Instrumental validity and intra/inter-rater reliability of a novel low-cost digital pressure algometer

被引:13
|
作者
Jerez-Mayorga, Daniel [1 ]
dos Anjos, Carolina Fernanda [2 ]
Macedo, Maria de Cassia [2 ]
Fernandes, Ilha Goncalves [2 ]
Aedo-Munoz, Esteban [3 ]
Intelangelo, Leonardo [4 ]
Barbosa, Alexandre Carvalho [2 ]
机构
[1] Univ Andres Bello, Fac Ciencias Rehabil, Santiago, Chile
[2] Univ Fed Juiz de Fora, Dept Phys Therapy, Governador Valadares, MG, Brazil
[3] Univ Fed Juiz de Fora, Dept Phys Educ, Governador Valadares, MG, Brazil
[4] Univ Gran Rosario, Dept Phys Therapy, Rosario, Santa Fe, Argentina
来源
PEERJ | 2020年 / 8卷
关键词
Pain assessment; Validity; Reliability; Pressure algometry; Pressure pain threshold; Inexpensive; PAIN THRESHOLD; SEX-DIFFERENCES; INDIVIDUALS; SENSITIVITY; VALIDATION; EXERCISE;
D O I
10.7717/peerj.10162
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Pain assessment is a key measure that accompanies treatments in a wide range of clinical settings. A low-cost valid and reliable pressure algometer would allow objective assessment of pressure pain to assist a variety of health professionals. However, the pressure algometer is often expensive, which limits its daily use in both clinical and research settings. Objectives: This study aimed to assess the instrumental validity, and the intraand inter-rater reliability of an inexpensive digital adapted pressure algometer. Methods: A single rater applied 60 random compressions on a force platform. The pressure pain thresholds of 20 volunteers were collected twice (3 days apart ) by two raters. The main outcome measurements were as follows: the maximal peak force (in kPa) and the pressure pain threshold (adapted pressure algometer vs. force platform). Cronbach's a test was used to assess internal consistency. The standard error of measurement provided estimates of measurement error, and the measurement bias was estimated with the Bland-Altman method, with lower and upper limits of agreement. Results: No differences were observed when comparing the compression results (P = 0.51). The validity and internal intra-rater consistencies ranged from 0.84 to 0.99, and the standard error of measurement from 0.005 to 0.04 kPa. Very strong (r = 0.73-0.74) to near-perfect (r = 0.99) correlations were found, with a low risk of bias for all measurements. The results demonstrated the validity and intra-rater reliability of the digitally adapted pressure algometer. Inter-rater reliability results were moderate (r = 0.55-0.60; Cronbach's alpha = 0.71-0.75). Conclusion: The adapted pressure algometer provide valid and reliable measurements of pressure pain threshold. The results support more widespread use of the pressure pain threshold method among clinicians.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Creating a healthy eating and active environment survey (CHEERS) for childcare: an inter-rater, intra-rater reliability and validity study
    Lafave, Lynne M. Z.
    BMC PUBLIC HEALTH, 2019, 19 (01)
  • [22] Intra- and inter-rater reliability in ultrasonographic measurements of coracohumeral distance
    Guerra-Rodriguez, Diego
    Guerrero-Henriquez, Juan
    Basilio, Daniel
    Mendez-Rebolledo, Guillermo
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2024, 69
  • [23] Intra and inter-rater reliability of skin fold measurements in university men
    de Oliveira Filho, Aluizio Picanco
    de Brito, Alex Lima
    Viana, Albert da Silva
    de Sousa de Lima Deniur, Jose Rodrigo
    de Azevedo Albuquerque, Ana Paula
    Pureza, Demilto Yamaguchida
    Materko, Wollner
    RBNE-REVISTA BRASILEIRA DE NUTRICAO ESPORTIVA, 2018, 12 (76): : 1079 - 1085
  • [24] Intra and inter-rater reliability of a goniometric lower trunk rotation measurement
    Olson, Kenneth A.
    Goehring, Meri T.
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2009, 22 (03) : 157 - 164
  • [25] Intra and Inter-Rater Reliability of Ultrasound in Plantar Fascia Thickness Measurement
    Nakhaee, Masoomeh
    Mousavi, Mohammad Ebrahim
    Mohseni-Bandpei, Mohammad Ali
    Shakourirad, Ali
    Safari, Mohammad Reza
    Kashani, Reza Vahab
    Baneshi, Mohammad Reza
    Nakhaei, Masoud
    IRANIAN JOURNAL OF RADIOLOGY, 2018, 15 (03)
  • [26] Inter-rater and intra-rater reliability of the Brief-BESTest in people with chronic obstructive pulmonary disease
    Leung, Regina Wai Man
    Alison, Jennifer A.
    McKeough, Zoe J.
    CLINICAL REHABILITATION, 2019, 33 (01) : 104 - 112
  • [27] Intra-rater and Inter-rater Reliability of Mandibular Range of Motion Measures Considering a Neutral Craniocervical Position
    Beltran-Alacreu, Hector
    Lopez-de-Uralde-Villanueva, Ibai
    Paris-Alemany, Alba
    Angulo-Diaz-Parreno, Santiago
    La Touche, Roy
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2014, 26 (06) : 915 - 920
  • [28] Inter-rater and Intra-rater Reliability of a Mobile App Method to Measure Lumbar Lordosis
    Gnanasigamani, Jency Thangasheela
    Ramalingam, Vinodhkumar
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (03)
  • [29] INTER-RATER, INTRA-RATER, AND INTER-MACHINE RELIABILITY OF QUANTITATIVE ULTRASOUND MEASUREMENTS OF THE PATELLAR TENDON
    Gellhorn, Alfred C.
    Carlson, M. Jake
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (05) : 791 - 796
  • [30] Measuring the quality of life in mild to very severe dementia: Testing the inter-rater and intra-rater reliability of the German version of the QUALIDEM
    Dichter, Martin Nikolaus
    Schwab, Christian G. G.
    Meyer, Gabriele
    Bartholomeyczik, Sabine
    Dortmann, Olga
    Halek, Margareta
    INTERNATIONAL PSYCHOGERIATRICS, 2014, 26 (05) : 825 - 836