Evaluation of bedside sonographic measurement of optic nerve sheath diameter for assessment of raised intracranial pressure in adult head trauma patients

被引:7
|
作者
Mathews, Alvin [1 ]
Cattamanchi, Srihari [1 ]
Panneerselvam, Tamilanbu [1 ]
Trichur, Ramakrishnan, V [1 ]
机构
[1] Sri Ramachandra Med Coll & Res Inst, Dept Emergency Med, 1 Ramachandra Nagar, Chennai 600116, Tamil Nadu, India
关键词
Bedside assessment; emergency department; head trauma; intracranial pressure; optic nerve sheath diameter; sonographic measurement; trauma; ultrasonography; ULTRASONOGRAPHY; ULTRASOUND; INJURY;
D O I
10.4103/JETS.JETS_94_19
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Aim: The aim was to evaluate the use of bedside sonographic measurement of the optic nerve sheath diameter (ONSD) in the assessment of elevated intracranial pressure in patients with head injury coming to the emergency department (ED). Methods: A prospective study of ED patients presenting with a history of acute head injury, an ocular ultrasound was performed for ONSD measurement, followed by a computed tomography (CT) of the brain. Three measurements were taken for each eye, then, the mean binocular ONSD measurement for each patient was obtained to ensure accuracy. A mean bipolar ONSD >5 mm was considered abnormal. Results: A total of 175 patients were considered for the study. Of 175 patients, only 56 (32%) had intracranial pathology detected on CT brain with mean ONSD of 5.7 mm (standard deviation [SD]: 0.59). The mean ONSD for 119 (68%) patients, who had normal CT brain, was 4.5 mm (SD: 0.42). The mean ONSD measured for the right eye was 4.86 mm with SD 0.88, and the mean ONSD for the left eye was 4.90 mm with SD 0.85. When comparing ONSD measurement with CT findings of raised intracranial pressure, the ONSD sensitivity was 87.5% (95% confidence interval [CI]: 85%-96%) and specificity was 94.1% (95% CI: 85%-96%), with a positive predictive value of 87.5% and a negative predictive value of 94.1%. The area under the receiver operator characteristic curve obtained was 0.90 (95% CI: 0.85-0.96). Conclusion: The study has shown a bedside measurement of ONSD through sonography as an efficient tool to assess elevations in intracranial pressure in head injury patients.
引用
收藏
页码:190 / 195
页数:6
相关论文
共 50 条
  • [41] Sonographic optic nerve sheath diameter as a surrogate measure for intracranial pressure in anesthetized patients in the Trendelenburg position
    Chin, Ji-Hyun
    Seo, Hyungseok
    Lee, Eun-Ho
    Lee, Joohyun
    Hong, Jun Hyuk
    Hwang, Jai-Hyun
    Kim, Young-Kug
    BMC ANESTHESIOLOGY, 2015, 15
  • [42] Sonographic Optic Nerve Sheath Diameter as a Screening Tool for Detection of Elevated Intracranial Pressure
    Amini, Afshin
    Eghtesadi, Razieh
    Feizi, Ali Mohammad
    Mansouri, Behnam
    Kariman, Hamid
    Dolatabadi, Ali Arhami
    Hatamabadi, Hamidreza
    Kabir, Ali
    EMERGENCY, 2013, 1 (01): : 15 - 19
  • [43] Sonographic optic nerve sheath diameter as a surrogate measure for intracranial pressure in anesthetized patients in the Trendelenburg position
    Ji-Hyun Chin
    Hyungseok Seo
    Eun-Ho Lee
    Joohyun Lee
    Jun Hyuk Hong
    Jai-Hyun Hwang
    Young-Kug Kim
    BMC Anesthesiology, 15
  • [44] Measurement Of Optic Nerve Sheath Diameter By Trans-Orbital Ultrasound To Detect Raised Intracranial Pressure In Children
    Bansal, A. B.
    Tiwari, L. T.
    Kumar, P. K.
    ANNALS OF NEUROLOGY, 2023, 94 : S88 - S89
  • [45] Optic nerve sheath diameter measurement for predicting raised intracranial pressure in pediatric patients: A systematic review and meta-analysis
    Lee, Sun Hwa
    Yun, Seong Jong
    Kim, Dong Hyeon
    HONG KONG JOURNAL OF EMERGENCY MEDICINE, 2022, 29 (03) : 177 - 186
  • [46] Prospective Analysis of Single Operator Sonographic Optic Nerve Sheath Diameter Measurement for Diagnosis of Elevated Intracranial Pressure
    Frumin, Erica
    Schlang, Joelle
    Wiechmann, Warren
    Hata, Stacy
    Rosen, Sasha
    Anderson, Craig
    Pare, Laura
    Rosen, Mark
    Fox, John Christian
    WESTERN JOURNAL OF EMERGENCY MEDICINE, 2014, 15 (02) : 217 - 220
  • [47] Assessment of intracranial pressure with ultrasonographic measurement of optic nerve sheath diameter on patients undergoing suspension direct laryngoscopy
    Karali, Elif
    Demirhan, Abdullah
    Gunes, Akif
    Yildiz, Isa
    Ural, Ahmet
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2023, 280 (04) : 1835 - 1840
  • [48] Assessment of intracranial pressure with ultrasonographic measurement of optic nerve sheath diameter on patients undergoing suspension direct laryngoscopy
    Elif Karali
    Abdullah Demirhan
    Akif Günes
    Isa Yildiz
    Ahmet Ural
    European Archives of Oto-Rhino-Laryngology, 2023, 280 : 1835 - 1840
  • [49] Optic Nerve Sheath Diameter Used as Ultrasonographic Assessment of the Incidence of Raised Intracranial Pressure in Preeclampsia A Pilot Study
    Dubost, Clement
    Le Gouez, Agnes
    Jouffroy, Viridiana
    Roger-Christoph, Sandrine
    Benhamou, Dan
    Mercier, Frederic J.
    Geeraerts, Thomas
    ANESTHESIOLOGY, 2012, 116 (05) : 1066 - 1071
  • [50] Quality And Feasibility of Sonographic Measurement of the Optic Nerve Sheath Diameter to Estimate the Risk of Raised Intracranial Pressure After Traumatic Brain Injury in Prehospital Setting
    Houze-Cerfon, Charles-Henri
    Bounes, Vincent
    Guemon, Johanna
    Le Gourrierec, Thibault
    Geeraerts, Thomas
    PREHOSPITAL EMERGENCY CARE, 2019, 23 (02) : 277 - 283