Is micro-computed tomography reliable to determine the microstructure of the maxillary alveolar bone?

被引:49
作者
Gonzalez-Garcia, Raul [1 ,2 ]
Monje, Florencio [1 ,2 ]
机构
[1] Univ Hosp Infanta Cristina, Dept Oral & Maxillofacial Head & Neck Surg, Badajoz, Spain
[2] Ctr Implantol & Cirugia Oral & Maxilofacial, Badajoz, Spain
关键词
bone architecture; bone density; bone micro-structure; dental implants; histomorphometry; maxillary bones; micro-computed tomography; optic microscopy; stereology; surface electronic microscopy; trabecular bone; MORPHOMETRIC-ANALYSIS; HISTOLOGIC SECTIONS; MU-CT; HISTOMORPHOMETRY; MICRORADIOGRAPHY; BIOPSIES;
D O I
10.1111/j.1600-0501.2012.02478.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives To analyze the reliability of micro-computed tomography (micro-CT) to assess bone density and the microstructure of the maxillary bones at the alveolar process in human clinics by direct comparison with conventional stereologic-based histomorphometry. Materials and methods Analysis of osseous microstructural variables including bone volumetric density (BV/TV) of 39 biopsies from the maxillary alveolar bone was performed by micro-CT. Conventional stereologic-based histomorphometry of 10 bone biopsies was performed by optic microscopy (OM) and low-vacuum surface electronic microscopy (SEM). Percentages of bone between micro-CT and conventional stereologic-based histomorphometry were compared. Results Significant positive correlations were observed between BV/TV and the percentage of bone (%Bone) analyzed by SEM (r=0.933, P<0.001), by toluidine blue staining OM (r=0.950, P<0.001) and by dark field OM (r=0.667, P=0.05). The high positive correlation coefficient between BV/TV and trabecular thickness illustrates that a value of BV/TV upper than 50% squares with a bone presenting most of their trabecules thicker than 0.2mm. The high negative correlation between BV/TV and trabecular separation shows that values of BV/TV upper than 50% squares with a bone presenting most of their trabecules separated less than 0.3mm each other. Conclusion BV/TV assessed by micro-CT correlates with the percentage of bone assessed by conventional stereologic-based histomorphometry. Micro-CT is a reliable technique to determine the bone density and the microstructure of the maxillary alveolar bone at the site of dental implant insertion.
引用
收藏
页码:730 / 737
页数:8
相关论文
共 18 条
[1]   Biomechanical aspects of initial intraosseous stability and implant design:: a quantitative micro-morphometric analysis [J].
Akca, Kivanc ;
Chang, Ting-Ling ;
Tekdemir, Ibrahim ;
Fanuscu, Mete I. .
CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (04) :465-472
[2]   Guidelines for Assessment of Bone Microstructure in Rodents Using Micro-Computed Tomography [J].
Bouxsein, Mary L. ;
Boyd, Stephen K. ;
Christiansen, Blaine A. ;
Guldberg, Robert E. ;
Jepsen, Karl J. ;
Mueller, Ralph .
JOURNAL OF BONE AND MINERAL RESEARCH, 2010, 25 (07) :1468-1486
[3]   Comparison insight bone measurements by histomorphometry and μCT [J].
Chappard, D ;
Retailleau-Gaborit, N ;
Legrand, E ;
Baslé, MF ;
Audran, M .
JOURNAL OF BONE AND MINERAL RESEARCH, 2005, 20 (07) :1177-1184
[4]  
Dapia-Robleda S., 2005, ACTA ORTOPEDICA GALL, V1, P34
[5]  
De Maeztu MA, 2007, INT J ORAL MAX IMPL, V22, P273
[6]   HIGH SPATIAL-RESOLUTION IMAGING OF BONE-MINERAL USING COMPUTED MICROTOMOGRAPHY - COMPARISON WITH MICRORADIOGRAPHY AND UNDECALCIFIED HISTOLOGIC SECTIONS [J].
ENGELKE, K ;
GRAEFF, W ;
MEISS, L ;
HAHN, M ;
DELLING, G .
INVESTIGATIVE RADIOLOGY, 1993, 28 (04) :341-349
[7]   Specimen size and porosity can introduce error into μCT-based tissue mineral density measurements [J].
Fajardo, Roberto J. ;
Cory, Esther ;
Patel, Nipun D. ;
Nazarian, Ara ;
Laib, Andres ;
Manoharan, Rajaram K. ;
Schmitz, James E. ;
DeSilva, Jeremy M. ;
MacLatchy, Laura M. ;
Snyder, Brian D. ;
Bouxsein, Mary L. .
BONE, 2009, 44 (01) :176-184
[8]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[9]   A comparison of micro-CT, microradiography and histomorphometry in bone research [J].
Gielkens, Pepijn F. M. ;
Schortinghuis, Jurjen ;
de Jong, Johan R. ;
Huysmans, Marie Charlotte D. N. J. M. ;
van Leeuwen, M. Barbara M. ;
Raghoebar, Gerry M. ;
Bos, Ruud R. M. ;
Stegenga, Boudewijn .
ARCHIVES OF ORAL BIOLOGY, 2008, 53 (06) :558-566
[10]   A new method for the model-independent assessment of thickness in three-dimensional images [J].
Hildebrand, T ;
Ruegsegger, P .
JOURNAL OF MICROSCOPY-OXFORD, 1997, 185 :67-75