Solid phase extraction and LC-MS/MS quantification of ibandronate in human plasma

被引:0
|
作者
Moustapha, Moustapha E. [1 ,2 ]
Abdel-Gawad, Sherif A. [3 ,4 ]
机构
[1] Prince Sattam Bin Abdulaziz Univ, Coll Sci & Humanities, Dept Chem, Ai Kharj 11942, Saudi Arabia
[2] Prince Sattam BinAbdulaziz Univ, Univ Cent Lab, Coll Sci & Humanities, Al Kharj 11942, Saudi Arabia
[3] Prince Sattam BinAbdulaziz Univ, Coll Pharm, Pharmaceut Chem Dept, Al Kharj, Saudi Arabia
[4] Cairo Univ, Fac Pharm, Analyt Chem Dept, Cairo, Egypt
关键词
Ibandronate; LC-MS/MS; Validation; Derivatization; Solid-phase extraction; ALENDRONATE;
D O I
10.4314/tjpr.v19i6.26
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Purpose: To develop and validate a simple, highly sensitive and accurate method for the quantification of ibandronate (IBN) in human plasma. Methods: Electrospray ionization liquid chromatography tandem mass spectrometry (LC-MS/MS) in positive ion mode was applied to obtain optimum signals. The parent ion was acquired under collision-activated dissociation conditions, and the abundant fragments used to design multiple reaction monitoring experiments for monitoring two ibandronate transitions (m/z 376 to m/z 114, and m/z 376 to m/z 250). The IBN was isolated from plasma with weak anion exchange solid phase extraction columns with 'on-cartridge' derivatization using tri-methylsilyl-diazomethane (TMSDZ) reagent to convert IBN to tetra-methyl derivative. Results: The studied drug was successfully extracted from plasma samples without any interference at a retention time of 3.2 min. The matrix effect averaged 110 %, indicating that endogenous materials had little effect on ionization. The relationship between plasma analyte concentration and IBN signal area was satisfactorily linear, with correlation coefficient (r2) ranging from 0.9817 to 0.9942 in the concentration range of 0.5 - 200 ng/ml. The lower and upper limits of quantification (LLOQ and ULOQ) for IBN were 0.5 and 200 ng/ml, respectively. Relative recovery of IBN from plasma after extraction and derivatization at 3 distinct concentrations was 83.93 to 85.06 %, relative to standard solutions. The ranges of intra- and inter-day accuracies of quantification of quality controls were 89.39 - 106.40 %, and 90.50 - 107.96 %, respectively. Processed plasma IBN extracts were stable in autosampler at 4 0C (91.12 to 103.49%). Long-term stability in plasma after 30 days at -24 0C ranged from 89.52 to 113.18 %. Conclusion: This validated LC-MS/MS method can be successfully applied for determination of IBN in pharmacokinetic studies. It is a sensitive and specific assay for plasma IBN in bioequivalence studies.
引用
收藏
页码:1295 / 1302
页数:8
相关论文
共 50 条
  • [41] Investigation of the metabolic stability of olmutinib by validated LC-MS/MS: quantification in human plasma
    Attwa, Mohamed W.
    Kadi, Adnan A.
    Darwish, Hany W.
    Abdelhameed, Ali S.
    RSC ADVANCES, 2018, 8 (70): : 40387 - 40394
  • [42] Quantification of the janus kinase 1 inhibitor upadacitinib in human plasma by LC-MS/MS
    Martens-Lobenhoffer, Jens
    Tomaras, Stylianos
    Feist, Eugen
    Bode-Boeger, Stefanie M.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2022, 1188
  • [43] Quantification of pantoprazole in human plasma using LC-MS/MS for pharmacokinetics and bioequivalence study
    Yun Li
    Mei-Juan Ding
    Jing Ma
    Shu Wang
    Xiao-Li Wu
    Hui-Juan Xu
    Zheng-Yu Lu
    Jian-Jun Zou
    Hong-Wei Fan
    Xue-Min Zhou
    European Journal of Drug Metabolism and Pharmacokinetics, 2011, 35 : 147 - 155
  • [44] Development, Validation, and Comparison of Two Mass Spectrometry Methods (LC-MS/HRMS and LC-MS/MS) for the Quantification of Rituximab in Human Plasma
    Millet, Aurelien
    Khoudour, Nihel
    Lebert, Dorothee
    Machon, Christelle
    Terrier, Benjamin
    Blanchet, Benoit
    Guitton, Jerome
    MOLECULES, 2021, 26 (05):
  • [45] Isocyanate derivatization coupled with phospholipid removal microelution-solid phase extraction for the simultaneous quantification of (S)-metoprolol and (S)-α-hydroxymetoprolol in human plasma with LC-MS/MS
    Meloche, Maxime
    Jutras, Martin
    St-Jean, Isabelle
    de Denus, Simon
    Leclair, Gregoire
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 204
  • [46] A rapid and specific approach for direct measurement of donepezil concentration in human plasma by LC-MS/MS employing solid-phase extraction
    Shah, Hiten J.
    Kundlik, Mohan L.
    Pandya, Ankit
    Prajapati, Shivkurnar
    Subbaiah, Gunta
    Patel, Chhagan N.
    Patel, Dasharath M.
    Suhagiya, Bhanu N.
    BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (02) : 141 - 151
  • [47] Measurement of bempedoic acid and its keto metabolite in human plasma and urine using solid phase extraction and electrospray LC-MS/MS
    Engel, Brian J.
    Preusch, Karen
    Brown, Cameron
    Cramer, Clay T.
    Shoup, Ronald
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1154
  • [48] Sensitive determination of erdosteine in human plasma by use of automated 96-well solid-phase extraction and LC-MS/MS
    Kim, HY
    Chang, KY
    Lee, HJ
    Han, SB
    Lee, KR
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (03) : 661 - 669
  • [49] An evaporation-free solid-phase extraction method for rapid and accurate analysis of sumatriptan in human plasma by LC-MS/MS
    Tan, Aimin
    Hang, Peter
    Couture, Jean
    Hussain, Saleh
    Vallee, Francois
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 856 (1-2): : 9 - 14
  • [50] Quantitation of Cabozantinib in Human Plasma by LC-MS/MS
    Jones, Reyna
    Holleran, Julianne
    Parise, Robert A.
    Rudek, Michelle A.
    Chan, Jennifer
    Wen, Yujia
    Gobburu, Joga
    Lewis, Lionel D.
    Beumer, Jan H.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2022, 60 (03) : 274 - 279