Timing resolution improvement using DOI information in a four-layer scintillation detector for TOF-PET

被引:32
|
作者
Shibuya, Kengo [1 ]
Nishikido, Fumihiko [1 ]
Tsuda, Tomoaki [2 ]
Kobayashi, Tetsuya [3 ]
Lam, Chihfung [1 ]
Yamaya, Taiga [1 ]
Yoshida, Eiji [1 ]
Inadama, Naoko [1 ]
Murayama, Hideo [1 ]
机构
[1] Natl Inst Radiol Sci, Mol Imaging Ctr, JPET Project Team, Inage Ku, Chiba 2630024, Japan
[2] Shimadzu Co Ltd, Technol Res Lab, Seika, Kyoto 6190237, Japan
[3] Chiba Univ, Grad Sch Engn, Dept Med Syst Engn, Inage Ku, Chiba 2638522, Japan
关键词
positron emission tomography (PET); time-of-flight (TOF); depth-of-interaction (DOI); digital sampling; timing resolution; constant fraction discrimination (CFD); TOF shift correction;
D O I
10.1016/j.nima.2008.05.020
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Depth-of-interaction (DOI) detectors are considered to be advantageous for time-of-flight positron emission tomography (TOF-PET) because they can correct timing errors arising in the scintillation crystals due to a propagation speed difference between annihilation radiation and scintillation photons. We experimentally measured this timing error, using our four-layer DOI encoding method. The upper layers exhibited the larger timing delays due to the longer path lengths after conversion from annihilation radiation into scintillation photons that traveled by zigzag paths at a speed decreased by a factor of the refractive index (n). The maximum timing delay between the uppermost and the lowermost layers was evaluated as 164 ps when n = 1.47. A TOF error correction was demonstrated to improve the timing resolution of the four-layer DOI detector by 10.3%, which would increase the effective sensitivity of the scanner by about 12% comparison with a non-DOI TOF-PET scanner. This is the first step towards combining these two important fields in PET instrumentation, namely DOI and TOF, for the purpose of achieving a higher sensitivity as well as a more uniform spatial resolution. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:572 / 577
页数:6
相关论文
共 50 条
  • [31] Analytical model of DOI-induced time bias in ultra-fast scintillation detectors for TOF-PET
    Toussaint, Maxime
    Loignon-Houle, Francis
    Dussault, Jean-Pierre
    Lecomte, Roger
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (06):
  • [32] Simplified simulation of four-layer depth of interaction detector for PET.
    Haneishi H.
    Sato M.
    Inadama N.
    Murayama H.
    Radiological Physics and Technology, 2008, 1 (1) : 106 - 114
  • [33] A four-layer depth of interaction detector block for small animal PET
    Tsuda, T
    Murayama, H
    Kitamura, K
    Yamaya, T
    Yoshida, E
    Omura, T
    Kawai, H
    Inadama, N
    Orita, N
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2537 - 2542
  • [34] Improving timing resolution of BGO for TOF-PET: a comparative analysis with and without deep learning
    Loignon-Houle, Francis
    Kratochwil, Nicolaus
    Toussaint, Maxime
    Lowis, Carsten
    Arino-Estrada, Gerard
    Gonzalez, Antonio J.
    Auffray, Etiennette
    Lecomte, Roger
    EJNMMI PHYSICS, 2025, 12 (01):
  • [35] Comparative timing measurements of LYSO and LFS to achieve the best time resolution for TOF-PET
    Doroud, K.
    Rodriguez, A.
    Williams, M. C. S.
    Zichichi, A.
    Zuyeuski, R.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [36] Evaluation of a TOF-PET detector design that achieves ≤100 ps coincidence time resolution
    Cates, J. W.
    Levin, C. S.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [37] A four-layer depth of interaction detector block for small animal PET
    Tsuda, T
    Murayama, H
    Kitamura, K
    Yamaya, T
    Yoshida, E
    Omura, T
    Kawai, H
    Inadama, N
    Orita, N
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1789 - 1793
  • [38] Simulation of a Fast Timing Micro-Pattern Gaseous Detector for TOF-PET and future accelerators
    Radogna, Raffaella
    Verwilligen, Piet
    Maggi, Marcello
    23RD INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP 2018), 2019, 214
  • [39] Signal Analysis for Improved Timing Resolution with Scintillation Detectors for TOF PET Imaging
    Wiener, R. I.
    Kaul, M.
    Surti, S.
    Karp, J. S.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1991 - 1995
  • [40] Timing measurements from a TOF-PET scanner using local PMT triggering
    Kyba, Christopher C. M.
    Wiener, Rony I.
    Newcomer, F. M.
    Van Berg, Richard
    Dressnandt, Nandor
    Karp, Joel S.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4123 - +