Comparison of Real Time Two-Dimensional with Live/Real Time Three-Dimensional Transesophageal Echocardiography in the Evaluation of Mitral Valve Prolapse and Chordae Rupture

被引:48
|
作者
Manda, Jayaprakash
Kesanolla, Saritha Kumari
Hsuing, Ming Chon [2 ]
Nanda, Navin C. [1 ]
Abo-Salem, Elsayed
Dutta, Rajarshi
Laney, Charles Allen
Wei, Jeng [2 ]
Chang, Chung-Yi [2 ]
Tsai, Shen-Kou
Hansalia, Sachin
Yin, Wei-Hsian [2 ]
Young, Mason S. [2 ]
机构
[1] Univ Alabama, Heart Stn SWB S102, Div Cardiovasc Dis, Birmingham, AL 35249 USA
[2] Cheng Hsin Med Ctr, Div Cardiovasc Dis, Taipei, Taiwan
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2008年 / 25卷 / 10期
关键词
mitral valve prolapse; mitral valve chordae rupture; three-dimensional transesophageal echocardiography; two-dimensional transesophageal echocardiography;
D O I
10.1111/j.1540-8175.2008.00832.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We compared live/real time three-dimensional transesophageal echocardiography (3D TEE) with real time two-dimensional transesophageal echocardiography (2D TEE) in the assessment of individual mitral valve (MV) segment/scallop prolapse and associated chordae rupture in 18 adult patients with a flail MV undergoing surgery for mitral regurgitation. 2D TEE was able to diagnose the prolapsing segment/scallop and associated chordae rupture correctly in only 9 of 18 patients when compared to surgery. In three of these, 2D TEE diagnosed an additional segment/scallop not confirmed at surgery. In the remaining nine patients, surgical findings were missed by 2D TEE. On the other hand with 3D TEE, the prolapsed segment/scallop and associated ruptured chords correlated exactly with the surgical findings in the operating room in 16 of 18 patients. The exceptions were two patients. In one, 3D TEE diagnosed prolapse and ruptured chordae of the A3 segment and P3 scallop, while the surgical finding was chordae rupture of the A3 segment but only prolapse without chordae rupture of the P3 scallop. In the other patient, 3D TEE diagnosed prolapse and chordae rupture of P1 scallop and prolapse without chordae rupture of the A1 and A2 segments, while at surgery chordae rupture involved A1, A2, and P1. This preliminary study demonstrates the superiority of 3D TEE over 2D TEE in the evaluation of individual MV segment/scallop prolapse and associated ruptured chordae. (ECHOCARDIOGRAPHY, Volume 25, November 2008)
引用
收藏
页码:1131 / 1137
页数:7
相关论文
共 50 条
  • [1] Preoperative Assessment of Mitral Valve Prolapse and Chordae Rupture Using Real Time Three-Dimensional Transesophageal Echocardiography
    Chen, Xin
    Sun, Dandan
    Yang, Jun
    Feng, Wei
    Gu, Tianxiang
    Zhang, Zhiwei
    Xiu, Zongyi
    Tang, Li
    Ma, Chunyan
    Wang, Xiaobing
    Cheng, Yanbin
    Li, Nan
    Liu, Shuang
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2011, 28 (09): : 1003 - 1010
  • [2] Live/Real Time Three-Dimensional Transesophageal Echocardiography
    Sudhakar, Selvin
    Khairnar, Prakash
    Nanda, Navin C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (01): : 103 - 111
  • [3] Depicting of a Cleft Mitral Valve by Real Time Three-Dimensional Transesophageal Echocardiography
    Ozkan, Mehmet
    Kaya, Hasan
    Duran, Niluefer Eksi
    Biteker, Murat
    Avci, Anil
    Yildiz, Mustafa
    Tuncer, Altug
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2010, 27 (03): : 356 - 358
  • [4] Evaluation of a Posterior Mitral Valve Leaflet Aneurysm by Real Time Three-Dimensional Transesophageal Echocardiography
    Hong, Susie N.
    Perk, Gila
    Skolnick, Adam
    Kronzon, Itzhak
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2009, 26 (09): : 1089 - 1091
  • [5] Initial experience with Live/Real time three-dimensional transesophageal echocardiography
    Pothineni, Koteswara R.
    Inamdar, Vatsal
    Andrew, P. Miller
    Nanda, Navin C.
    Bandarupalli, Naveen
    Chaurasia, Preeti
    James, K. Kirklin
    McGiffin, David C.
    Pajaro, Octavio E.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2007, 24 (10): : 1099 - 1104
  • [6] Impact of real-time three-dimensional transesophageal echocardiography on procedural success for mitral valve repair
    Mori M.
    Yoshimuta T.
    Ohira M.
    Yagi M.
    Sakata K.
    Konno T.
    Kawashiri M.-A.
    Tomita S.
    Watanabe G.
    Iino K.
    Takemura H.
    Yamagishi M.
    Hayashi K.
    Journal of Echocardiography, 2015, 13 (3) : 100 - 106
  • [7] Incremental Value of Live/Real Time Three-Dimensional over Two-Dimensional Transesophageal Echocardiography in the Assessment of Atrial Septal Pouch
    Elsayed, Mahmoud
    Hsiung, Ming C.
    Meggo-Quiroz, L. David
    Elguindy, Mostafa
    Uygur, Begum
    Tandon, Rohit
    Guvenc, Tolga
    Keser, Nurgul
    Vural, Mustafa G.
    Bulur, Serkan
    Chahwala, Jugal R.
    Abtahi, Firoozeh
    Nanda, Navin C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (12): : 1858 - 1867
  • [8] Incremental Value of Live/Real Time Three-Dimensional Transesophageal Echocardiography over the Two-Dimensional Modality in the Assessment of Cardiac Lymphoma
    Thind, Munveer
    Hsiung, Ming C.
    Gok, Gulay
    Elsayed, Mahmoud
    Joson, Marisa
    Nanda, Navin C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (04): : 671 - 676
  • [9] Live/Real Time Three-Dimensional Transesophageal Echocardiographic Evaluation of Mitral and Aortic Valve Prosthetic Paravalvular Regurgitation
    Singh, Preeti
    Manda, Jayaprakash
    Hsiung, Ming Chon
    Mehta, Anjlee
    Kesanolla, Saritha Kumari
    Nanda, Navin C.
    Tsai, Shen-Kou
    Jeng-Wei
    Yin, Wei-Hsian
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2009, 26 (08): : 980 - 987
  • [10] Incremental Value of Live/Real Time Three-Dimensional over Two-Dimensional Transesophageal Echocardiography in the Evaluation of Right Coronary Artery Fistula
    Mishra, Jaymala
    Puri, Hari Prakash
    Hsiung, Ming C.
    Misra, Stuti
    Khairnar, Prakash
    Gollamudi, Bhargavi Laxmi
    Patel, Adilahmed
    Nanda, Navin C.
    Yin, Wei-Hsian
    Wei, Jeng
    Tsai, Shen-Kou
    Sudhakar, Selvin
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2011, 28 (07): : 805 - 808