Evaluation of the Pentacam Ray Tracing Method for the Measurement of Central Corneal Power After Myopic Photorefractive Keratectomy

被引:28
作者
Oh, Jong-Hyun [1 ]
Kim, Sung Hyun [1 ]
Chuck, Roy S. [2 ]
Park, Choul Yong [1 ]
机构
[1] Dongguk Univ, Ilsan Hosp, Dept Ophthalmol, Goyang 410773, Kyunggi Do, South Korea
[2] Montefiore Med Ctr, Albert Einstein Coll Med, Dept Ophthalmol & Visual Sci, Bronx, NY 10467 USA
基金
新加坡国家研究基金会;
关键词
keratometry; myopia; PRK; LASIK; Scheimpflug; TCRP; EXCIMER-LASER SURGERY; REFRACTIVE SURGERY; EYES;
D O I
10.1097/ICO.0000000000000034
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:The study evaluated the ray tracing method [total corneal refractive power (TCRP)] in a Pentacam apparatus (Oculus, Wetzlar, Germany) for postoperative keratometry measurement after myopic photorefractive keratectomy (PRK).Methods:Manifest refraction (MR) and Pentacam analyses were performed preoperatively and at 6 months postoperatively after the PRK (STAR S4 IR CustomVue; Abbott Medical Optics/Visx) in 49 right eyes from 49 patients (age, 25.42 3.51 years). Postoperative corneal power was calculated using the clinical history method (CHM) and compared with postoperatively measured simulated keratometry (simK), true net power (TNP) at 3 mm, and pupil-centered TCRP at the center, 1, 3, and 4 mm (TCRP0, TCRP1, TCRP3, and TCRP4). Vertex-distance-adjusted refractive change (delta-MR) at the corneal plane was also compared with various keratometric changes (delta-K).Results:Postoperative TCRP0, TCRP1, TCRP3, and TCRP4 showed no significant difference compared with that of the CHM. Postoperative simK was significantly higher than that of the CHM, whereas the TNP was significantly lower compared with that of the CHM. The delta-Ks measured by simK, TNP, and TCRPs were significantly smaller than delta-MR, and delta-TCRP4 showed the least difference [mean +/- SD, 0.28 +/- 0.55 diopters (D)] with delta-MR. The 95% limit of agreement between delta-MR and delta-TCRP4 was -0.85 to 1.31 D. The difference between delta-TCRP4 and delta-MR was <0.5 D in 55.1% and <1.0 D in 87.8% of the eyes studied.Conclusions:Although postoperative TCRPs showed no significant difference with CHM, delta-MR was still underestimated after myopic PRK.
引用
收藏
页码:261 / 265
页数:5
相关论文
共 44 条
  • [41] A Comparative Study of Total Corneal Power Using a Ray Tracing Method Obtained from 3 Different Scheimpflug Camera Devices
    Pan, Chao
    Tan, Weina
    Savini, Giacomo
    Hua, Yanjun
    Ye, Xiuhong
    Xu, Wenjin
    Yu, Jinjin
    Wang, Qinmei
    Huang, Jinhai
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 216 : 90 - 98
  • [42] Development of a New Method for Calculating Intraocular Lens Power after Myopic Laser In Situ Keratomileusis by Combining the Anterior-Posterior Ratio of the Corneal Radius of the Curvature with the Double-K Method
    Iida, Yoshihiko
    Shimizu, Kimiya
    Shoji, Nobuyuki
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (03)
  • [43] Corneal power measurements by ray tracing in eyes after small incision lenticule extraction for myopia with a combined Scheimpflug Camera–Placido disk topographer
    Mª Victoria de Rojas Silva
    Adrián Tobío Ruibal
    Jorge Suanzes Hernández
    International Ophthalmology, 2022, 42 : 921 - 931
  • [44] Pilot evaluation of refractive prediction errors associated with a new method for ray-tracing-based intraocular lens power calculation
    Hirnschall, Nino
    Buehren, Tobias
    Trost, Micheal
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (06) : 738 - 744