Effectiveness of CFRP Strengthening in Improving Cyclic Compression Response of Slender RC Columns

被引:22
作者
Al-Salloum, Yousef A. [1 ]
Al-Amri, Ghaithan S. [1 ]
Siddiqui, Nadeem A. [1 ]
Almusallam, Tarek H. [1 ]
Abbas, Husain [1 ]
机构
[1] King Saud Univ, Dept Civil Engn, MMB Chair Res & Studies Strengthening & Rehabil S, Riyadh 11421, Saudi Arabia
关键词
Circular columns; Square columns; Cyclic compression; Fiber-reinforced polymer (FRP); Carbon fiber-reinforced polymer (CFRP); Slender columns; Reinforced concrete (RC); Strengthening; FRP-CONFINED CONCRETE; STRESS-STRAIN MODEL; DESIGN; BEHAVIOR; JACKETS; LIMIT;
D O I
10.1061/(ASCE)CC.1943-5614.0000842
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The effectiveness of fiber-reinforced polymer (FRP) based strengthening on the monotonic compression response of reinforced concrete (RC) short columns has been studied extensively. Effectiveness of FRP strengthening in improving cyclic compression response of slender RC circular and square columns is investigated. A total number of 24 slender RC columns of 1,200mm height were cast in two groups of circular and square columns. Specimens of each group had four unstrengthened and eight strengthened columns. Two schemes were followed to strengthen the columns. In the first scheme of strengthening, one layer of carbon FRP (CFRP) sheet was attached to the columns, maintaining CFRP fibers in the transverse direction. In the other strengthening scheme, however, the first two layers of CFRP sheets were externally bonded to the column, keeping the fibers along the height of the column, and then one layer of CFRP sheet was wrapped over the longitudinal sheets with its fibers in the transverse direction. Specimens were tested under eccentric monotonic and cyclic compression loadings. The cyclic compression involved several loading-unloading compression cycles before failure. Test results showed that CFRP strengthening of slender columns is equally effective in cyclic compression as in monotonic compression. A simple formulation is also presented to derive load-moment (P-M) interaction diagrams for FRP-strengthened columns. The prediction complies well with the experiments. The CFRP confinement of RC columns decreases the slenderness limit of the columns and can be reasonably predicted by the recommended equation. This reduction is more in CFRP-confined circular columns than square columns.
引用
收藏
页数:17
相关论文
共 43 条
[1]  
ACI (American Concrete Institute), 2008, 2R ACI 440
[2]   Influence of edge sharpness on the strength of square concrete columns confined with FRP composite laminates [J].
Al-Salloum, Yousef A. .
COMPOSITES PART B-ENGINEERING, 2007, 38 (5-6) :640-650
[3]   Seismic Behavior of As-Built, ACI-Complying, and CFRP-Repaired Exterior RC Beam-Column Joints [J].
Al-Salloum, Yousef A. ;
Almusallam, Tarek H. ;
Alsayed, Saleh H. ;
Siddiqui, Nadeem A. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2011, 15 (04) :522-534
[4]   Experimental and numerical investigation for compression response of CFRP strengthened shape modified wall-like RC column [J].
Alsayed, S. H. ;
Almusallam, T. H. ;
Ibrahim, S. M. ;
Al-Hazmi, N. M. ;
Al-Salloum, Y. A. ;
Abbas, H. .
CONSTRUCTION AND BUILDING MATERIALS, 2014, 63 :72-80
[5]   Reliability of shear-deficient RC beams strengthened with CFRP-strips [J].
Alsayed, Saleh H. ;
Siddiqui, Nadeem A. .
CONSTRUCTION AND BUILDING MATERIALS, 2013, 42 :238-247
[6]  
[Anonymous], 2014, Building Code Requirements for Structural Concrete (ACI 318-14) and Commentary (ACI 318R-14). ACI 318-14
[7]  
[Anonymous], 2014, D3039 ASTM
[8]  
[Anonymous], 2012, C39 ASTM
[9]  
ASTM I, 2012, A370 ASTM
[10]   Axial-flexural interaction in circular FRP-confined reinforced concrete columns [J].
Bisby, Luke ;
Ranger, Michael .
CONSTRUCTION AND BUILDING MATERIALS, 2010, 24 (09) :1672-1681