Radiation-Induced Lens Opacities among Interventional Cardiologists: Retrospective Assessment of Cumulative Eye Lens Doses

被引:20
作者
Struelens, L. [1 ]
Dabin, J. [1 ]
Carinou, E. [2 ]
Askounis, P. [2 ]
Ciraj-Bjelac, O. [3 ]
Domienik-Andrzejewska, J. [4 ]
Berus, D. [5 ]
Padovani, R. [6 ]
Farah, J. [7 ]
Covens, P. [5 ]
机构
[1] Belgian Nucl Res Ctr SCK CEN, Radiat Protect Dosimetry & Calibrat Grp, Mol, Belgium
[2] Greek Atom Energy Commiss EEAE, Dosimetry & Calibrat Dept, Aghia Paraskevi, Greece
[3] Univ Belgrade, Vinca Inst Nucl Sci, Belgrade, Serbia
[4] NIOM, Radiat Protect Dept, PL-91348 Lodz, Poland
[5] Vrije Univ Brussel, Dept Radiat Protect, B-1090 Brussels, Belgium
[6] Abdus Salam Int Ctr Theoret Phys ICTP, Dept Med Phys, I-34151 Trieste, Italy
[7] IRSN, DRPH SDI LEDI, Ionising Radiat Dosimetry Lab, BP-17, F-92262 Fontenay Aux Roses, France
关键词
MONTE-CARLO; PROTECTION; RADIOLOGY; DOSIMETRY; EXTREMITIES; PERSONNEL;
D O I
10.1667/RR14970.1
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study describes the retrospective lens dose calculation methods developed and applied within the European epidemiological study on radiation-induced lens opacities among interventional cardiologists. While one approach focuses on self-reported data regarding working practice in combination with available procedure-specific eye lens dose values, the second approach focuses on the conversion of the individual whole-body dose to eye lens dose. In contrast with usual dose reconstruction methods within an epidemiological study, a protocol is applied resulting in an individual distribution of possible cumulative lens doses for each recruited cardiologist, rather than a single dose estimate. In this way, the uncertainty in the dose estimate (from measurement uncertainty and variability among cardiologists) is represented for each individual. Eye lens dose and whole-body dose measurements have been performed in clinical practice to validate both methods, and it was concluded that both produce acceptable results in the framework of a dose-risk evaluation study. Optimal results were obtained for the dose to the left eye using procedure-specific lens dose data in combination with information collected on working practice. This method has been applied to 421 interventional cardiologists resulting in a median cumulative eye lens dose of 15.1 cSv for the left eye and 11.4 cSv for the right eye. From the individual cumulative eye lens dose distributions obtained for each cardiologist, maxima up to 9-10 Sv were observed, although with low probability. Since whole-body dose values above the lead apron are available for only a small fraction of the cohort and in many cases not for the entire working career, the second method has only been used to benchmark the results from the first approach. This study succeeded in improving the retrospective calculation of cumulative eye lens doses in the framework of radiation-induced risk assessment of lens opacities, but it remains dependent on self-reported information, which is not always reliable for early years. However, the calculation tools developed can also be used to make an assessment of the eye lens dose in current practice. (C) 2018 by Radiation Research Society
引用
收藏
页码:399 / 408
页数:10
相关论文
共 24 条
[1]  
[Anonymous], 2005, 612672005 IEC
[2]  
[Anonymous], 1996, 70341 ISO
[3]  
[Anonymous], 2007, ANN ICRP
[4]   Eye lens dosimetry in interventional cardiology: results of staff dose measurements and link to patient dose levels [J].
Antic, V. ;
Ciraj-Bjelac, O. ;
Rehani, M. ;
Aleksandric, S. ;
Arandjic, D. ;
Ostojic, M. .
RADIATION PROTECTION DOSIMETRY, 2013, 154 (03) :276-284
[5]   EYE LENS EXPOSURE TO MEDICAL STAFF PERFORMING ELECTROPHYSIOLOGY PROCEDURES: DOSE ASSESSMENT AND CORRELATION TO PATIENT DOSE [J].
Ciraj-Bjelac, Olivera ;
Antic, Vojislav ;
Selakovic, Jovana ;
Bozovic, Predrag ;
Arandjic, Danijela ;
Pavlovic, Sinisa .
RADIATION PROTECTION DOSIMETRY, 2016, 172 (04) :475-482
[6]   Risk for Radiation-Induced Cataract for Staff in Interventional Cardiology: Is There Reason for Concern? [J].
Ciraj-Bjelac, Olivera ;
Rehani, Madan M. ;
Sim, Kui Hian ;
Liew, Houng Bang ;
Vano, Eliseo ;
Kleiman, Norman J. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 76 (06) :826-834
[7]   FIRST EURADOS INTERCOMPARISON EXERCISE OF EYE LENS DOSEMETERS FOR MEDICAL APPLICATIONS [J].
Clairand, I. ;
Ginjaume, M. ;
Vanhavere, F. ;
Carinou, E. ;
Daures, J. ;
Denoziere, M. ;
Silva, E. H. ;
Roig, M. ;
Principi, S. ;
Van Rycheghem, L. .
RADIATION PROTECTION DOSIMETRY, 2016, 170 (1-4) :21-26
[8]   The impact of x-ray tube configuration on the eye lens and extremity doses received by cardiologists in electrophysiology room [J].
Domienik, J. ;
Bissinger, A. ;
Zmyslony, M. .
JOURNAL OF RADIOLOGICAL PROTECTION, 2014, 34 (04) :N73-N79
[9]   A study of the dose distribution in the region of the eye lens and extremities for staff working in interventional cardiology [J].
Domienik, J. ;
Brodecki, M. ;
Rusicka, D. .
RADIATION MEASUREMENTS, 2012, 47 (02) :130-138
[10]   Occupational radiation doses to the extremities and the eyes in interventional radiology and cardiology procedures [J].
Efstathopoulos, E. P. ;
Pantos, I. ;
Andreou, M. ;
Gkatzis, A. ;
Carinou, E. ;
Koukorava, C. ;
Kelekis, N. L. ;
Brountzos, E. .
BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (997) :70-77