A Static Voltage Security Region for Centralized Wind Power Integration-Part II: Applications

被引:13
作者
Ding, Tao [1 ]
Guo, Qinglai [1 ]
Bo, Rui [2 ]
Sun, Hongbin [1 ]
Zhang, Boming [1 ]
Huang, Tian-en [1 ]
机构
[1] Tsinghua Univ, Dept Elect Engn, State Key Lab Power Syst, Beijing 100084, Peoples R China
[2] Midwest Independent Transmiss Syst Operator Midwe, St Paul, MN 55108 USA
来源
ENERGIES | 2014年 / 7卷 / 01期
基金
美国国家科学基金会;
关键词
wind power; voltage security region; inner point; near point; optimization; Monte Carlo simulation; N-1; contingency; cascading tripping; SYSTEM; OPERATION;
D O I
10.3390/en7010444
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In Part I of this work, a static voltage security region was introduced to guarantee the safety of wind farm reactive power outputs under both base conditions and N-1 contingency. In this paper, a mathematical representation of the approximate N-1 security region has further studied to provide better coordination among wind farms and help prevent cascading tripping following a single wind farm trip. Besides, the influence of active power on the security region is studied. The proposed methods are demonstrated for N-1 contingency cases in a nine-bus system. The simulations verify that the N-1 security region is a small subset of the security region under base conditions. They also illustrate the fact that if the system is simply operated below the reactive power limits, without coordination among the wind farms, the static voltage is likely to exceed its limit. A two-step optimal adjustment strategy is introduced to shift insecure operating points into the security region under N-1 contingency. Through extensive numerical studies, the effectiveness of the proposed technique is confirmed.
引用
收藏
页码:444 / 461
页数:18
相关论文
共 20 条
[1]   A large wind power system in almost island operation - A Danish case study [J].
Akhmatov, Vladislav ;
Eniksen, Peter Borre .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2007, 22 (03) :937-943
[2]   New Approaches for Very Short-term Steady-State Analysis of An Electrical Distribution System with Wind Farms [J].
Bracale, Antonio ;
Carpinelli, Guido ;
Proto, Daniela ;
Russo, Angela ;
Varilone, Pietro .
ENERGIES, 2010, 3 (04) :650-670
[3]   Control Algorithm for Coordinated Reactive Power Compensation in a Wind Park [J].
Diaz-Dorado, E. ;
Carrillo, C. ;
Cidras, J. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2008, 23 (04) :1064-1072
[4]   A Static Voltage Security Region for Centralized Wind Power Integration-Part I: Concept and Method [J].
Ding, Tao ;
Guo, Qinglai ;
Bo, Rui ;
Sun, Hongbin ;
Zhang, Boming .
ENERGIES, 2014, 7 (01) :420-443
[5]   Optimal Voltage Control of PJM Smart Transmission Grid: Study, Implementation, and Evaluation [J].
Guo, Qinglai ;
Sun, Hongbin ;
Zhang, Mingye ;
Tong, Jianzhong ;
Zhang, Boming ;
Wang, Bin .
IEEE TRANSACTIONS ON SMART GRID, 2013, 4 (03) :1665-1674
[6]  
Heredia E., 2013, P IEEE POW EN SOC GE, P1
[7]   Reinforced Control and Operation of DFIG-Based Wind-Power-Generation System Under Unbalanced Grid Voltage Conditions [J].
Hu, Jiabing ;
He, Yikang .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2009, 24 (04) :905-915
[8]   Impacts of Large Scale Wind Penetration on Energy Supply Industry [J].
Kabouris, John ;
Kanellos, Fotis D. .
ENERGIES, 2009, 2 (04) :1031-1041
[9]   Extended Reactive Capability of DFIG Wind Parks for Enhanced System Performance [J].
Konopinski, Ryan J. ;
Vijayan, Pradip ;
Ajjarapu, Venkataramana .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2009, 24 (03) :1346-1355
[10]  
Liu Y., 2013, P 2013 IEEE GREN POW