Ionic conductivity of peritoneal dialysate: a new, easy and fast method of assessing peritoneal membrane function in patients undergoing peritoneal dialysis

被引:5
作者
La Milia, Vincenzo [1 ]
Pontoriero, Giuseppe [1 ]
Virga, Giovambattista [2 ]
Locatelli, Francesco [1 ]
机构
[1] A Manzoni Hosp, Div Nephrol & Dialysis, Lecce, Italy
[2] Prov Hosp, Nephrol & Dialysis Unit, Padua, Italy
关键词
ionic conductivity; peritoneal equilibration test; peritoneal membrane function; ultrafiltration failure; EQUILIBRATION TEST; SOLUTE TRANSPORT; FREE-WATER; ULTRAFILTRATION; CAPD; FLUID; MODEL;
D O I
10.1093/ndt/gfv275
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background. Peritoneal membrane function can be assessed using the peritoneal equilibration test (PET) and similar tests, but these are almost always complicated to use, require a considerable amount of working time and their results cannot always be easily interpreted. Ionic conductivity is a measure of the ability of an electrolyte solution to conduct electricity. We tested the hypothesis that the ionic conductivity of peritoneal dialysate can be used to evaluate peritoneal membrane function in peritoneal dialysis patients. Methods. We measured the ionic conductivity and classic biochemical parameters of peritoneal dialysate in 69 patients during a modified PET and compared their ability to evaluate peritoneal membrane function and to diagnose ultrafiltration failure (UFF). Results. Ionic conductivity was correlated well with classical parameters of peritoneal transport as glucose reabsorption of glucose (D/D-0: r(2) = 0.62, P < 0.0001) and creatinine transport (D/P-Creat: r(2) = 0.72, P < 0.0001). Twelve patients (17%) experienced UFF and, in them, the ionic conductivity area under the receiver-operating characteristic curve was 0.91 (95% confidence interval: 0.81-0.96) with sensitivity of 1.00 and specificity of 0.84 at a cut-off value of 12.75 mS/cm. Conclusions. These findings indicate that the ionic conductivity of peritoneal dialysate can be used as a new screening tool to evaluate peritoneal membrane function.
引用
收藏
页码:1741 / 1746
页数:6
相关论文
共 22 条
[1]  
Altman DG., 1991, PRACTICAL STAT FO R, P409
[2]   Longitudinal relationship between solute transport and ultrafiltration capacity in peritoneal dialysis patients [J].
Davies, SJ .
KIDNEY INTERNATIONAL, 2004, 66 (06) :2437-2445
[3]  
Krediet RT, 2000, PERITON DIALYSIS INT, V20, pS22
[4]   Simultaneous measurement of peritoneal glucose and free water osmotic conductances [J].
La Milia, V. ;
Limardo, M. ;
Virga, G. ;
Crepaldi, M. ;
Locatelli, F. .
KIDNEY INTERNATIONAL, 2007, 72 (05) :643-650
[5]   Mini-peritoneal equilibration test: A simple and fast method to assess free water and small solute transport across the peritoneal membrane [J].
La Milia, V ;
Di Filippo, S ;
Crepaldi, M ;
Del Vecchio, L ;
Dell'Oro, C ;
Andrulli, S ;
Locatelli, F .
KIDNEY INTERNATIONAL, 2005, 68 (02) :840-846
[6]  
La Milia V, 2010, J NEPHROL, V23, P633
[7]   The peritoneal osmotic conductance is low well before the diagnosis of encapsulating peritoneal sclerosis is made [J].
Lambie, Mark L. ;
John, Biju ;
Mushahar, Lily ;
Huckvale, Christopher ;
Davies, Simon J. .
KIDNEY INTERNATIONAL, 2010, 78 (06) :611-618
[8]  
Mujais S, 2000, PERITON DIALYSIS INT, V20, pS5
[9]   Aquaporin-1 plays an essential role in water permeability and ultrafiltration during peritoneal dialysis [J].
Ni, J ;
Verbavatz, JM ;
Rippe, A ;
Boisdé, I ;
Moulin, P ;
Rippe, B ;
Verkman, AS ;
Devuyst, O .
KIDNEY INTERNATIONAL, 2006, 69 (09) :1518-1525
[10]   A MODEL FOR NONINVASIVE ESTIMATION OF IN-VIVO DIALYZER PERFORMANCES AND PATIENTS CONDUCTIVITY DURING HEMODIALYSIS [J].
PETITCLERC, T ;
GOUX, N ;
REYNIER, AL ;
BENE, B .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1993, 16 (08) :585-591