Subharmonic and Endoscopic Contrast Imaging of Pancreatic Masses: A Pilot Study

被引:5
作者
Forsberg, Flemming [1 ]
Stanczak, Maria [1 ]
Lyshchik, Andrej [1 ]
Loren, David [2 ]
O'Kane, Patrick [1 ]
Siddiqui, Ali [2 ]
Kowalski, Thomas E. [2 ]
Miller, Cynthia [2 ]
Fox, Traci [1 ,3 ]
Liu, Ji-Bin [1 ]
Eisenbrey, John R. [1 ]
机构
[1] Thomas Jefferson Univ, Dept Radiol, 137 S 10th St,7 Main,Suite 763H, Philadelphia, PA 19107 USA
[2] Thomas Jefferson Univ, Gastroenterol & Hepatol, Philadelphia, PA 19107 USA
[3] Thomas Jefferson Univ, Radiol Sci, Jefferson Coll Hlth Profess, Philadelphia, PA 19107 USA
基金
美国国家卫生研究院;
关键词
abdominal; contrast agents; endoscopic contrast ultrasound; pancreatic cancer; subharmonic imaging; PRESSURE ESTIMATION; BREAST-LESIONS; ULTRASOUND;
D O I
10.1002/jum.14310
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
ObjectivesTo use subharmonic imaging (SHI) to depict the vascularity of pancreatic masses compared to contrast-enhanced endoscopic ultrasound (EUS) and pathologic results. MethodsSixteen patients scheduled for biopsy of a pancreatic mass were enrolled in an Institutional Review Board-approved study. Pulse-inversion SHI (transmitting/receiving at 2.5/1.25 MHz) was performed on a LOGIQ 9 system (GE Healthcare, Milwaukee, WI) with a 4C transducer, whereas contrast harmonic EUS (transmitting/receiving at 4.7/9.4 MHz) was performed with a radial endoscope (GF-UTC180; Olympus Corporation, Tokyo, Japan) connected to a ProSound SSD -10 scanner (Hitachi Aloka, Tokyo, Japan). Two injections of the contrast agent Definity (Lantheus Medical Imaging, North Billerica, MA) were administrated (0.3-0.4 and 0.6-0.8mL for EUS and SHI, respectively). Contrast-to-tissue ratios (CTRs) in the mass and an adjacent vessel were calculated. Four physicians independently scored the images (benign to malignant) for diagnostic accuracy and inter-reader agreement. ResultsOne patient dropped out before imaging, leaving 11 adenocarcinomas, 1 gastrointestinal stromal tumor with pancreatic infiltration, and 3 benign masses. Marked subharmonic signals were obtained in all patients, with intratumoral blood flow clearly visualized with SHI. Significantly greater CTRs were obtained in the masses with SHI than with EUS (meanSD, 1.71 +/- 1.63 versus 0.63 +/- 0.89; P=.016). There were no differences in the CTR in the surrounding vessels or when grouped by pathologic results (P>.60). The accuracies for contrast EUS and SHI were low (<53%), albeit with a greater value for SHI (0.34) than for EUS (0.13). ConclusionsDiagnostic accuracy of contrast EUS and transabdominal SHI for assessment of pancreatic masses was quite low in this pilot study. However, SHI had improved tumoral CTRs relative to contrast EUS.
引用
收藏
页码:123 / 129
页数:7
相关论文
共 30 条
[1]   Nondestructive subharmonic imaging [J].
Chomas, J ;
Dayton, P ;
May, D ;
Ferrara, K .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (07) :883-892
[2]   Prognostic factors in resected pancreatic adenocarcinoma: Analysis of actual 5-year survivors [J].
Cleary, SP ;
Gryfe, R ;
Guindi, M ;
Greig, P ;
Smith, L ;
Mackenzie, R ;
Strasberg, S ;
Hanna, S ;
Taylor, B ;
Langer, B ;
Gallinger, S .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2004, 198 (05) :722-731
[3]   Static and Dynamic Cumulative Maximum Intensity Display Mode for Subharmonic Breast Imaging A Comparative Study With Mammographic and Conventional Ultrasound Techniques [J].
Dave, Jaydev K. ;
Forsberg, Flemming ;
Fernandes, Savitha ;
Piccoli, Catherine W. ;
Fox, Traci B. ;
Merton, Daniel A. ;
Leodore, Lauren M. ;
Hall, Anne L. .
JOURNAL OF ULTRASOUND IN MEDICINE, 2010, 29 (08) :1177-1185
[4]   Future applications of contrast echocardiography [J].
Davidson, Brian P. ;
Lindner, Jonathan R. .
HEART, 2012, 98 (03) :246-253
[5]   Contrast-enhanced endoscopic ultrasound with low mechanical index: A new technique [J].
Dietrich, CF ;
Ignee, A ;
Frey, H .
ZEITSCHRIFT FUR GASTROENTEROLOGIE, 2005, 43 (11) :1219-1223
[6]   Simultaneous grayscale and subharmonic ultrasound imaging on a modified commercial scanner [J].
Eisenbrey, J. R. ;
Dave, J. K. ;
Halldorsdottir, V. G. ;
Merton, D. A. ;
Machado, P. ;
Liu, J. B. ;
Miller, C. ;
Gonzalez, J. M. ;
Park, S. ;
Dianis, S. ;
Chalek, C. L. ;
Thomenius, K. E. ;
Brown, D. B. ;
Navarro, V. ;
Forsberg, F. .
ULTRASONICS, 2011, 51 (08) :890-897
[7]   Contrast-enhanced ultrasound for molecular imaging of angiogenesis [J].
Eisenbrey, J. R. ;
Forsberg, F. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 :S138-S146
[8]   Chronic Liver Disease: Noninvasive Subharmonic Aided Pressure Estimation of Hepatic Venous Pressure Gradient [J].
Eisenbrey, John R. ;
Dave, Jaydev K. ;
Halldorsdottir, Valgerdur G. ;
Merton, Daniel A. ;
Miller, Cynthia ;
Gonzalez, Jose M. ;
Machado, Priscilla ;
Park, Suhyun ;
Dianis, Scott ;
Chalek, Carl L. ;
Kim, Christopher E. ;
Baliff, Jeffrey P. ;
Thomenius, Kai E. ;
Brown, Daniel B. ;
Navarro, Victor ;
Forsberg, Flemming .
RADIOLOGY, 2013, 268 (02) :581-588
[9]   Three-Dimensional Subharmonic Ultrasound Imaging In Vitro and In Vivo [J].
Eisenbrey, John R. ;
Sridharan, Anush ;
Machado, Priscilla ;
Zhao, Hongjia ;
Halldorsdottir, Valgerdur G. ;
Dave, Jaydev K. ;
Liu, Ji-Bin ;
Park, Suhyun ;
Dianis, Scott ;
Wallace, Kirk ;
Thomenius, Kai E. ;
Forsberg, Flemming .
ACADEMIC RADIOLOGY, 2012, 19 (06) :732-739
[10]   CHARACTERIZING THE SUBHARMONIC RESPONSE OF PHOSPHOLIPID-COATED MICROBUBBLES FOR CAROTID IMAGING [J].
Faez, Telli ;
Emmer, Marcia ;
Docter, Margreet ;
Sijl, Jeroen ;
Versluis, Michel ;
de Jong, Nico .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (06) :958-970