Performance testing of 2-fluid and 3-fluid liquid-to-air membrane energy exchangers for HVAC applications in cold-dry climates

被引:26
作者
Abdel-Salam, Mohamed R. H. [1 ]
Besant, Robert W. [1 ]
Simonson, Carey J. [1 ]
机构
[1] Univ Saskatchewan, Dept Mech Engn, 57 Campus Dr, Saskatoon, SK S7N 5A9, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
3-Fluid liquid-to-air membrane energy; exchanger (3-fluid LAMEE); Air heating and humidification; Liquid desiccant; Semi-permeable membrane; Phase change energy; Flow maldistribution; MASS-TRANSFER; CONDITIONING SYSTEM; DEHUMIDIFICATION; FLOW; POLLUTANTS; REMOVAL; LAMEES;
D O I
10.1016/j.ijheatmasstransfer.2016.09.024
中图分类号
O414.1 [热力学];
学科分类号
摘要
Liquid-to-air membrane energy exchangers (LAMEEs) can avoid the problem of desiccant droplets carryover by using semi-permeable membranes to separate the air and desiccant solution streams. The aim of this study is to test and compare the heat and moisture transfer performances between the air and desiccant solution inside a novel 3-fluid LAMEE and a 2-fluid LAMEE under air heating and humidifying conditions. The effect of flow maldistribution on the deterioration of the 3-fluid LAMEE's performance is estimated, and an experimental study of the feasibility of membrane pre-tension to reduce flow maldistribution caused by membrane deflections in flat-plate LAMEEs is presented. Unlike heat exchangers where the lowest possible outlet hot fluid temperature is equal to the inlet cold fluid temperature, experimental data show that the outlet desiccant solution (hot fluid) temperature in the 2-fluid LAMEE may be lower than the inlet air (cold fluid) temperature. This is attributed to the effect of the phase change energy associated with the air humidification process. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:558 / 569
页数:12
相关论文
共 30 条
[1]   Annual evaluation of energy, environmental and economic performances of a membrane liquid desiccant air conditioning system with/without ERV [J].
Abdel-Salam, Ahmed H. ;
Simonson, Carey J. .
APPLIED ENERGY, 2014, 116 :134-148
[2]   Performance Definitions for Three-Fluid Heat and Moisture Exchangers [J].
Abdel-Salam, Mohamed R. H. ;
Besant, Robert W. ;
Simonson, Carey J. .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2017, 139 (02)
[3]  
Abdel-Salam MRH, 2016, ASHRAE TRAN, V122, P134
[4]   Performance testing of a novel 3-fluid liquid-to-air membrane energy exchanger (3-fluid LAMEE) under desiccant solution regeneration operating conditions [J].
Abdel-Salam, Mohamed R. H. ;
Besant, Robert W. ;
Simonson, Carey J. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 95 :773-786
[5]   Design and testing of a novel 3-fluid liquid-to-air membrane energy exchanger (3-fluid LAMEE) [J].
Abdel-Salam, Mohamed R. H. ;
Besant, Robert W. ;
Simonson, Carey J. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 92 :312-329
[6]   Sensitivity of the performance of a flat-plate liquid-to-air membrane energy exchanger (LAMEE) to the air and solution channel widths and flow maldistribution [J].
Abdel-Salam, Mohamed R. H. ;
Besant, Robert W. ;
Simonson, Carey J. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 84 :1082-1100
[7]   State-of-the-art in liquid-to-air membrane energy exchangers (LAMEEs): A comprehensive review [J].
Abdel-Salam, Mohamed R. H. ;
Ge, Gaoming ;
Fauchoux, Melanie ;
Besant, Robert W. ;
Simonson, Carey J. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 39 :700-728
[8]   Expected energy and economic benefits, and environmental impacts for liquid-to-air membrane energy exchangers (LAMEEs) in HVAC systems: A review [J].
Abdel-Salam, Mohamed R. H. ;
Fauchoux, Melanie ;
Ge, Gaoming ;
Besant, Robert W. ;
Simonson, Carey J. .
APPLIED ENERGY, 2014, 127 :202-218
[9]  
Advantix Systems, 2010, CISC VIS NETW IND GL
[10]  
[Anonymous], ASHRAE T