Accuracy of CT biopsy: Laser guidance versus conventional freehand techniques

被引:22
作者
Pereles, FS
Baker, M
Baldwin, R
Krupinski, E
Unger, EC
机构
[1] Northwestern Univ, NW Mem Hosp, Dept Radiol, Chicago, IL 60611 USA
[2] Univ Arizona, Hlth Sci Ctr, Dept Radiol, Tucson, AZ USA
关键词
biopsies; technology; computed tomography (CT); guidance; lasers;
D O I
10.1016/S1076-6332(98)80260-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The purpose of this study was to determine whether laser-guided computed tomographic (CT) biopsy is more accurate than CT-guided biopsy with conventional freehand techniques. Materials and Methods. Two independent operators performed an equal number of freehand and laser-guided needle passes at varying single and double angles (0degrees, 30degrees, 60degrees, 25degrees/30degrees, and 25degrees/60degrees) on targets within six pork and beef phantoms. A total of 180 biopsy passes were performed, and error distances of needle tip to target were tabulated. Data were analyzed by means of repeated measures analysis of variance (ANOVA) to compare the accuracy of laser guidance with freehand passes ANOVA and correlation analysis were also used to confirm the relative equivalency of phantom targets and biopsy parameters. Results. Overall, laser-guided passes were statistically significantly more accurate than freehand passes. Mean error with laser guidance was 5.01 mm (standard error [SE] = 0.41 mm), whereas mean error with freehand techniques was 10.58 mm (SE = 0.82 mm) (F = 52.0, df = 1, 17, P = .0001). Ninety-three percent of laser-guided passes and 56% of freehand passes were within 1 cm of the intended target. Error increased for both laser-guided and freehand techniques with larger angles or double-angle biopsies, but the increases were greater with freehand technique. No statistically significant differences existed between the targets themselves or biopsy parameters for the two operators. Conclusion. Laser-guided CT biopsies were more accurate than freehand CT biopsies. Practical advantages of laser guidance over freehand CT biopsy methods may include decreased procedure times and reduced patient morbidity.
引用
收藏
页码:766 / 770
页数:5
相关论文
共 12 条
[1]   DEFLECTION OF SPINAL NEEDLES BY THE BEVEL [J].
DRUMMOND, GB ;
SCOTT, DHT .
ANAESTHESIA, 1980, 35 (09) :854-857
[2]   A LIGHT-GUIDANCE SYSTEM TO BE USED FOR CT-GUIDED BIOPSY [J].
FREDERICK, PR ;
BROWN, TH ;
MILLER, MH ;
BAHR, AL ;
TAYLOR, KH .
RADIOLOGY, 1985, 154 (02) :535-536
[3]  
MAGNUSSON A, 1991, ACTA RADIOL, V32, P83
[4]   LASER GUIDANCE-SYSTEM FOR CT-GUIDED PROCEDURES [J].
MIAUX, Y ;
GUERMAZI, A ;
GOSSOT, D ;
BOURRIER, P ;
ANGOULVANT, D ;
KHAIROUNE, A ;
TURKI, C ;
BOUCHE, E .
RADIOLOGY, 1995, 194 (01) :282-284
[5]   LASER PROJECTION SYSTEM FOR RADIOTHERAPY AND CT-GUIDED BIOPSY [J].
NAGATA, Y ;
NISHIDAI, T ;
ABE, M ;
HIRAOKA, M ;
TAKAHASHI, M ;
FUJIWARA, K ;
OKAJIMA, K .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (06) :1046-1048
[6]   CT BODY STEREOTAXIS - AN AID FOR CT-GUIDED BIOPSIES [J].
ONIK, G ;
COSTELLO, P ;
COSMAN, E ;
WELLS, T ;
GOLDBERG, H ;
MOSS, A ;
KANE, R ;
CLOUSE, ME ;
HODDICK, W ;
MOORE, S ;
DEMAS, B .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 146 (01) :163-168
[7]   CT-GUIDED ASPIRATIONS FOR THE BODY - COMPARISON OF HAND GUIDANCE WITH STEREOTAXIS [J].
ONIK, G ;
COSMAN, ER ;
WELLS, TH ;
GOLDBERG, HI ;
MOSS, AA ;
COSTELLO, P ;
KANE, RA ;
HODDICK, WI ;
DEMAS, B .
RADIOLOGY, 1988, 166 (02) :389-394
[8]   NEW DEVICE FOR CT-TARGETED PERCUTANEOUS PUNCTURES [J].
OZDOBA, C ;
VOIGT, K ;
NUSSLIN, F .
RADIOLOGY, 1991, 180 (02) :576-578
[9]   COMPREHENSIVE APPROACH TO CT-GUIDED PROCEDURES WITH A HAND-HELD GUIDANCE DEVICE [J].
PALESTRANT, AM .
RADIOLOGY, 1990, 174 (01) :270-272
[10]   IMAGE-DIRECTED PERCUTANEOUS BIOPSIES WITH A BIOPSY GUN [J].
PARKER, SH ;
HOPPER, KD ;
YAKES, WF ;
GIBSON, MD ;
OWNBEY, JL ;
CARTER, TE .
RADIOLOGY, 1989, 171 (03) :663-669