Real-time 3D image guided patient positioning in radiation therapy

被引:0
|
作者
Liu, Dezhi [1 ]
Yin, Gongjie [2 ]
Li, Shidong [1 ]
机构
[1] Henry Ford Hlth Syst, Dept Radiat Oncol, Detroit, MI 48202 USA
[2] Genex Technol Inc, Kensington, MD USA
来源
THREE-DIMENSIONAL IMAGE CAPTURE AND APPLICATIONS VII | 2006年 / 6056卷
基金
美国国家卫生研究院;
关键词
3D imaging; image-guided radiotherapy; image fusion; patient repositioning;
D O I
10.1117/12.651361
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
Patient positioning in modem radiotherapy is becoming far more important because a small positioning error may result in missing target and irradiating normal tissues in treatment of small lesions. Clinical outcome of radiotherapy can potentially be improved by increasing the precision of tumor localization and dose delivery during the treatment. In this paper an accurate and precise patient positioning system has been achieved through alignment of real-time three dimensional 3D surface images with a reference surface image. The real-time 3D surface is captured using a state-of-art 3D stereovision system, and then is matched with the pre-defined reference image generated from treatment planning data. Positioning parameters are calculated by automatically aligning the real-time surface and the reference surface via a modified iterative closest point (ICP) algorithm. Results from phantom experiments and clinical applications demonstrated the excellent efficacy of < 2 minutes and the desired accuracy and precision of < 1 mm in isocenter shifts and of < 1 degree in rotations.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Real-Time 3D Image-Guided HIFU Therapy
    Ziadloo, Ali
    Vaezy, Shahram
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 4459 - 4462
  • [2] Towards real-time 2D/3D registration for organ motion monitoring in Image-Guided Radiation Therapy
    Gendrin, C.
    Spoerk, J.
    Bloch, C.
    Pawiro, S. A.
    Weber, C.
    Figl, M.
    Markelj, P.
    Pernus, F.
    Georg, D.
    Bergmann, H.
    Birkfellner, W.
    MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625
  • [3] Real-time Image-guided Radiation Therapy: A Survey
    Zhou, Shoujun
    Xiao, Shiqun
    Yang, Jun
    Wang, Wenhui
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2893 - +
  • [4] Real-time image-guided radiation therapy: A survey
    SHENZHEN Hyper Tech. Ltd., Shenzhen, 518057, China
    不详
    不详
    Int. Conf. Bioinformatics Biomed. Eng., iCBBE, 1600,
  • [5] Surface imaging for real-time patient positioning in external radiation therapy
    Nazir, Souha
    Bert, Julien
    Fayad, Hadi
    Visvikis, Dimitris
    MEDICAL PHYSICS, 2021, 48 (12) : 8037 - 8044
  • [6] Real-time 3D MR guided radiation therapy through orthogonal MR imaging and manifold learning
    Ginn, John
    Wang, Chunhao
    Yang, Deshan
    MEDICAL PHYSICS, 2025, 52 (03) : 1390 - 1398
  • [7] A real-time freehand 3D ultrasound system for image-guided surgery
    Welch, JN
    Johnson, JA
    Bax, MR
    Badr, R
    Shahidi, R
    2000 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2000, : 1601 - 1604
  • [8] Real-Time Tumor Motion Tracking in 3D Using Planning 4D CT Images during Image-Guided Radiation Therapy
    Choi, Jang-Hwan
    Lee, Sooyeul
    ALGORITHMS, 2018, 11 (10):
  • [9] Implementation of real-time 2D/3D image registration in radiation oncology
    Gendrin, C.
    Weber, C.
    Figl, M.
    Georg, D.
    Bergmann, H.
    Birkfellner, W.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 6, 2009, 25 : 51 - +
  • [10] Real-Time 3D Echo in Patient Selection for Cardiac Resynchronization Therapy
    Kapetanakis, Stamatis
    Bhan, Amit
    Murgatroyd, Francis
    Kearney, Mark T.
    Gall, Nicholas
    Zhang, Qing
    Yu, Cheuk-Man
    Monaghan, Mark J.
    JACC-CARDIOVASCULAR IMAGING, 2011, 4 (01) : 16 - 26