Semiautomatic three-dimensional CT ventricular volumetry in patients with congenital heart disease: agreement between two methods with different user interaction

被引:25
作者
Goo, Hyun Woo [1 ,2 ]
Park, Sang-Hyub [1 ,2 ]
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiol, Seoul, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Res Inst Radiol, Seoul, South Korea
关键词
Multi-detector row CT; Comparative study; Ventricular volumetry; Congenital heart disease; Cardiac CT; SOURCE COMPUTED-TOMOGRAPHY; DUAL-SOURCE; PAPILLARY-MUSCLES; CARDIAC-FUNCTION; IMPACT; SEGMENTATION; TRABECULAE; QUANTIFICATION; CHILDREN; INFANT;
D O I
10.1007/s10554-015-0751-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To assess agreement between two semi-automatic, three-dimensional (3D) computed tomography (CT) ventricular volumetry methods with different user interactions in patients with congenital heart disease. In 30 patients with congenital heart disease (median age 8 years, range 5 days-33 years; 20 men), dual-source, multi-section, electrocardiography-synchronized cardiac CT was obtained at the end-systolic (n = 22) and/or end-diastolic (n = 28) phase. Nineteen left ventricle end-systolic (LV ESV), 28 left ventricle end-diastolic (LV EDV), 22 right ventricle end-systolic (RV ESV), and 28 right ventricle end-diastolic volumes (RV EDV) were successfully calculated using two semi-automatic, 3D segmentation methods with different user interactions (high in method 1, low in method 2). The calculated ventricular volumes of the two methods were compared and correlated. A P value < 0.05 was considered statistically significant. LV ESV (35.95 +/- A 23.49 ml), LV EDV (88.76 +/- A 61.83 ml), and RV ESV (46.87 +/- A 47.39 ml) measured by method 2 were slightly but significantly smaller than those measured by method 1 (41.25 +/- A 26.94 ml, 92.20 +/- A 62.69 ml, 53.61 +/- A 50.08 ml for LV ESV, LV EDV, and RV ESV, respectively; P a parts per thousand currency sign 0.02). In contrast, no statistically significant difference in RV EDV (122.57 +/- A 88.57 ml in method 1, 123.83 +/- A 89.89 ml in method 2; P = 0.36) was found between the two methods. All ventricular volumes showed very high correlation (R = 0.978, 0.993, 0.985, 0.997 for LV ESV, LV EDV, RV ESV, and RV EDV, respectively; P < 0.001) between the two methods. In patients with congenital heart disease, 3D CT ventricular volumetry shows good agreement and high correlation between the two methods, but method 2 tends to slightly underestimate LV ESV, LV EDV, and RV ESV.
引用
收藏
页码:223 / 232
页数:10
相关论文
共 27 条
[1]   Cardiac Function by MRI in Congenital Heart Disease: Impact of Consensus Training on Interinstitutional Variance [J].
Beerbaum, Philipp ;
Barth, Peter ;
Kropf, Siegfried ;
Sarikouch, Samir ;
Kelter-Kloepping, Andrea ;
Franke, Diana ;
Gutberlet, Matthias ;
Kuehne, Titus .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (05) :956-966
[2]   Correlation of Trabeculae and Papillary Muscles With Clinical and Cardiac Characteristics and Impact on CMR Measures of LV Anatomy and Function [J].
Chuang, Michael L. ;
Gona, Philimon ;
Hautvast, Gilion L. T. F. ;
Salton, Carol J. ;
Blease, Susan J. ;
Yeon, Susan B. ;
Breeuwer, Marcel ;
O'Donnell, Christopher J. ;
Manning, Warren J. .
JACC-CARDIOVASCULAR IMAGING, 2012, 5 (11) :1115-1123
[3]   Left ventricle: Automated segmentation by using myocardial effusion threshold reduction and Intravoxel Computation at MR imaging [J].
Codella, Noel C. F. ;
Weinsaft, Jonathan W. ;
Cham, Matthew D. ;
Janik, Matthew ;
Prince, Martin R. ;
Wang, Yi .
RADIOLOGY, 2008, 248 (03) :1004-1012
[4]   Improved Left Ventricular Mass Quantification With Partial Voxel Interpolation In Vivo and Necropsy Validation of a Novel Cardiac MRI Segmentation Algorithm [J].
Codella, Noel C. F. ;
Lee, Hae Yeoun ;
Fieno, David S. ;
Chen, Debbie W. ;
Hurtado-Rua, Sandra ;
Kochar, Minisha ;
Finn, John Paul ;
Judd, Robert ;
Goyal, Parag ;
Schenendorf, Jesse ;
Cham, Matthew D. ;
Devereux, Richard B. ;
Prince, Martin ;
Wang, Yi ;
Weinsaft, Jonathan W. .
CIRCULATION-CARDIOVASCULAR IMAGING, 2012, 5 (01) :137-146
[5]   Semi-automatic measurement of left ventricular function on dual source computed tomography using five different software tools in comparison with magnetic resonance imaging [J].
de Jonge, G. J. ;
van der Vleuten, P. A. ;
Overbosch, J. ;
Lubbers, D. D. ;
Jansen-van der Weide, M. C. ;
Zijlstra, F. ;
van Ooijen, P. M. A. ;
Oudkerk, M. .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (03) :755-766
[6]   Comparison of (semi-)automatic and manually adjusted measurements of left ventricular function in dual source computed tomography using three different software tools [J].
de Jonge, G. J. ;
van Ooijen, P. M. A. ;
Overbosch, J. ;
Litcheva Gueorguieva, A. ;
Janssen-van der Weide, M. C. ;
Oudkerk, M. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (06) :787-794
[7]   Impact of right ventricular endocardial trabeculae on volumes and function assessed by CMR in patients with tetralogy of Fallot [J].
Freling, Hendrik G. ;
van Wijk, Kees ;
Jaspers, Karolien ;
Pieper, Petronella G. ;
Vermeulen, Karin M. ;
van Swieten, Jeroen M. ;
Willems, Tineke P. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (03) :625-631
[8]   Left ventricular noncompaction in an infant: use of non-ECG-gated cardiac CT [J].
Goo, Hyun Woo ;
Park, In-Sook .
PEDIATRIC RADIOLOGY, 2007, 37 (02) :217-220
[9]   Current trends in cardiac CT in children [J].
Goo, Hyun Woo .
ACTA RADIOLOGICA, 2013, 54 (09) :1055-1062
[10]   CT Radiation Dose Optimization and Estimation: an Update for Radiologists [J].
Goo, Hyun Woo .
KOREAN JOURNAL OF RADIOLOGY, 2012, 13 (01) :1-11