Multicenter validation of the VITEK MS v2.0 MALDI-TOF mass spectrometry system for the identification of fastidious gram-negative bacteria

被引:29
作者
Branda, John A. [1 ,2 ]
Rychert, Jenna [1 ,2 ]
Burnham, Carey-Ann D. [4 ]
Bythrow, Maureen [5 ]
Garner, Omai B.
Ginocchio, Christine C. [5 ,6 ]
Jennemann, Rebecca [3 ]
Lewinski, Michael A. [7 ]
Manji, Ryhana [5 ]
Mochon, A. Brian [7 ]
Procop, Gary W. [8 ]
Richter, Sandra S. [8 ]
Sercia, Linda F. [8 ]
Westblade, Lars F. [3 ,4 ,6 ]
Ferraro, Mary Jane [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Pathol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Barnes Jewish Hosp, St Louis, MO 63110 USA
[4] Washington Univ, Sch Med, Dept Pathol & Immunol, St Louis, MO USA
[5] Dept Pathol & Lab Med, North Shore LIJ Hlth Syst Labs, Lake Success, NY USA
[6] Hofstra North Shore LIJ Sch Med, Dept Pathol & Lab Med, Hempstead, NY USA
[7] Univ Calif Los Angeles, David Geffen Sch Med, Dept Pathol & Lab Med, Los Angeles, CA 90095 USA
[8] Cleveland Clin, Dept Clin Pathol, Cleveland, OH 44106 USA
关键词
MALDI-TOF MS; Fastidious; Gram-negative bacilli; Identification; VITEK; DESORPTION IONIZATION-TIME; NEISSERIA; HAEMOPHILUS;
D O I
10.1016/j.diagmicrobio.2013.08.013
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
The VITEK MS v2.0 MALDI-TOF mass spectrometry system's performance in identifying fastidious gram-negative bacteria was evaluated in a multicenter study. Compared with the reference method (DNA sequencing), the VITEK MS system provided an accurate, species-level identification for 96% of 226 isolates; an additional 1% were accurately identified to the genus level. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:129 / 131
页数:3
相关论文
共 20 条
[1]   Evaluation of commercial kits for the identification of Neisseria gonorrhoeae [J].
Alexander, S ;
Ison, C .
JOURNAL OF MEDICAL MICROBIOLOGY, 2005, 54 (09) :827-831
[2]  
Alias B., 2013, CLIN MANIFESTATIONS
[3]  
BARBE G, 1994, J CLIN MICROBIOL, V32, P187
[4]   Identification of Campylobacter species and related organisms by matrix assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry [J].
Bessede, E. ;
Solecki, O. ;
Sifre, E. ;
Labadi, L. ;
Megraud, F. .
CLINICAL MICROBIOLOGY AND INFECTION, 2011, 17 (11) :1735-1739
[5]   Use of MALDI-TOF mass spectrometry for identification of bacteria that are difficult to culture [J].
Biswas, Silpak ;
Rolain, Jean-Marc .
JOURNAL OF MICROBIOLOGICAL METHODS, 2013, 92 (01) :14-24
[6]   Identification of HACEK Clinical Isolates by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry [J].
Couturier, Marc Roger ;
Mehinovic, Elvina ;
Croft, Ann C. ;
Fisher, Mark A. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (03) :1104-1106
[7]  
Elias J., 2011, Manual of clinical microbiology, V10th, P559
[8]  
Fitzgerald C., 2011, Manual of Clinical Microbiology, V10th, P885, DOI DOI 10.1128/9781555816728.CH53
[9]   Rapid and cost-effective identification of Bartonella species using mass spectrometry [J].
Fournier, Pierre-Edouard ;
Couderc, Carine ;
Buffet, Sylvain ;
Flaudrops, Christophe ;
Raoult, Didier .
JOURNAL OF MEDICAL MICROBIOLOGY, 2009, 58 (09) :1154-1159
[10]   IDENTIFICATION OF NEISSERIA SPP, HEMOPHILUS SPP, AND OTHER FASTIDIOUS GRAM-NEGATIVE BACTERIA WITH THE MICROSCAN HAEMOPHILUS-NEISSERIA IDENTIFICATION PANEL [J].
JANDA, WM ;
BRADNA, JJ ;
RUTHER, P .
JOURNAL OF CLINICAL MICROBIOLOGY, 1989, 27 (05) :869-873