Physical, morphological and dosimetric characterization of the Teflon agglutinator to thermoluminescent dosimetry

被引:17
作者
d'Amorim, R. A. P. O. [1 ]
Teixeira, M. I. [2 ]
Caldas, L. V. E. [2 ]
Souza, S. O. [1 ]
机构
[1] Univ Fed Sergipe, Dept Fis CCET, BR-49100000 Sao Cristovao, SE, Brazil
[2] Inst Pesquisas Energet & Nucl IPEN CNEN SP, BR-05508000 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Teflon; Dosimetry; Thermoluminescence; Dosimetric characterization; TSEE RESPONSE; PELLETS; CRYSTALLINE; COMPOSITES; BEAMS;
D O I
10.1016/j.jlumin.2012.11.045
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In preparing of thermoluminescent dosimeters (TLD) it is common to use as agglutinator the polytetrafluoroethylene (PTFE), called Teflon (R). In this paper the physical, morphological and dosimetric characteristics of Teflon (R) were evaluated aiming its application in thermoluminescent dosimetry. The differential thermal analysis (DTA) and thermogravimetry (TG) results showed that the Teflon glass transition and melting points are of about 48 degrees C and 340 degrees C, respectively. By means of the X-ray diffraction technique, the crystallinity index K-c was estimated as 94%. Micrographs of Scanning Electron Microscopy (SEM) showed a cohesive surface in spodumene-Teflon pellets, as required for thermoluminescent dosimeters (TLD), leading to the conclusion that Teflon acts as binder, providing greater mechanical resistance to the TL pellets. However, Teflon may influence high doses dosimetry when it is applied as an agglutinator. Preliminary results of Teflon pellets dosimetric properties, with their dose-response curve between 50 Gy and 60 kGy, TL response reproducibility and minimum detectable dose, indicate the possibility of use of pure Teflon TLD in high-dose dosimetry. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:186 / 190
页数:5
相关论文
共 19 条
[1]   PROPERTIES OF LITHIUM FLUORIDE-TEFLON THERMOLUMINESCENCE DOSIMETERS AND THEIR USE IN RADIOLOGY [J].
BJARNGARD, BE .
RADIOLOGY, 1966, 86 (01) :144-+
[2]  
Canto R.B., 2007, THESIS SAO CARLOS, P188
[3]   Influence of Teflon® agglutinator on TLD spodumene pellets [J].
d'Amorim, R. A. P. O. ;
Teixeira, M. I. ;
Souza, S. O. ;
Sasaki, J. M. ;
Caldas, L. V. E. .
JOURNAL OF LUMINESCENCE, 2012, 132 (02) :266-269
[4]   Effect of carbon nanotubes on the photo-oxidative durability of syndiotactic polypropylene [J].
Guadagno, Liberata ;
Naddeo, Carlo ;
Raimondo, Marialuigia ;
Gorrasi, Giuliana ;
Vittoria, Vittoria .
POLYMER DEGRADATION AND STABILITY, 2010, 95 (09) :1614-1626
[5]   CHEMICAL DOSIMETRY OF MIXED RADIATIONS IN FNS TARGET ROOM [J].
IKEZOE, Y ;
ONUKI, K ;
NAKAJIMA, H ;
SATO, S ;
NAKAMURA, T .
JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1986, 23 (02) :179-181
[6]  
Jahier D., 1992, PUBLI CETIM, P102
[7]   Studies on automatic hot gas reader used in the countrywide personnel monitoring programme [J].
Kumar, M ;
Raja, EA ;
Prasad, LC ;
Popli, KL ;
Kher, RK ;
Bhatt, BC .
RADIATION PROTECTION DOSIMETRY, 2005, 113 (04) :366-373
[8]   Pulsed-laser deposition of crystalline Teflon (PTFE) films [J].
Li, ST ;
Arenholz, E ;
Heitz, J ;
Bauerle, D .
APPLIED SURFACE SCIENCE, 1998, 125 (01) :17-22
[9]  
Marinho J.R.D., 2005, MACROMOLECULES POLYM, P506
[10]   TSEE response of silicates of the jade family in gamma radiation beams [J].
Melo, Adeilson P. ;
Teixeira, Maria Ines ;
Caldas, Linda V. E. .