Timing resolution improvement using DOI information in a four-layer scintillation detector for TOF-PET

被引:32
|
作者
Shibuya, Kengo [1 ]
Nishikido, Fumihiko [1 ]
Tsuda, Tomoaki [2 ]
Kobayashi, Tetsuya [3 ]
Lam, Chihfung [1 ]
Yamaya, Taiga [1 ]
Yoshida, Eiji [1 ]
Inadama, Naoko [1 ]
Murayama, Hideo [1 ]
机构
[1] Natl Inst Radiol Sci, Mol Imaging Ctr, JPET Project Team, Inage Ku, Chiba 2630024, Japan
[2] Shimadzu Co Ltd, Technol Res Lab, Seika, Kyoto 6190237, Japan
[3] Chiba Univ, Grad Sch Engn, Dept Med Syst Engn, Inage Ku, Chiba 2638522, Japan
关键词
positron emission tomography (PET); time-of-flight (TOF); depth-of-interaction (DOI); digital sampling; timing resolution; constant fraction discrimination (CFD); TOF shift correction;
D O I
10.1016/j.nima.2008.05.020
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Depth-of-interaction (DOI) detectors are considered to be advantageous for time-of-flight positron emission tomography (TOF-PET) because they can correct timing errors arising in the scintillation crystals due to a propagation speed difference between annihilation radiation and scintillation photons. We experimentally measured this timing error, using our four-layer DOI encoding method. The upper layers exhibited the larger timing delays due to the longer path lengths after conversion from annihilation radiation into scintillation photons that traveled by zigzag paths at a speed decreased by a factor of the refractive index (n). The maximum timing delay between the uppermost and the lowermost layers was evaluated as 164 ps when n = 1.47. A TOF error correction was demonstrated to improve the timing resolution of the four-layer DOI detector by 10.3%, which would increase the effective sensitivity of the scanner by about 12% comparison with a non-DOI TOF-PET scanner. This is the first step towards combining these two important fields in PET instrumentation, namely DOI and TOF, for the purpose of achieving a higher sensitivity as well as a more uniform spatial resolution. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:572 / 577
页数:6
相关论文
共 50 条
  • [1] Advantage of the Four-Layer DOI Information in the Time Resolution for a TOF-PET Detector
    Tsuda, Tomoaki
    Kitamura, Keishi
    Ohi, Junichi
    Tonami, Hiromichi
    Satoh, Masanobu
    Kumazawa, Yoshihiko
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3201 - 3204
  • [2] Timing resolution improved by DOI information in an LYSO TOF-PET detector
    Shibuya, Kengo
    Nishikido, Furnihiko
    Inadama, Naoko
    Yoshida, Eiji
    Lam, Chihfung
    Tsuda, Tomoaki
    Yamaya, Taiga
    Murayama, Hideo
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3678 - 3680
  • [3] Development of a TOF-PET Detector Capable of Four-Layer DOI Encoding with a Single-Layer Crystal Array
    Tsuda, Tomoaki
    Furumiya, Tetsuo
    Ohi, Lunichi
    Tonami, Hiromichi
    Kitamura, Keishi
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3012 - 3014
  • [4] Wavelength discrimination (WLD) TOF-PET detector with DOI information
    Ullah, Muhammad Nasir
    Pratiwi, Eva
    Park, Jin Ho
    Lee, Kisung
    Choi, Hojong
    Yeom, Jung-Yeol
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (05):
  • [5] Development of a High-Resolution Four-Layer DOI Detector Using MPPCs for Brain PET
    Omura, T.
    Moriya, T.
    Yamada, R.
    Yamauchi, H.
    Saito, A.
    Sakai, T.
    Miwa, T.
    Watanabe, M.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3560 - 3563
  • [6] Timing Resolution Improvement of MPPC for TOF-PET Imaging
    Nagano, T.
    Sato, K.
    Ishida, A.
    Baba, T.
    Tsuchiya, R.
    Yamamoto, K.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 1577 - 1580
  • [7] Four-layer DOI detector with a relative offset in animal PET system
    Ito, Mikiko
    Hong, Seong Jong
    Lee, Jae Sung
    Kwon, Sun Il
    Lee, Geon Song
    Park, Kwang Suk
    Hong, Byungsik
    Lee, Kyong Sei
    Lee, Seok Jae
    Rhee, June Tak
    Sim, Kwang-Souk
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4296 - +
  • [8] Four-layer DOI-PET detector with a silicon photomultiplier array
    Nishikido, Fumihiko
    Inadama, Naoko
    Shibuya, Kengo
    Yoshida, Eiji
    Yamaya, Taiga
    Oda, Ichiro
    Kitamura, Keishi
    Murayama, Hideo
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3198 - +
  • [9] Preliminary evaluation of four-layer BGO DOI-detector for PET
    Inadama, N
    Murayama, H
    Yamaya, T
    Kitamura, K
    Yamashita, T
    Kawai, H
    Tsuda, T
    Sato, M
    Ono, Y
    Hamamoto, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) : 30 - 34
  • [10] A Four-Layer DOI Detector With a Relative Offset for Use in an Animal PET System
    Ito, Mikiko
    Lee, Jae Sung
    Kwon, Sun Il
    Lee, Geon Song
    Hong, Byungsik
    Lee, Kyong Sei
    Sim, Kwang-Souk
    Lee, Seok Jae
    Rhee, June Tak
    Hong, Seong Jong
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (03) : 976 - 981