Dosimetric analysis of intensity-modulated radiation therapy and volumetric-modulated arc therapy in comparison with conventional box technique in the treatment of carcinoma cervix: An impact of prosthetic implant

被引:2
作者
Bhushan, Manindra [1 ,2 ]
Tripathi, Deepak [2 ]
Yadav, Girigesh [1 ]
Kumar, Lalit [1 ,3 ]
Chowdhary, Rahul Lal [1 ]
Pahuja, Anjali K. [1 ]
Suhail, Mahamood [1 ]
Mitra, Swarupa [1 ]
Gairola, Munish [1 ]
机构
[1] Rajiv Gandhi Canc Inst & Res Ctr, Div Med Phys, Dept Radiat Oncol, New Delhi, India
[2] Amity Univ, Amity Sch Appl Sci, Dept Phys, Noida, Uttar Pradesh, India
[3] Dr APJ Abdul Kalam Tech Univ, Dept Appl Sci & Human, Lucknow, Uttar Pradesh, India
关键词
High-density implant; intensity-modulated radiation therapy; prosthesis; radiotherapy; volumetric-modulated arc therapy; METALLIC HIP PROSTHESES; PHOTON-BEAM ENERGY; PROSTATE-CANCER; PLAN QUALITY; RADIOTHERAPY; IRRADIATION; RAPIDARC; NUMBER; TISSUE; IMRT;
D O I
10.4103/jcrt.JCRT_835_20
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: The number of patients for carcinoma cervix with implanted hip prostheses has been increasing worldwide during the past several decades. Technological advancements are useful for delivering higher doses, i.e., dose escalation to the target, but the presence of high-density implanted hip prosthesis creates challenges for the planner. Materials and Methods: A population of 25 patients was selected for the study. Plans were generated using the MONACO treatment planning system keeping the isocenter same. The parameters evaluated for planning target volume (PTV) were D-98%, D-50%, D-2%, D-max, D-mean, V-107%, and V-110%. Similarly, the parameters D-max, D-mean, and D-2cc were evaluated for the delineated critical organs. Average monitor units (TMUmean) were also assessed. Results: D-98% of PTV was 44.51 (standard deviation [SD]: 0.13) Gy, 44.41 (SD: 0.38) Gy, 44.58 (SD: 0.14) Gy, 44.08 (SD: 0.41) Gy and 44.46 (SD: 0.32) Gy for 4F, intensity-modulated radiation therapy (IMRT), IMRT_WP, volumetric-modulated arc therapy (VMAT), and VMAT_WP techniques, respectively, where WP stands for "without prosthesis". Volume of bowel receiving 45 Gy was 86.82 (SD: 66.38) cm(3), 6.97 (SD: 5.77) cm(3), 14.11 (SD: 14.29) cm(3), 13.31 (SD: 6.57) cm(3), and 10.31 (SD: 10.94) cm(3) for 4F, IMRT, IMRT_WP, VMAT and VMAT_WP techniques, respectively. Conclusion: VMAT has an edge over other techniques in terms of target coverage and sparing of critical organs in the presence of metallic prosthesis. Information about the geometry and density of prosthesis will be beneficial for treatment planning.
引用
收藏
页码:1504 / 1512
页数:9
相关论文
共 38 条
  • [1] Alecu R, 1999, Med Dosim, V24, P33, DOI 10.1016/S0958-3947(98)00044-2
  • [2] A comparative study of RapidArc and intensity-modulated radiotherapy plan quality for cervical cancer treatment
    Atiq, Atia
    Atiq, Maria
    Iqbal, Khalid
    Sial, Manzar A.
    Altaf, Saima
    Shamsi, Quratul Ain
    Buzdar, Saeed A.
    [J]. INDIAN JOURNAL OF CANCER, 2018, 55 (01) : 74 - 79
  • [3] Bhushan M, 2019, ONCOL J INDIA, V3, P28, DOI 10.4103/oji.oji_18_19
  • [4] Dosimetric Analysis of Unflattened (FFFB) and Flattened (FB) Photon Beam Energy for Gastric Cancers Using IMRT and VMAT-a Comparative Study
    Bhushan, Manindra
    Yadav, Girigesh
    Tripathi, Deepak
    Kumar, Lalit
    Kishore, Vimal
    Dewan, Abhinav
    Kumar, Gourav
    Wahi, Inderjit Kaur
    Gairola, Munish
    [J]. JOURNAL OF GASTROINTESTINAL CANCER, 2019, 50 (03) : 408 - 419
  • [5] Calibration of CT Hounsfield units for radiotherapy treatment planning of patients with metallic hip prostheses: the use of the extended CT-scale
    Coolens, C
    Childs, PJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (11) : 1591 - 1603
  • [6] A study on beams passing through hip prosthesis for pelvic radiation treatment
    Ding, GX
    Yu, CW
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (04): : 1167 - 1175
  • [7] The effect of 6 and 15 MV on intensity-modulated radiation therapy prostate cancer treatment: plan evaluation, tumour control probability and normal tissue complication probability analysis, and the theoretical risk of secondary induced malignancies
    Hussein, M.
    Aldridge, S.
    Urbano, T. Guerrero
    Nisbet, A.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1012) : 423 - 432
  • [8] ICO/IARC Information Centre on HPV and Cancer, ICO IARC INFORM CTR
  • [9] Clinical utility of RapidArc™ radiotherapy technology
    Infusino, Erminia
    [J]. CANCER MANAGEMENT AND RESEARCH, 2015, 7 : 345 - 356
  • [10] Estimation of dose enhancement to soft tissue due to backscatter radiation near metal interfaces during head and neck radiothearpy - A phantom dosimetric study with radiochromic film
    Kinhikar, Rajesh Ashok
    Tambe, Chandrashekhar M.
    Patil, Kalpana
    Mandavkar, Mahadev
    Deshpande, Deepak D.
    Gujjalanavar, Rajendra
    Yadav, Prabha
    Budrukkar, Ashwini
    [J]. JOURNAL OF MEDICAL PHYSICS, 2014, 39 (01) : 40 - 43