STATIC BEHAVIOR OF LONG-SPAN RC CABLE-STAYED BRIDGE WITH FRP CABLES

被引:0
|
作者
Wang, Xin [1 ]
Zeng, Fan-Xing [1 ]
Wu, Zhi-Shen [1 ]
机构
[1] Southeast Univ, Sch Civil Engn, Int Inst Urban Syst Engn, Nanjing 210096, Jiangsu, Peoples R China
来源
INNOVATION & SUSTAINABILITY OF STRUCTURES, VOLS 1 AND 2 | 2011年
关键词
FRP cable; hybrid design; cable-stayed bridge; cable design;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Based on previous studies of thousand-meter scale cable-stayed bridge with FRP cables, the design method of cables and the static behavior of FRP long-span RC cable-stayed bridge are further investigated in this paper, which focuses on the limitation of insufficient use of FRP cables and potential extension of their applicable spans. The static and fatigue properties of FRP cables were first experimental studied, based on which design method aiming at high-efficiency use was proposed. A three-dimensional finite element simulation was adopted to study the static behavior of RC cable-stayed bridge with different FRP cable including carbon FRP (CFRP), basalt FRP (BFRP), hybrid basalt and carbon FRP (B/CFRP) and basalt and steel-wire FRP (B/SFRP). The major results show that (1) hybrid design of FRP can enhance the integrated behavior of FRP and obtain mechanical behavior required by cable-stayed bridge; (2) the design stress of FRP cable determined by fatigue strength benefits improving of the utilization efficiency and overcoming the limitation of strength and stiffness equivalent design methods; (3) compared to RC cable stayed bridge with steel cables, cable-stayed bridges with FRP cables exhibit sufficient stiffness under the state of serviceability and cause slight influence to the structural behavior of main girder.
引用
收藏
页码:957 / 964
页数:8
相关论文
共 50 条
  • [1] Static and Dynamic Characteristics of a Long-Span Cable-Stayed Bridge with CFRP Cables
    Xie, Xu
    Li, Xiaozhang
    Shen, Yonggang
    MATERIALS, 2014, 7 (06) : 4854 - 4877
  • [2] Fatigue life assessment of FRP cable for long-span cable-stayed bridge
    Feng, Bo
    Wang, Xin
    Wu, Zhishen
    COMPOSITE STRUCTURES, 2019, 210 : 159 - 166
  • [3] Evaluation of FRP and hybrid FRP cables for super long-span cable-stayed bridges
    Wang, Xin
    Wu, Zhishen
    COMPOSITE STRUCTURES, 2010, 92 (10) : 2582 - 2590
  • [4] VIBRATION CONTROL OF DIFFERENT FRP CABLES IN LONG-SPAN CABLE-STAYED BRIDGE UNDER INDIRECT EXCITATIONS
    Wang, Xin
    Wu, Zhishen
    JOURNAL OF EARTHQUAKE AND TSUNAMI, 2011, 5 (02) : 167 - 188
  • [5] Dynamic Characteristics of a Long-span Cable-stayed Bridge
    Hui, Liu
    MATERIALS ENGINEERING FOR ADVANCED TECHNOLOGIES, PTS 1 AND 2, 2011, 480-481 : 1496 - 1501
  • [6] Damage Detection for Long-Span Cable-Stayed Bridge
    赵玲
    李爱群
    缪长青
    汪永兰
    Journal of Southwest Jiaotong University, 2006, (01) : 63 - 72
  • [7] THE INFLUENCE OF BROKEN CABLES ON THE STRUCTURAL BEHAVIOR OF LONG-SPAN CABLE-STAYED BRIDGES
    Kao, Chin-Sheng
    Kou, Chang-Huan
    JOURNAL OF MARINE SCIENCE AND TECHNOLOGY-TAIWAN, 2010, 18 (03): : 395 - 404
  • [8] Progressive Collapse Behavior of a Long-Span Cable-Stayed Bridge Induced by Cable Loss
    Chen, Qian
    Wang, Hongfan
    El-Tawil, Sherif
    Agrawal, Anil K.
    Bhattacharya, Baidurya
    Wong, Waider
    JOURNAL OF BRIDGE ENGINEERING, 2023, 28 (09)
  • [9] RESEARCH ON THE ASEISMIC BEHAVIOR OF LONG-SPAN CABLE-STAYED BRIDGE WITH DAMPING EFFECT
    Wu Fangwen
    Zhang Qingkai
    Feng Binglong
    Qiu Jiantao
    CIVIL ENGINEERING JOURNAL-STAVEBNI OBZOR, 2016, 25 (02):
  • [10] Instrumentation for durability monitoring of a long-span cable-stayed bridge
    Hua, XG
    Ni, YQ
    Zhou, HF
    Ko, JM
    Smart Structures and Materials 2005: Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace, Pts 1 and 2, 2005, 5765 : 982 - 991