Numerical study of microwave induced thermoacoustic imaging for initial detection of cancer of breast on anatomically realistic breast phantom

被引:29
|
作者
Rahpeima, Reza [1 ]
Soltani, M. [2 ,3 ,4 ,5 ,6 ]
Kashkooli, Farshad Moradi [2 ,7 ]
机构
[1] KN Toosi Univ Technol, Dept Aerosp Engn, Tehran, Iran
[2] KN Toosi Univ Technol, Dept Mech Engn, Tehran, Iran
[3] KN Toosi Univ Technol, Adv Bioengn Initiat Ctr, Computat Med Ctr, Tehran, Iran
[4] Univ Tehran Med Sci, Canc Biol Res Ctr, Canc Inst Iran, Tehran, Iran
[5] Univ Waterloo, Dept Elect & Comp Engn, Waterloo, ON, Canada
[6] Univ Waterloo, Ctr Biotechnol & Bioengn CBB, Waterloo, ON, Canada
[7] Univ Waterloo, Dept Appl Math, Waterloo, ON, Canada
关键词
Thermoacoustic imaging (TAI); Thermoacoustic tomography; Breast cancer; Anatomically realistic breast phantoms (ARBP); SENSING ADAPTIVE RADAR; DIELECTRIC-PROPERTIES; MR ELASTOGRAPHY; YOUNGS MODULUS; TOMOGRAPHY; TISSUE; RECONSTRUCTION; EXPERIENCE; TUMORS;
D O I
10.1016/j.cmpb.2020.105606
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and objective: Microwave-induced thermoacoustic imaging (MITAI) represents an innovative imaging approach for detection of breast cancer at initial phases by integrating the benefits provided by procedures of microwave and ultrasound imaging. The present investigation examines an innovative three-dimensional numerical modeling of MITAI as a problem with multi-physics nature. Methods: Simulations are performed by the use of COMSOL software. An anatomically realistic breast phantom representing various parts of a real breast, such as three different types of tissue, fibro-connective/glandular, transitional; and fatty, is taken into consideration along with a tumor. This breast phantom with a tumor is irradiated by a 2.45 GHz pulsed rectangular waveguide. The temperature increase and its consequent pressure caused by electromagnetic absorption are analyzed. Results: More temperature increase occurs in the tumor area than in the other parts of the breast, the fact which results in further increase in the pressure in the tumor area than other parts. This makes the tumor distinguishable. The ability of the MITAI process regarding the tumor size, shape (both geometrical shape and spatial orientation), location, the irradiation power level, and the pulse width is also investigated. It is demonstrated that tumor size does not have a significant impact on the efficiency of detection. In fact, very small tumors in the early stages of cancer development (with a radius of 0.25 cm) are also detectable by employing the MITAI technique. The geometrical shape of the tumor does not considerably affect the detecting performance just by itself. The spatial orientation of the tumor actually has a great impact on it. The location of the tumor is an essential factor involved in detection efficiency of MITAI. Tumors located in the fatty tissues would be much easier to be detected than those in the glandular tissues. Moreover, results denote that with augmentation of the irradiation power level or increasing the pulse width, stronger acoustic waves would be produced to make tumor detection easier. Conclusion: These modeling and techniques may be applied aiming for determination of the amount of the generated pressure differences and acoustic pressure magnitude, and can be utilized as an effective prognosticator in practical tests. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] A Heterogeneous Breast Phantom for Microwave Breast Imaging
    Ostadrahimi, Majid
    Reopelle, Ryan
    Noghanian, Sima
    Pistorius, Stephen
    Vahedi, Arman
    Safari, Faezeh
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 2727 - 2730
  • [22] Three-dimensional thermoacoustic imaging for early breast cancer detection
    Ji, Zhong
    Lou, Cunguang
    Yang, Sihua
    Xing, Da
    MEDICAL PHYSICS, 2012, 39 (11) : 6738 - 6744
  • [23] Microwave Imaging for Breast Cancer Detection: The Discrimination of Breast Lesion Morphology
    Zhang, Haoyu
    IEEE ACCESS, 2020, 8 : 107103 - 107111
  • [24] A New Breast Phantom With a Durable Skin Layer for Microwave Breast Imaging
    Garrett, John
    Fear, Elise
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2015, 63 (04) : 1693 - 1700
  • [25] Modeling Realistic Contrast Maps from MRI Images for Microwave Breast Cancer Detection
    Angiulli, G.
    Isernia, T.
    Tringali, S.
    IEEE ANTENNAS AND PROPAGATION MAGAZINE, 2011, 53 (01) : 113 - 122
  • [26] Towards Study on Thermoacoustic Imaging Guided Focused Microwave Therapy for Breast Cancer Treatment
    Saraswat, Srishti
    Tak, Jinpil
    Liang, Min
    Lyu, Cheng
    Witte, Russell S.
    Xin, Hao
    2018 IEEE/MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM - IMS, 2018, : 953 - 956
  • [27] Microwave Induced Thermal Acoustic Imaging Modeling for Potential Breast Cancer Detection
    Wang, Xiong
    Xin, Hao
    Bauer, Daniel
    Witte, Russell
    2011 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION (APSURSI), 2011, : 722 - 725
  • [28] Microwave Imaging for Early Breast Cancer Detection: Current State, Challenges, and Future Directions
    AlSawaftah, Nour
    El-Abed, Salma
    Dhou, Salam
    Zakaria, Amer
    JOURNAL OF IMAGING, 2022, 8 (05)
  • [29] An improved technique based on microwave thermoacoustic method for breast cancer screening
    Alikhani, S.
    Zarei, M.
    Ansari, M. A.
    Niknam, A. R.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2021, 54 (41)
  • [30] Numerical Model For Microwave Induced Thermoacoustic Imaging
    Alzuhiri, Mohand
    Deng, Yiming
    Golkowski, Mark
    Jacobs, Ryan
    2016 UNITED STATES NATIONAL COMMITTEE OF URSI NATIONAL RADIO SCIENCE MEETING (USNC-URSI NRSM), 2016,