Clinical Outcome, Survival and Polyethylene Wear of an Uncemented Total Hip Arthroplasty A 10-to 12-Year Follow-Up Study of 81 Hips

被引:10
作者
Rienstra, Wietske [1 ]
van der Veen, Hugo C. [2 ]
van den Akker-Scheek, Inge [3 ]
van Raay, Jos J. A. M. [2 ]
机构
[1] Med Ctr Leeuwarden, Dept Orthopaed Surg, NL-8901 BR Leeuwarden, Netherlands
[2] Martini Hosp Groningen, Dept Orthopaed Surg, Groningen, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Orthopaed Surg, NL-9713 AV Groningen, Netherlands
关键词
uncemented total hip arthroplasty; survival; polyethylene wear; osteolysis; clinical outcome; influencing factors on wear; FEMORAL-HEAD SIZE; YOUNG-PATIENTS; PRESS-FIT; COMPONENTS; REPLACEMENT; CEMENTLESS; QUESTIONNAIRE; TRANSLATION; VALIDATION; RATES;
D O I
10.1016/j.arth.2012.10.004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A complete 10- to 12-year follow-up of an uncemented total hip arthroplasty (THA) was performed regarding survival, clinical outcome, polyethylene wear and influencing factors on wear. Seventy-two patients (75 Mallory Head uncemented THA) with primary osteoarthritis operated on in 1999 or 2000 were included in the survival study. Mean age at the time of operation was 57.9 years (range 37-70). The survival rate after 11.9 years was 96% (95% Cl 0.89-1.01). In three cases the acetabular component was revised because of extensive polyethylene wear. Fifty-four patients with 57 THAs were available for clinical and radiological analysis. At a mean follow-up time of 10.7 years (range 10-12) the clinical outcome can be considered comparable to other uncemented THA. Mean polyethylene wear was 1.8 mm (range 0.4-3.8) with an annual wear rate of 0.15 mm/y. There was a significant correlation between polyethylene wear and inclination of the cup as well as male gender. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:1362 / 1366
页数:5
相关论文
共 38 条
[1]   Translation, validation, and norming of the Dutch language version of the SF-36 Health Survey in community and chronic disease populations [J].
Aaronson, NK ;
Muller, M ;
Cohen, PDA ;
Essink-Bot, ML ;
Fekkes, M ;
Sanderman, R ;
Sprangers, MAG ;
Velde, AT ;
Verrips, E .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 1998, 51 (11) :1055-1068
[2]   Compendium of Physical Activities: an update of activity codes and MET intensities [J].
Ainsworth, BE ;
Haskell, WL ;
Whitt, MC ;
Irwin, ML ;
Swartz, AM ;
Strath, SJ ;
O'Brien, WL ;
Bassett, DR ;
Schmitz, KH ;
Emplaincourt, PO ;
Jacobs, DR ;
Leon, AS .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) :S498-S516
[3]   Activity levels and polyethylene wear of patients 10 years post hip replacement [J].
Bennett, D. ;
Humphreys, L. ;
O'Brien, S. ;
Kelly, C. ;
Orr, J. ;
Beverland, D. E. .
CLINICAL BIOMECHANICS, 2008, 23 (05) :571-576
[4]   Direct comparison of polyethylene wear in cemented and uncemented acetabular cups [J].
Bjerkholt H. ;
Høvik Ø. ;
Reikerås O. .
Journal of Orthopaedics and Traumatology, 2010, 11 (3) :155-158
[5]   No improvement in long-term wear and revision rates with the second-generation Biomet cup (RingLoc) in young patients 141 hips followed for median 12 years [J].
Boesenach, Bart ;
van der Heide, Huub J. L. ;
Nelissen, Rob G. H. H. .
ACTA ORTHOPAEDICA, 2011, 82 (06) :664-668
[6]   Ten-year results with hydroxyapatite-coated total hip femoral components in patients less than fifty years old - A concise follow-up of a previous report [J].
Capello, WN ;
D'Antonio, JA ;
Feinberg, JR ;
Manley, MT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (05) :885-889
[7]   Population-Based Rates of Revision of Primary Total Hip Arthroplasty: A Systematic Review [J].
Corbett, Kelly L. ;
Losina, Elena ;
Nti, Akosua A. ;
Prokopetz, Julian J. Z. ;
Katz, Jeffrey N. .
PLOS ONE, 2010, 5 (10)
[8]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[9]   Measurement of polyethylene wear in acetabular components inserted with and without cement - A randomized trial [J].
Devane, PA ;
Robinson, EJ ;
Bourne, RB ;
Rorabeck, CH ;
Nayak, NN ;
Horne, JG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (05) :682-689
[10]   Different loss of BMD using uncemented press-fit and whole polyethylene cups fixed with cement -: Repeated DXA studies in 96 hips randomized to 3 types of fixation [J].
Digas, G ;
Kärrholm, J ;
Thanner, J .
ACTA ORTHOPAEDICA, 2006, 77 (02) :218-226