New non-invasive approach to detect cardiac contractility using the first sound of phonocardiogram

被引:3
作者
Yamashita, Koichi [1 ]
机构
[1] Kochi Red Cross Hosp, Div Crit Care Ctr, 4-63-11,Hadaminamimachi 1 Chome, Kochi, Kochi 7808562, Japan
来源
ACUTE MEDICINE & SURGERY | 2020年 / 7卷 / 01期
关键词
Performance; phonocardiogram; pre-ejection period; left ventricular contraction; SYSTOLIC-TIME INTERVALS; ACOUSTIC CARDIOGRAPHY; PREEJECTION PERIOD; HEART-FAILURE; PRESSURE; INDEXES; OUTPUT;
D O I
10.1002/ams2.483
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: During surgery, a non-invasive and easy-to-use method is required for evaluating left ventricular status. The systolic time interval, including pre-ejection period (PEP), of left ventricle has been known to be correlated with cardiac contractility. In this study, we focused on the non-invasive time interval from the Q wave of an electrocardiogram to the third component in the first heart sound (QS1-3rd) and evaluated the correlation between PEP and peak differentiated left ventricular pressure (LV dp/dt). Methods: Six adult anesthetized pigs were intubated. Mechanical ventilation was started. An electrocardiogram, carotid artery blood pressure, left ventricular pressure, and phonocardiogram on the fourth left intercostal space were monitored using a polygraph system. Cardiac output was measured by the thermodilution method. Data were simultaneously measured at baseline and after the infusion of noradrenaline, nitroprusside, esmolol sulfate, and dobutamine, respectively. Data were analyzed by Spearman's rank correlation coefficient using four-quadrant plot analysis. Results: A total of 270 points were simultaneously measured. The QS1-3rd showed a significant correlation with PEP (QS(1)-3rd = 7.62 + 0.92 PEP; q = 0.91, P < 0.0001). Concordance rate was 92% between PEP and QS(1)-3rd (excluded zones were set within +/- 5 ms). Both PEP and QS1-3rd showed a good correlation with LV dp/dt (LV dp/dt = 3861.3-24.4 PEP; q = 0.85, P < 0.0001, LV dp/dt = 3763.6-23.5 QS(1)-3rd; q = 0.82, P < 0.0001). Conclusion: This non-invasive and easy-to-use hemodynamic parameter (QS1-3rd) could be helpful for continuous monitoring of left cardiac contraction performance.
引用
收藏
页数:7
相关论文
共 16 条
  • [1] A Critical Review of the Ability of Continuous Cardiac Output Monitors to Measure Trends in Cardiac Output
    Critchley, Lester A.
    Lee, Anna
    Ho, Anthony M. -H.
    [J]. ANESTHESIA AND ANALGESIA, 2010, 111 (05) : 1180 - 1192
  • [2] EFFECTS OF ADRENERGIC RECEPTOR ACTIVATION AND BLOCKADE ON SYSTOLIC PREEJECTION PERIOD HEART RATE AND ARTERIAL PRESSURE IN MAN
    HARRIS, WS
    SCHOENFELD, CD
    WEISSLER, AM
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 1967, 46 (11) : 1704 - +
  • [3] HODGES M, 1972, CIRCULATION, V45, P933, DOI 10.1161/01.CIR.45.5.933
  • [4] TEMPORAL RELATION OF FIRST HEART SOUND TO CLOSURE OF MITRAL-VALVE
    LANIADO, S
    YELLIN, EL
    MILLER, H
    FRATER, RWM
    [J]. CIRCULATION, 1973, 47 (05) : 1006 - 1014
  • [5] LUISADA AA, 1987, JPN HEART J, V28, P143
  • [6] NONINVASIVE INDEX OF CARDIAC CONTRACTILITY DURING STRESS-TESTING - A COLLABORATIVE STUDY
    LUISADA, AA
    SINGHAL, A
    PORTALUPPI, F
    STROZZI, C
    [J]. CLINICAL CARDIOLOGY, 1985, 8 (07) : 375 - 384
  • [7] DIRECT CORRELATION OF EXTERNAL SYSTOLIC TIME INTERVALS WITH INTERNAL INDICES OF LEFT VENTRICULAR FUNCTION IN MAN
    MARTIN, CE
    SHAVER, JA
    THOMPSON, ME
    REDDY, PS
    LEONARD, JJ
    [J]. CIRCULATION, 1971, 44 (03) : 419 - &
  • [8] A NEW NONINVASIVE METHOD FOR THE ESTIMATION OF PEAK DP/DT
    RHODES, J
    UDELSON, JE
    MARX, GR
    SCHMID, CH
    KONSTAM, MA
    HIJAZI, ZM
    BOVA, SA
    FULTON, DR
    [J]. CIRCULATION, 1993, 88 (06) : 2693 - 2699
  • [9] Tracking Changes in Cardiac Output: Statistical Considerations on the 4-Quadrant Plot and the Polar Plot Methodology
    Saugel, Bernd
    Grothe, Oliver
    Wagner, Julia Y.
    [J]. ANESTHESIA AND ANALGESIA, 2015, 121 (02) : 514 - 524
  • [10] HEMODYNAMIC CORRELATES OF VARIOUS COMPONENTS OF FIRST HEART SOUND
    SHAH, PM
    MORI, M
    MACCANON, DM
    LUISADA, AA
    [J]. CIRCULATION RESEARCH, 1963, 12 (04) : 386 - &