Instrumental validity and intra/inter-rater reliability of a novel low-cost digital pressure algometer

被引:13
|
作者
Jerez-Mayorga, Daniel [1 ]
dos Anjos, Carolina Fernanda [2 ]
Macedo, Maria de Cassia [2 ]
Fernandes, Ilha Goncalves [2 ]
Aedo-Munoz, Esteban [3 ]
Intelangelo, Leonardo [4 ]
Barbosa, Alexandre Carvalho [2 ]
机构
[1] Univ Andres Bello, Fac Ciencias Rehabil, Santiago, Chile
[2] Univ Fed Juiz de Fora, Dept Phys Therapy, Governador Valadares, MG, Brazil
[3] Univ Fed Juiz de Fora, Dept Phys Educ, Governador Valadares, MG, Brazil
[4] Univ Gran Rosario, Dept Phys Therapy, Rosario, Santa Fe, Argentina
来源
PEERJ | 2020年 / 8卷
关键词
Pain assessment; Validity; Reliability; Pressure algometry; Pressure pain threshold; Inexpensive; PAIN THRESHOLD; SEX-DIFFERENCES; INDIVIDUALS; SENSITIVITY; VALIDATION; EXERCISE;
D O I
10.7717/peerj.10162
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Pain assessment is a key measure that accompanies treatments in a wide range of clinical settings. A low-cost valid and reliable pressure algometer would allow objective assessment of pressure pain to assist a variety of health professionals. However, the pressure algometer is often expensive, which limits its daily use in both clinical and research settings. Objectives: This study aimed to assess the instrumental validity, and the intraand inter-rater reliability of an inexpensive digital adapted pressure algometer. Methods: A single rater applied 60 random compressions on a force platform. The pressure pain thresholds of 20 volunteers were collected twice (3 days apart ) by two raters. The main outcome measurements were as follows: the maximal peak force (in kPa) and the pressure pain threshold (adapted pressure algometer vs. force platform). Cronbach's a test was used to assess internal consistency. The standard error of measurement provided estimates of measurement error, and the measurement bias was estimated with the Bland-Altman method, with lower and upper limits of agreement. Results: No differences were observed when comparing the compression results (P = 0.51). The validity and internal intra-rater consistencies ranged from 0.84 to 0.99, and the standard error of measurement from 0.005 to 0.04 kPa. Very strong (r = 0.73-0.74) to near-perfect (r = 0.99) correlations were found, with a low risk of bias for all measurements. The results demonstrated the validity and intra-rater reliability of the digitally adapted pressure algometer. Inter-rater reliability results were moderate (r = 0.55-0.60; Cronbach's alpha = 0.71-0.75). Conclusion: The adapted pressure algometer provide valid and reliable measurements of pressure pain threshold. The results support more widespread use of the pressure pain threshold method among clinicians.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Inter-rater and intra-rater reliability of Kinovea software for measurement of shoulder range of motion
    Reham M. Abd Elrahim
    Eman A. Embaby
    Mohamed F. Ali
    Ragia M. Kamel
    Bulletin of Faculty of Physical Therapy, 2016, 21 (2) : 80 - 87
  • [32] Inter-rater and Intra-rater Reliability of the Chinese Version of the Action Research Arm Test in People With Stroke
    Zhao, Jiang-Li
    Chen, Pei-Ming
    Zhang, Tao
    Li, Hai
    Lin, Qiang
    Mao, Yu-Rong
    Huang, Dong-Feng
    FRONTIERS IN NEUROLOGY, 2019, 10
  • [33] Inter-rater and intra-rater reliability of the current assessment model and tools for laparoscopic suturing
    Chin-Hung Wei
    Shih-Chiang Shen
    Yih-Cherng Duh
    Kuei‐Yen Tsai
    Hsin-An Chen
    Shih-Wei Huang
    Surgical Endoscopy, 2022, 36 : 6586 - 6591
  • [34] Inter-rater, intra-rater and inter-instrument reliability of an electrogoniometer to measure wrist range of motion
    da Silva Camassuti, Patricia Aparecida
    Marcolino, Alexandre Marcio
    Tamanini, Guilherme
    Barbosa, Rafael Inacio
    Barbosa, Amanda Matias
    Registro Fonseca, Marisa de Cassia
    HAND THERAPY, 2015, 20 (01) : 3 - 10
  • [35] Intra-rater and inter-rater reliability of Surgimap Spine software for measuring spinal postural angles from digital photographs
    Nesma A. Helmya
    Mohsen M. El-Sayyadb
    Omaima M. Kattabeib
    Bulletin of Faculty of Physical Therapy, 2015, 20 (2) : 193 - 199
  • [36] Intra-Rater and Inter-Rater Reliability of Pressure Pain Algometry of the Sural and Tibial Nerves in Asymptomatic Elite Youth Footballers
    Richards, Daniel
    Jones, Simon
    Jeffery, Josh
    Lowe, Matthew
    Godwin, Mark
    Willett, Matthew
    SPORTS, 2021, 9 (09)
  • [37] Ultrasound Imaging Analysis of the Lumbar Multifidus Muscle Echo Intensity: Intra-Rater and Inter-Rater Reliability of a Novice and an Experienced Rater
    Fortin, Maryse
    Rosenstein, Brent
    Levesque, Jerome
    Nandlall, Neil
    MEDICINA-LITHUANIA, 2021, 57 (05):
  • [38] Inter-Rater Reliability and Validity of the OPD-CA Axes Structure and Conflict
    Benecke, Cord
    Bock, Astrid
    Wieser, Elke
    Tschiesner, Reinhard
    Lochmann, Martha
    Kuespert, Felicia
    Schorn, Robert
    Viertler, Bernhard
    Steinmayr-Gensluckner, Maria
    PRAXIS DER KINDERPSYCHOLOGIE UND KINDERPSYCHIATRIE, 2011, 60 (01) : 60 - 73
  • [39] Intra- and inter-rater reliability for analysis of hyoid displacement measured with sonography
    Macrae, Phoebe R.
    Doeltgen, Sebastian H.
    Jones, Richard D.
    Huckabee, Maggie-Lee
    JOURNAL OF CLINICAL ULTRASOUND, 2012, 40 (02) : 74 - 78
  • [40] Inter-rater reliability and validity of the Ministry of Health of Turkey's mandatory emergency triage instrument
    Erimsah, M. Emre
    Yaka, Elif
    Yilmaz, Serkan
    Kama, Ahmet
    Pekdemir, Murat
    EMERGENCY MEDICINE AUSTRALASIA, 2015, 27 (03) : 210 - 215