Transthoracic Doppler Echocardiographic Coronary Flow Imaging in Identification of Left Anterior Descending Coronary Artery Stenosis in Patients with Left Bundle Branch Block

被引:8
作者
Soylu, Ozer [1 ]
Celik, Seden [1 ]
Karakus, Gultekin [1 ]
Yildirim, Aydin [1 ]
Ergelen, Mehmet [1 ]
Zencirci, Ertugrul [1 ]
Aksu, Huseyin [1 ]
Tezel, Tuna [1 ]
机构
[1] Siyami Ersek Thorac & Cardiovasc Surg Training &, Dept Cardiol, Istanbul, Turkey
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2008年 / 25卷 / 10期
关键词
D O I
10.1111/j.1540-8175.2008.00729.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Conventional noninvasive methods have well-known limitations for the detection of coronary artery disease (CAD) in patients with left bundle branch block (LBBB). However, advancements in Doppler echocardiography permit transthoracic imaging of coronary flow velocities (CFV) and measurement of coronary flow reserve (CFR). Our aim was to evaluate the diagnostic value of transthoracic CFR measurements for detection of significant left anterior descending (LAD) stenosis in patients with LBBB and compare it to that of myocardial perfusion scintigraphy (MPS). Methods: Simultaneous transthoracic CFR measurements and MPS were analyzed in 44 consecutive patients with suspected CAD and permanent LBBB. Typical diastolic predominant phasic CFV Doppler spectra of distal LAD were obtained at rest and during a two-step (0.56-0.84 mg/ kg) dipyridamole infusion protocol. CFR was defined as the ratio of peak hyperemic velocities to the baseline values. A reversible perfusion defect at LAD territory was accepted as a positive scintigraphy finding for significant LAD stenosis. A coronary angiography was performed within 5 days of the CFR studies. Results: The hyperemic diastolic peak velocity (44 +/- 9 cm / sec vs 62 +/- 2 cm / sec; P = 0.01) and diastolic CFR (1.38 +/- 0.17 vs 1.93 +/- 0.3; P = 0.001) were significantly lower in patients with LAD stenosis compared to those without LAD stenosis. The diastolic CFR values of <1.6 yielded a sensitivity of 100% and a specificity of 94% in the identification of significant LAD stenosis. In comparison, MPS detected LAD stenosis with a sensitivity of 100% and a specificity of 29%. Conclusions: CFR measurement by transthoracic Doppler echocardiography is an accurate method that may improve noninvasive identification of LAD stenosis in patients with LBBB. (ECHOCARDIOGRAPHY, Volume 25, November 2008)
引用
收藏
页码:1065 / 1070
页数:6
相关论文
共 39 条
  • [1] TL-201 EXERCISE SCINTIGRAPHY AND LEFT-BUNDLE BRANCH-BLOCK
    BRAAT, SH
    BRUGADA, P
    BAR, FW
    GORGELS, APM
    WELLENS, HJJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1985, 55 (01) : 224 - 226
  • [2] IMPROVED SPECIFICITY OF MYOCARDIAL TL-201 SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY IN PATIENTS WITH LEFT-BUNDLE-BRANCH BLOCK BY DIPYRIDAMOLE
    BURNS, RJ
    GALLIGAN, L
    WRIGHT, LM
    LAWAND, S
    BURKE, RJ
    GLADSTONE, PJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (05) : 504 - 508
  • [3] EFFECT OF INTRAMYOCARDIAL PRESSURE ON PHASIC FLOW IN INTRAVENTRICULAR SEPTAL ARTERY
    CAREW, TE
    COVELL, JW
    [J]. CARDIOVASCULAR RESEARCH, 1976, 10 (01) : 56 - 64
  • [4] Physiologic assessment of coronary artery stenosis by coronary flow reserve measurements with transthoracic Doppler echocardiography: Comparison with exercise thallium-201 single-photon emission computed tomography
    Daimon, M
    Watanabe, H
    Yamagishi, H
    Muro, T
    Akioka, K
    Hirata, K
    Takeuchi, K
    Yoshikawa, J
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (05) : 1310 - 1315
  • [5] DEPUEY EG, 1988, J NUCL MED, V29, P1479
  • [7] GARCIA EV, 1990, J NUCL MED, V31, P1761
  • [8] TL-201 SCINTIGRAPHY IN COMPLETE LEFT-BUNDLE BRANCH-BLOCK
    HIRZEL, HO
    SENN, M
    NUESCH, K
    BUETTNER, C
    PFEIFFER, A
    HESS, OM
    KRAYENBUEHL, HP
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (06) : 764 - 769
  • [9] Noninvasive assessment of significant left anterior descending coronary artery stenosis by coronary flow velocity reserve with transthoracic color Doppler echocardiography
    Hozumi, T
    Yoshida, K
    Ogata, Y
    Akasaka, T
    Asami, Y
    Takagi, T
    Morioka, S
    [J]. CIRCULATION, 1998, 97 (16) : 1557 - 1562
  • [10] Noninvasive assessment of coronary flow velocity and coronary flow velocity reserve in the left anterior descending coronary artery by Doppler echocardiography - Comparison with invasive technique
    Hozumi, T
    Yoshida, K
    Akasaka, T
    Asami, Y
    Ogata, Y
    Takagi, T
    Kaji, S
    Kawamoto, T
    Ueda, Y
    Morioka, S
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (05) : 1251 - 1259