Evaluation of bedside sonographic measurement of optic nerve sheath diameter for assessment of raised intracranial pressure in adult head trauma patients

被引:7
|
作者
Mathews, Alvin [1 ]
Cattamanchi, Srihari [1 ]
Panneerselvam, Tamilanbu [1 ]
Trichur, Ramakrishnan, V [1 ]
机构
[1] Sri Ramachandra Med Coll & Res Inst, Dept Emergency Med, 1 Ramachandra Nagar, Chennai 600116, Tamil Nadu, India
关键词
Bedside assessment; emergency department; head trauma; intracranial pressure; optic nerve sheath diameter; sonographic measurement; trauma; ultrasonography; ULTRASONOGRAPHY; ULTRASOUND; INJURY;
D O I
10.4103/JETS.JETS_94_19
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Aim: The aim was to evaluate the use of bedside sonographic measurement of the optic nerve sheath diameter (ONSD) in the assessment of elevated intracranial pressure in patients with head injury coming to the emergency department (ED). Methods: A prospective study of ED patients presenting with a history of acute head injury, an ocular ultrasound was performed for ONSD measurement, followed by a computed tomography (CT) of the brain. Three measurements were taken for each eye, then, the mean binocular ONSD measurement for each patient was obtained to ensure accuracy. A mean bipolar ONSD >5 mm was considered abnormal. Results: A total of 175 patients were considered for the study. Of 175 patients, only 56 (32%) had intracranial pathology detected on CT brain with mean ONSD of 5.7 mm (standard deviation [SD]: 0.59). The mean ONSD for 119 (68%) patients, who had normal CT brain, was 4.5 mm (SD: 0.42). The mean ONSD measured for the right eye was 4.86 mm with SD 0.88, and the mean ONSD for the left eye was 4.90 mm with SD 0.85. When comparing ONSD measurement with CT findings of raised intracranial pressure, the ONSD sensitivity was 87.5% (95% confidence interval [CI]: 85%-96%) and specificity was 94.1% (95% CI: 85%-96%), with a positive predictive value of 87.5% and a negative predictive value of 94.1%. The area under the receiver operator characteristic curve obtained was 0.90 (95% CI: 0.85-0.96). Conclusion: The study has shown a bedside measurement of ONSD through sonography as an efficient tool to assess elevations in intracranial pressure in head injury patients.
引用
收藏
页码:190 / 195
页数:6
相关论文
共 50 条
  • [11] Ultrasound measurement of the optic nerve sheath diameter for monitoring patients with raised intracranial pressure - a case report
    Bender, M.
    Lakicevic, S.
    Radancevic, D.
    Malojcic, B.
    EUROPEAN JOURNAL OF NEUROLOGY, 2018, 25 : 58 - 59
  • [12] Accuracy of bedside sonographic measurement of optic nerve sheath diameter for intracranial hypertension diagnosis in the emergency department
    Busti, Chiara
    Marcosignori, Matteo
    Marchetti, Francesco
    Batori, Giuseppe
    Giovenali, Laura
    Corea, Francesco
    Calabro, Giuseppe
    Monti, Manuel
    Germini, Federico
    EMERGENCY CARE JOURNAL, 2023, 19 (02)
  • [13] Accuracy of bedside sonographic measurement of optic nerve sheath diameter for intracranial hypertension diagnosis in the emergency department
    Busti, Chiara
    Germini, Federico
    Calabro, Giuseppe
    Corea, Francesco
    Batori, Giuseppe
    Marchetti, Francesco
    Marcosignori, Matteo
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2021, 429
  • [14] ULTRASONOGRAPHY OF OPTIC NERVE SHEATH DIAMETER (ONSD) FOR RAISED INTRACRANIAL PRESSURE
    Siddiqui, Naveed Ur Rehman
    CRITICAL CARE MEDICINE, 2018, 46 (01) : 397 - 397
  • [15] Use of the sonographic diameter of optic nerve sheath to estimate intracranial pressure
    Amini, Afshin
    Kariman, Hamid
    Dolatabadi, Ali Arhami
    Hatamabadi, Hamid Reza
    Derakhshanfar, Hojjat
    Mansouri, Behnam
    Safari, Saeed
    Eqtesadi, Razie
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2013, 31 (01): : 236 - 239
  • [16] Transorbital Ultrasonographic Measurement of Optic Nerve Sheath Diameter for Intracranial Midline Shift in Patients with Head Trauma
    Kazdal, Hizir
    Kanat, Ayhan
    Findik, Huseyin
    Sen, Ahmet
    Ozdemir, Bulent
    Batcik, Osman Ersegun
    Yavasi, Ozcan
    Inecikli, Mehmet Fatih
    WORLD NEUROSURGERY, 2016, 85 : 292 - 297
  • [17] Optic Nerve Sheath Diameter Assessment in Patients with Intracranial Pressure Monitoring
    Kavi, Tapan
    Gupta, Anuj
    Hunter, Krystal
    Schreiber, Craig
    Shaikh, Hamza
    Turtz, Alan R.
    CUREUS, 2018, 10 (11):
  • [18] Assessment of intracranial pressure with ultrasonographic retrobulbar optic nerve sheath diameter measurement
    Liu, Dachuan
    Li, Zhen
    Zhang, Xuxiang
    Zhao, Liping
    Jia, Jianping
    Sun, Fei
    Wang, Yaxing
    Ma, Daqing
    Wei, Wenbin
    BMC NEUROLOGY, 2017, 17
  • [19] Assessment of intracranial pressure with ultrasonographic retrobulbar optic nerve sheath diameter measurement
    Dachuan Liu
    Zhen Li
    Xuxiang Zhang
    Liping Zhao
    Jianping Jia
    Fei Sun
    Yaxing Wang
    Daqing Ma
    Wenbin Wei
    BMC Neurology, 17
  • [20] Detection of raised intracranial pressure by ultrasound measurement of optic nerve sheath diameter in African children
    Beare, Nicholas A. V.
    Kampondeni, Sam
    Glover, Simon J.
    Molyneux, Elizabeth
    Taylor, Terrie E.
    Harding, Simon P.
    Molyneux, Malcolm E.
    TROPICAL MEDICINE & INTERNATIONAL HEALTH, 2008, 13 (11) : 1400 - 1404