 ]
Shivalkar, Bharati [1 ]
Saenen, Johan B. [1 ]
Miljoen, Hielko P. [1 ]
Morillo, Carlos A. [2 ]
Divarakarmenon, Syamkumar [2 ]
Amit, Guy [2 ]
Ribas, Sebastian [2 ]
Baiocco, Erika [3 ]
Maolo, Alessandro [3 ]
Romandini, Andrea [3 ]
Maffei, Simone [3 ]
Connolly, Stuart J. [2 ]
Healey, Jeff S. [2 ]
Dokainish, Hisham [2 ]
机构
[1] Antwerp Univ Hosp, Dept Cardiol, Edegem, Belgium
[2] McMaster Univ, Dept Cardiol, 237 Barton St E,CVSRI C3 111, Hamilton, ON L8L 2X2, Canada
[3] Univ Politecn Belle Marche, Dept Cardiol, Ancona, Italy
[4] Univ Calif San Diego, Div Cardiol, San Diego, CA 92103 USA
关键词
FUNCTIONAL MITRAL REGURGITATION; CARDIOVERTER-DEFIBRILLATOR; EUROPEAN ASSOCIATION; ECHOCARDIOGRAPHIC-ASSESSMENT; RESYNCHRONIZATION THERAPY; ATRIOVENTRICULAR-BLOCK; TRANSVENOUS PACEMAKER; VENTRICULAR-FUNCTION; AMERICAN SOCIETY; HEART;
D O I
10.1016/j.cjca.2018.11.014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Tricuspid regurgitation (TR) has been associated with cardiac rhythm device (CRD) implantation with intracardiac lead insertion. However, data on the incidence of postdevice TR are limited and largely from retrospective studies. We hypothesized that permanent lead implantation would be associated with an increase in TR. Methods: We prospectively included consecutive patients with a clinical indication for CRD. Patients underwent transthoracic echocardiography 1 month before and 1 year after CRD implantation. Results: A total of 328 patients were prospectively enrolled (69 +/- 15 years, 38% female). Echocardiograms before and 1 year after CRD were available in 290 patients (15 died, 23 lost to follow-up). Compared with baseline, there was a significant change in TR grade 1 year after CRD insertion (no/trivial TR: 66% vs 29%; mild TR: 29% vs 61%; moderate TR: 3% vs 8%; severe TR 2% vs 2%; P < 0.001 for an increase in TR by at least 1 grade). Compared with baseline, there was a higher prevalence of moderate or severe TR in the 247 patients with CRD without cardiac resynchronization therapy (4% vs 10%, P = 0.004), but no progression in the 43 patients who received cardiac resynchronization therapy (14% vs 11%, P = 1). Multivariable analysis in the patients with less than moderate TR at baseline (n = 274) showed that only a history of atrial fibrillation was independently associated with progression to moderate or severe TR after correction for baseline TR grade (P = 0.013). Conclusions: One year after endocardial lead insertion, there was a 5% increase in the prevalence of moderate or severe TR, which may be clinically relevant.
引用
收藏
页码:389 / 395
页数:7
相关论文
共 27 条
[1]   Tricuspid Regurgitation and Implantable Devices [J].
Al-Bawardy, Rasha ;
Krishnaswamy, Amar ;
Rajeswaran, Jeevanantham ;
Bhargava, Mandeep ;
Wazni, Oussama ;
Wilkoff, Bruce ;
Tuzcu, Emin Murat ;
Martin, David ;
Thomas, James ;
Blackstone, Eugene ;
Kapadia, Samir .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (02) :259-266
[2]   Effects of pacemaker and implantable cardioverter defibrillator electrodes on tricuspid regurgitation and right sided heart functions [J].
Arabi, Peyman ;
Ozer, Necla ;
Ates, Ahmet Hakan ;
Yorgun, Hikmet ;
Oto, Ali ;
Aytemir, Kudret .
CARDIOLOGY JOURNAL, 2015, 22 (06) :637-644
[3]   Implant and Midterm Outcomes of the Subcutaneous Implantable Cardioverter-Defibrillator Registry The EFFORTLESS Study [J].
Boersma, Lucas ;
Barr, Craig ;
Knops, Reinoud ;
Theuns, Dominic ;
Eckardt, Lars ;
Neuzil, Petr ;
Scholten, Marcoen ;
Hood, Margaret ;
Kuschyk, Juergen ;
Jones, Paul ;
Duffy, Elizabeth ;
Husby, Michael ;
Stein, Kenneth ;
Lambiase, Pier D. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (07) :830-841
[4]   Tricuspid Valve Dysfunction Following Pacemaker or Cardioverter-Defibrillator Implantation [J].
Chang, James D. ;
Manning, Warren J. ;
Ebrille, Elisa ;
Zimetbaum, Peter J. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (18) :2331-2341
[5]  
Curtis AB, 2013, NEW ENGL J MED, V369, P579, DOI [10.1056/NEJMoa1210356, 10.1056/NEJMc1306998]
[6]   Tricuspid Regurgitation and Mortality in Patients With Transvenous Permanent Pacemaker Leads [J].
Delling, Francesca N. ;
Hassan, Zena K. ;
Piatkowski, Gail ;
Tsao, Connie W. ;
Rajabali, Alefiyah ;
Markson, Lawrence J. ;
Zimetbaum, Peter J. ;
Manning, Warren J. ;
Chang, James D. ;
Mukamal, Kenneth J. .
AMERICAN JOURNAL OF CARDIOLOGY, 2016, 117 (06) :988-992
[7]  
Dokainish H, 2015, GLOB CARDIOL SCI PRA, V41
[8]   The effects of right ventricular apical pacing with transvenous pacemaker and implantable cardioverter defibrillator on mitral and tricuspid regurgitation [J].
Fanari, Zaher ;
Hammami, Sumaya ;
Hammami, Muhammad Baraa ;
Hammami, Safa ;
Shuraih, Mossaab .
JOURNAL OF ELECTROCARDIOLOGY, 2015, 48 (05) :791-797
[9]   Significant lead-induced tricuspid regurgitation is associated with poor prognosis at long-term follow-up [J].
Hoke, Ulas ;
Auger, Dominique ;
Thijssen, Joep ;
Wolterbeek, Ron ;
van der Velde, Enno T. ;
Holman, Eduard R. ;
Schalij, Martin J. ;
Bax, Jeroen J. ;
Delgado, Victoria ;
Marsan, Nina Ajmone .
HEART, 2014, 100 (12) :960-968
[10]   Tricuspid insufficiency does not increase early after permanent implantation of pacemaker leads [J].
Kucukarslan, N ;
Kirilmaz, A ;
Ulusoy, E ;
Yokusoglu, M ;
Gramatnikovski, N ;
Ozal, E ;
Tatar, H .
JOURNAL OF CARDIAC SURGERY, 2006, 21 (04) :391-394