A design for a compact time-of-flight mass spectrometer

被引:6
作者
Manard, Manuel J. [1 ]
机构
[1] Natl Secur Technol LLC, Special Technol Lab, Santa Barbara, CA 93111 USA
关键词
SPACE-CHARGE; ION FUNNEL; OPTIMIZATION; PRESSURE; POWER; AIR;
D O I
10.1063/1.4757864
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The design of a prototype, compact time-of-flight (TOF) mass spectrometer is described. The system primarily consists of an ion acceleration/focusing/steering assembly (AFSA), an 8 cm field-free region, a 4 cm dual-stage reflectron, and a miniature microchannel plate detector. Consequently, the resulting flight length of the system is 12 cm. The system has been designed with the capability to sample directly from atmosphere at ambient pressures. This is accomplished through the use of an electrodynamic ion funnel, housed in an intermediate-vacuum chamber that is coupled to the inlet of the TOF chamber. TOF spectra were obtained using noble gases (Ar, Kr, and Xe) as test chemicals. These measured flight times were used to probe the performance of the instrument. A temporal resolution (t(flight)/Delta t) of approximately 125, acquired using Xe-129(+), has been measured for the system. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4757864]
引用
收藏
页数:7
相关论文
共 36 条
[21]  
KOGAN VT, 1995, INSTRUM EXP TECH+, V38, P106
[22]   Miniature toroidal radio frequency ion trap mass analyzer [J].
Lammert, Stephen A. ;
Rockwood, Alan A. ;
Wang, Miao ;
Lee, Milton L. ;
Lee, Edgar D. ;
Tolley, Samuel E. ;
Oliphant, James R. ;
Jones, Jeffrey L. ;
Waite, Randall W. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2006, 17 (07) :916-922
[23]   Differential mobility spectrometry/mass spectrometry: The design of a new mass spectrometer for real-time chemical analysis in the field [J].
Manard, Manuel J. ;
Trainham, Rusty ;
Weeks, Stephan ;
Coy, Stephen L. ;
Krylov, Evgeny V. ;
Nazarov, Erkinjon G. .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2010, 295 (03) :138-144
[24]   Effect of Space Charge on Resolving Power and Ion Loss in Ion Mobility Spectrometry [J].
Mariano, Adrian V. ;
Su, Wansheng ;
Guharay, Samar K. .
ANALYTICAL CHEMISTRY, 2009, 81 (09) :3385-3391
[25]  
McLoughlin MP, 1999, J HOPKINS APL TECH D, V20, P326
[26]   A laboratory pilot for in situ analysis of refractory organic matter in Martian soil by gas chromatography-mass spectrometry [J].
Meunier, Dainein ;
Sternberg, Robert ;
Mettetal, Franck ;
Buch, Arnaud ;
Coscia, David ;
Szopa, Cyril ;
Rodier, Claude ;
Coll, Patrice ;
Cabanec, Michael ;
Raulin, Francois .
ADVANCES IN SPACE RESEARCH, 2007, 39 (03) :337-344
[27]   Desorption electrospray ionization with a portable mass spectrometer:: in situ analysis of ambient surfaces [J].
Mulligan, CC ;
Talaty, N ;
Cooks, RG .
CHEMICAL COMMUNICATIONS, 2006, (16) :1709-1711
[28]   Direct monitoring of toxic compounds in air using a portable mass spectrometer [J].
Mulligan, CC ;
Justes, DR ;
Noll, RJ ;
Sanders, NL ;
Laughlin, BC ;
Cooks, RG .
ANALYST, 2006, 131 (04) :556-567
[29]  
Shaffer SA, 1997, RAPID COMMUN MASS SP, V11, P1813
[30]   Detection and quantification of chemical plumes using a portable underwater membrane introduction mass spectrometer [J].
Short, R. T. ;
Toler, S. K. ;
Kibelka, G. P. G. ;
Roa, D. T. Rueda ;
Bell, R. J. ;
Byrne, R. H. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (07) :637-646