Free-breathing whole-heart 3D cine magnetic resonance imaging with prospective respiratory motion compensation

被引:29
|
作者
Moghari, Mehdi H. [1 ,2 ]
Barthur, Ashita [1 ]
Amaral, Maria E. [1 ]
Geva, Tal [1 ,2 ]
Powell, Andrew J. [1 ,2 ]
机构
[1] Boston Childrens Hosp, Dept Cardiol, 300 Longwood Ave, Boston, MA 02115 USA
[2] Harvard Med Sch, Dept Pediat, Boston, MA USA
基金
美国国家卫生研究院;
关键词
free-breathing; whole-heart; 3D cine; ventricular function; respiratory motion correction; self-navigator; EXTRACELLULAR CONTRAST AGENT; K-T BLAST; VENTRICULAR VOLUMES; CORONARY MRA; CARDIAC CINE; PRECESSION; RECONSTRUCTION; VISUALIZATION; ANGIOGRAPHY; GRAPPA;
D O I
10.1002/mrm.27021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop and validate a new prospective respiratory motion compensation algorithm for free-breathing whole-heart 3D cine steady-state free precession (SSFP) imaging. MethodsIn a 3D cine SSFP sequence, 4 excitations per cardiac cycle are re-purposed to prospectively track heart position. Specifically, their 1D image is reconstructed and routed into the scanner's standard diaphragmatic navigator processing system. If all 4 signals are in end-expiration, cine image data from the entire cardiac cycle is accepted for image reconstruction. Prospective validation was carried out in patients (N=17) by comparing in each a conventional breath-hold 2D cine ventricular short-axis stack and a free-breathing whole-heart 3D cine data set. ResultsAll 3D cine SSFP acquisitions were successful and the mean scan time was 5.92.7min. Left and right ventricular end-diastolic, end-systolic, and stroke volumes by 3D cine SSFP were all larger than those from 2D cine SSFP. This bias was<6% except for right ventricular end-systolic volume that was 12%. The 3D cine images had a lower ventricular blood-to-myocardium contrast ratio, contrast-to-noise ratio, mass, and subjective quality score. ConclusionThe novel prospective respiratory motion compensation method for 3D cine SSFP imaging was robust and efficient and yielded slightly larger ventricular volumes and lower mass compared to breath-hold 2D cine imaging. Magn Reson Med 80:181-189, 2018. (c) 2017 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:181 / 189
页数:9
相关论文
共 50 条
  • [41] Fast, free-breathing and motion-minimized techniques for pediatric body magnetic resonance imaging
    Jaimes, Camilo
    Kirsch, John E.
    Gee, Michael S.
    PEDIATRIC RADIOLOGY, 2018, 48 (09) : 1197 - 1208
  • [42] Motion robust high resolution 3D free-breathing pulmonary MRI using dynamic 3D image self-navigator
    Jiang, Wenwen
    Ong, Frank
    Johnson, Kevin M.
    Nagle, Scott K.
    Hope, Thomas A.
    Lustig, Michael
    Larson, Peder E. Z.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (06) : 2954 - 2967
  • [43] Self-guided retrospective motion correction (SEGMO) for free-breathing whole-heart coronary MRA with 100% acquisition efficiency
    Jianing Pang
    Himanshu Bhat
    Behzad Sharif
    Zhaoyang Fan
    Edward B Gill
    James Min
    Troy Labounty
    Louise Thomson
    John D Friedman
    Daniel S Berman
    Debiao Li
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [44] Left ventricular volume measurements with free breathing respiratory self-gated 3-dimensional golden angle radial whole-heart cine imaging - Feasibility and reproducibility
    Holst, Karen
    Ugander, Martin
    Sigfridsson, Andreas
    MAGNETIC RESONANCE IMAGING, 2017, 43 : 48 - 55
  • [45] Free-Breathing 3D Cardiac MRI Using Iterative Image-Based Respiratory Motion Correction
    Moghari, Mehdi H.
    Roujol, Sebastien
    Chan, Raymond H.
    Hong, Susie N.
    Bello, Natalie
    Henningsson, Markus
    Ngo, Long H.
    Goddu, Beth
    Goepfert, Lois
    Kissinger, Kraig V.
    Manning, Warren J.
    Nezafat, Reza
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (04) : 1005 - 1015
  • [46] Free-breathing cardiovascular cine magnetic resonance imaging using compressed-sensing and retrospective motion correction: accurate assessment of biventricular volume at 3T
    Takakado, Masahiro
    Kido, Tomoyuki
    Ogawa, Ryo
    Takimoto, Yoshihiro
    Tokuda, Tsuyoshi
    Tanabe, Yuki
    Kawaguchi, Naoto
    Pang, Jianing
    Komori, Yoshiaki
    Kido, Teruhito
    JAPANESE JOURNAL OF RADIOLOGY, 2023, 41 (02) : 142 - 152
  • [47] Free-breathing cardiovascular cine magnetic resonance imaging using compressed-sensing and retrospective motion correction: accurate assessment of biventricular volume at 3T
    Masahiro Takakado
    Tomoyuki Kido
    Ryo Ogawa
    Yoshihiro Takimoto
    Tsuyoshi Tokuda
    Yuki Tanabe
    Naoto Kawaguchi
    Jianing Pang
    Yoshiaki Komori
    Teruhito Kido
    Japanese Journal of Radiology, 2023, 41 : 142 - 152
  • [48] Free-Breathing Single Navigator Gated Cine Cardiac Magnetic Resonance at 3 T: Feasibility Study in Patients
    Abd-Elmoniem, Khaled Z.
    Obele, Chika C.
    Sibley, Christopher T.
    Matta, Jatin R.
    Pettigrew, Roderic I.
    Gharib, Ahmed M.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (03) : 382 - 386
  • [49] A review of 3D first-pass, whole-heart, myocardial perfusion cardiovascular magnetic resonance
    Fair, Merlin J.
    Gatehouse, Peter D.
    DiBella, Edward V. R.
    Firmin, David N.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
  • [50] A review of 3D first-pass, whole-heart, myocardial perfusion cardiovascular magnetic resonance
    Merlin J. Fair
    Peter D. Gatehouse
    Edward V. R. DiBella
    David N. Firmin
    Journal of Cardiovascular Magnetic Resonance, 17