Multi-stir bar sorptive extraction for analysis of odor compounds in aqueous samples

被引:46
作者
Ochiai, Nobuo [1 ]
Sasamoto, Kikuo [1 ]
Ieda, Teruyo [1 ]
David, Frank [2 ]
Sandra, Pat [2 ]
机构
[1] GERSTEL KK, Meguro Ku, Tokyo 1520031, Japan
[2] Res Inst Chromatog, B-8500 Kortrijk, Belgium
关键词
Multi-SBSE ((SBSE)-S-m); EG Silicone stir bar; PDMS stir bar; Thermal desorption; GC-MS; Odor analysis; PERSONAL CARE PRODUCTS; LIQUID-CHROMATOGRAPHY; MONOLITHIC MATERIAL; GC-MS; COATINGS; WATER;
D O I
10.1016/j.chroma.2013.09.070
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
As reproducible coating of stir bars with more polar phases was found to be very difficult, a supporting grid was used in the development of an ethyleneglycol-modified Silicone (EG Silicone) coated stir bar. This new polar coating showed good performance for the extraction of polar solutes, but long term use also showed degradation of the coating due to friction while stirring. In order to address the lower robustness of the EG Silicone stir bar which has a much softer coating compared to a conventional polydimethylsiloxane (PDMS) stir bar, a novel SBSE procedure termed multi-SBSE ((SBSE)-S-m) was developed. (SBSE)-S-m consists of the robust PDMS stir bar stirring at the bottom of the vial and the EG Silicone stir bar attached on the inner side wall of the vial (a magnetic clip is used for the set-up). After extraction, the two stir bars are placed in a single glass desorption liner and are simultaneously thermally desorbed. The desorbed compounds were analyzed by thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS). Compared to conventional SBSE, (SBSE)-S-m provides more uniform enrichment of a wide range of odor compounds in aqueous sample since both stir bars can complement each other, while eliminating the damage of the EG Silicone phase during the extraction. The robustness of the EG Silicone stir bar was dramatically increased and more than 30 extraction and desorption cycles were possible without loss in performance. The recoveries for polar solutes such as 2-acetyl pyrrole (log K-ow: 0.55), benzyl alcohol (log K-ow : 1.08), guaiacol (log K-ow: 1.34), and indole (log K-ow: 2.05) were increased by a factor of about 2-7. The (SBSE)-S-m-TD-GC-MS method showed good linearity (r(2) > 0.9913) and high sensitivity (limit of detection: 0.011-0.071 ng mL(-1)) for the test compounds spiked in water. The feasibility and benefit of the method was demonstrated with analysis of odor compounds in roasted green tea. The normalized areas obtained from mSBSE showed the best enrichment for most of the selected compounds compared to conventional SBSE using the PDMS stir bar or the EG Silicone stir bar. Fifteen compounds were determined in the range of 0.15-210 ng mL(-1) (RSD < 14%, n = 6). (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:70 / 79
页数:10
相关论文
共 21 条
  • [1] SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS
    ARTHUR, CL
    PAWLISZYN, J
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (19) : 2145 - 2148
  • [2] Baltussen E, 1999, J MICROCOLUMN SEP, V11, P737, DOI 10.1002/(SICI)1520-667X(1999)11:10<737::AID-MCS7>3.0.CO
  • [3] 2-4
  • [4] Dual-phase twisters: A new approach to headspace sorptive extraction and stir bar sorptive extraction
    Bicchi, C
    Cordero, C
    Liberto, E
    Rubiolo, P
    Sgorbini, B
    David, F
    Sandra, P
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1094 (1-2) : 9 - 16
  • [5] Bicchi C., 2009, LC GC N AM, P376
  • [6] Stir bar sorptive extraction for trace analysis
    David, Frank
    Sandra, Pat
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1152 (1-2) : 54 - 69
  • [7] Novel coatings for stir bar sorptive extraction to determine pharmaceuticals and personal care products in environmental waters by liquid chromatography and tandem mass spectrometry
    Gilart, Nuria
    Miralles, Nuria
    Maria Marce, Rosa
    Borrull, Francesc
    Fontanals, Nuria
    [J]. ANALYTICA CHIMICA ACTA, 2013, 774 : 51 - 60
  • [8] Direct enrichment of phenols in lake and sea water by stir bar sorptive extraction based on poly (vinylpyridine-ethylene dimethacrylate) monolithic material and liquid chromatographic analysis
    Huang, Xiaojia
    Qiu, Ningning
    Yuan, Dongxing
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1194 (01) : 134 - 138
  • [9] Determination of steroid sex hormones in urine matrix by stir bar sorptive extraction based on monolithic material and liquid chromatography with diode array detection
    Huang, Xiaojia
    Yuan, Dongxing
    Huang, Benli
    [J]. TALANTA, 2008, 75 (01) : 172 - 177
  • [10] Stir bar sorptive extraction with EG-Silicone coating for bisphenols determination in personal care products by GC-MS
    Ignacio Cacho, Juan
    Campillo, Natalia
    Vinas, Pilar
    Hernandez-Cordoba, Manuel
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 78-79 : 255 - 260