Timing resolution improvement using DOI information in a four-layer scintillation detector for TOF-PET

被引:32
|
作者
Shibuya, Kengo [1 ]
Nishikido, Fumihiko [1 ]
Tsuda, Tomoaki [2 ]
Kobayashi, Tetsuya [3 ]
Lam, Chihfung [1 ]
Yamaya, Taiga [1 ]
Yoshida, Eiji [1 ]
Inadama, Naoko [1 ]
Murayama, Hideo [1 ]
机构
[1] Natl Inst Radiol Sci, Mol Imaging Ctr, JPET Project Team, Inage Ku, Chiba 2630024, Japan
[2] Shimadzu Co Ltd, Technol Res Lab, Seika, Kyoto 6190237, Japan
[3] Chiba Univ, Grad Sch Engn, Dept Med Syst Engn, Inage Ku, Chiba 2638522, Japan
关键词
positron emission tomography (PET); time-of-flight (TOF); depth-of-interaction (DOI); digital sampling; timing resolution; constant fraction discrimination (CFD); TOF shift correction;
D O I
10.1016/j.nima.2008.05.020
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Depth-of-interaction (DOI) detectors are considered to be advantageous for time-of-flight positron emission tomography (TOF-PET) because they can correct timing errors arising in the scintillation crystals due to a propagation speed difference between annihilation radiation and scintillation photons. We experimentally measured this timing error, using our four-layer DOI encoding method. The upper layers exhibited the larger timing delays due to the longer path lengths after conversion from annihilation radiation into scintillation photons that traveled by zigzag paths at a speed decreased by a factor of the refractive index (n). The maximum timing delay between the uppermost and the lowermost layers was evaluated as 164 ps when n = 1.47. A TOF error correction was demonstrated to improve the timing resolution of the four-layer DOI detector by 10.3%, which would increase the effective sensitivity of the scanner by about 12% comparison with a non-DOI TOF-PET scanner. This is the first step towards combining these two important fields in PET instrumentation, namely DOI and TOF, for the purpose of achieving a higher sensitivity as well as a more uniform spatial resolution. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:572 / 577
页数:6
相关论文
共 50 条
  • [11] Optimized TOF-PET detector using scintillation crystal array for brain imaging
    Leem, Hyuntae
    Choi, Yong
    Jung, Jiwoong
    Park, Kuntai
    Kim, Yeonkyeong
    Jung, Jin Ho
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (07) : 2592 - 2598
  • [12] High Voltage Photodetector Calibration for Improved Timing Resolution with Scintillation Detectors for TOF-PET Imaging
    Davidson, Z. S.
    Wiener, R. I.
    Newcomer, F. M.
    VanBerg, R.
    Karp, J. S.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2338 - 2341
  • [13] Development of a four-layer DOI PET detector using long crystals segmented by subsurface laser engraving
    Mohammadi, Akram
    Nishikido, Fumihiko
    Inadama, Naoko
    Sakai, Toshiaki
    Yamaya, Taiga
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1056
  • [14] Monte Carlo Simulation of Four-layer DOI Detector with Relative Offset in Animal PET
    Hwang, Ji Yeon
    Lee, Seung-Jae
    Baek, Cheol-Ha
    Ito, M.
    Hong, S. J.
    Lee, J. S.
    Chung, Y. H.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3173 - +
  • [15] Monte Carlo simulation of a four-layer DOI detector with relative offset in animal PET
    Chung, Yong Hyun
    Hwang, Ji Yeon
    Baek, Cheol-Ha
    Lee, Seung-Jae
    Ito, Mikiko
    Lee, Jae Sung
    Hong, Seong Jong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 626 : 43 - 50
  • [16] Determining timing resolution from TOF-PET emission data
    Vandenberghe, S.
    Matej, S.
    Daube-Witherspoon, M. E.
    Guerchaft, M.
    Verhaeghe, J.
    Bol, A.
    van Elmbt, L.
    Lemahieu, I.
    Karp, J. S.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2727 - +
  • [17] High time-resolution MRPC detector for TOF-PET
    Liu, J.
    Wang, Y.
    Guo, B.
    Yu, Y.
    Han, D.
    Li, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1055
  • [18] Development of 1.45-mm resolution four-layer DOI–PET detector for simultaneous measurement in 3T MRI
    Nishikido F.
    Tachibana A.
    Obata T.
    Inadama N.
    Yoshida E.
    Suga M.
    Murayama H.
    Yamaya T.
    Radiological Physics and Technology, 2015, 8 (1) : 111 - 119
  • [19] Performance evaluation of a high-resolution brain PET scanner using four-layer MPPC DOI detectors
    Watanabe, Mitsuo
    Saito, Akinori
    Isobe, Takashi
    Ote, Kibo
    Yamada, Ryoko
    Moriya, Takahiro
    Omura, Tomohide
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (17): : 7148 - 7166
  • [20] Four-layer DOI detector with a multi pixel APD by light sharing method for small animal PET
    Nishikido, Fumihiko
    Inadama, Naoko
    Takahashi, Kei
    Shibuya, Kengo
    Yoshida, Eiji
    Yamaya, Taiga
    Lam, Chih Fung
    Oda, Ichiro
    Murayama, Hideo
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3681 - +