GlideScope-assisted nerve integrity monitoring tube placement for intra-operative recurrent laryngeal nerve monitoring

被引:12
作者
Kanotra, S. P. [1 ]
Kuriloff, D. B. [1 ]
Lesser, J. [2 ]
Rest-Flarer, F. [2 ]
机构
[1] St Lukes Roosevelt Hosp, Dept Otolaryngol Head & Neck Surg, Ctr Thyroid & Parathyroid Surg, New York, NY USA
[2] St Lukes Roosevelt Hosp, Dept Anesthesiol, New York, NY USA
关键词
Monitoring; Intraoperative; Intubation; Endotracheal; Thyroidectomy; Recurrent Laryngeal Nerve; Laryngoscopy;
D O I
10.1017/S0022215112002460
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective: The proper positioning of the Nerve Integrity Monitoring (R) endotracheal tube during recurrent laryngeal nerve monitoring is of paramount importance. This article describes our experience with the GlideScope (R) and explains how it can facilitate the accurate placement of the Nerve Integrity Monitoring endotracheal tube. Methods: Endotracheal intubation with the Nerve Integrity Monitoring endotracheal tube was performed in 250 patients undergoing thyroidectomies using the GlideScope video laryngoscope. The correct positioning of the tube was determined according to impedance values of less than 5 kohm and an impedance imbalance of less than 1 kohm. Results: Successful intubation was achieved in all cases. The GlideScope aided the correct placement of the Nerve Integrity Monitoring endotracheal tube in the majority of the cases. Conclusion: The GlideScope provides an excellent means to ensure the correct positioning of the Nerve Integrity Monitoring tube. It allows both the surgeon and the anaesthesiologist to participate in the intubation process and confirm correct placement of the tube, whilst also allowing gentle intubation with improved visibility.
引用
收藏
页码:1271 / 1273
页数:3
相关论文
共 4 条
  • [1] Optimal depth of NIM EMG endotracheal tube for intraoperative neuromonitoring of the recurrent laryngeal nerve during thyroidectomy
    Lu, I-Chen
    Chu, Koung-Shing
    Tsai, Cheng-Jing
    Wu, Che-Wei
    Kuo, Wen-Rei
    Chen, Hsiu-Ya
    Lee, Ka-Wo
    Chiang, Feng-Yu
    [J]. WORLD JOURNAL OF SURGERY, 2008, 32 (09) : 1935 - 1939
  • [2] Electrophysiologic Recurrent Laryngeal Nerve Monitoring During Thyroid and Parathyroid Surgery: International Standards Guideline Statement
    Randolph, Gregory W.
    Dralle, Henning
    Abdullah, Hisham
    Barczynski, Marcin
    Bellantone, Rocco
    Brauckhoff, Michael
    Carnaille, Bruno
    Cherenko, Sergii
    Chiang, Fen-Yu
    Dionigi, Gianlorenzo
    Finck, Camille
    Hartl, Dana
    Kamani, Dipti
    Lorenz, Kerstin
    Miccolli, Paolo
    Mihai, Radu
    Miyauchi, Akira
    Orloff, Lisa
    Perrier, Nancy
    Poveda, Manuel Duran
    Romanchishen, Anatoly
    Serpell, Jonathan
    Sitges-Serra, Antonio
    Sloan, Tod
    Van Slycke, Sam
    Snyder, Samuel
    Takami, Hiroshi
    Volpi, Erivelto
    Woodson, Gayle
    [J]. LARYNGOSCOPE, 2011, 121 : S1 - S16
  • [3] The GlideScope® Video Laryngoscope:: randomized clinical trial in 200 patients
    Sun, DA
    Warriner, CB
    Parsons, DG
    Klein, R
    Umedaly, HS
    Moult, M
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2005, 94 (03) : 381 - 384
  • [4] Xue FS, 2007, MINERVA ANESTESIOL, V73, P451