Corrosion behaviour of titanium in the presence of Streptococcus mutans

被引:136
作者
Souza, Julio C. M. [1 ,2 ]
Ponthiaux, Pierre [3 ]
Henriques, Mariana [4 ]
Oliveira, Rosario [4 ]
Teughels, Wim [5 ]
Celis, Jean-Pierre [6 ]
Rocha, Luis A. [1 ]
机构
[1] Univ Minho, CT2M, P-4800058 Guimaraes, Portugal
[2] UFP, Sch Hlth Sci FCS, Sch Dent, P-4200250 Oporto, Portugal
[3] Ecole Cent Paris, Chem Engn Lab LGPM, F-92290 Chatenay Malabry, France
[4] Univ Minho, IBB, P-4710057 Braga, Portugal
[5] Katholieke Univ Leuven, Dept Periodontol, B-3000 Louvain, Belgium
[6] Katholieke Univ Leuven, Dept MTM, B-3001 Louvain, Belgium
关键词
Streptococcus mutans; Biofilm; Fluorides; Titanium; Corrosion; SURFACE-TOPOGRAPHY; BIOFILMS; IMPLANT; PARTICLES; ADHESION; FLUORIDE; PLAQUE; MUCIN; WEAR; EIS;
D O I
10.1016/j.jdent.2013.03.008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The main aim of this in vitro study was to evaluate the influence of Streptococcus mutans on the corrosion of titanium. Methods: S. mutans biofilms were formed on commercially pure titanium (CP-Ti) square samples (10 mm x 10 mm x 1 mm) using a culture medium enriched with sucrose. Open circuit potential (OCP) and electrochemical impedance spectroscopy (EIS) measurements were used to evaluate the corrosion behaviour of CP-Ti in the presence of S. mutans in Fusayama's artificial saliva. The corrosion of biofilm-free CP-Ti samples was also evaluated in artificial saliva. Biofilms biomass was measured by spectrophotometry, using crystal violet staining, after 1, 2 and 7 days. Results: The OCP values recorded on CP-Ti in the presence of S. mutans (-0.3 +/- 0.02 V vs. SCE) was lower than those on biofilm-free CP-Ti (-0.1 +/- 0.01 V vs. SCE) after 2 h of immersion in artificial saliva (p < 0.05). That reveals a high reactivity of titanium in presence of S. mutans. Impedance spectra revealed the formation of a compact passive film on titanium in artificial saliva or in the presence of a 2 days old S. mutans biofilm even though the corrosion resistance of CP-Ti has decreased in presence of a S. mutans biofilm. Conclusion: The presence of bacterial colonies, such as S. mutans, negatively affected the corrosion resistance of the titanium. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:528 / 534
页数:7
相关论文
共 35 条
[1]  
Anusavice KJ, 2003, DENT MAT
[2]   The effects of polishing methods on surface morphology, roughness and bacterial colonisation of titanium abutments [J].
Barbour, Michele E. ;
O'Sullivan, Dominic J. ;
Jenkinson, Howard F. ;
Jagger, Daryll C. .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2007, 18 (07) :1439-1447
[3]   Streptococcus mutans biofilm changes surface-topography of resin composites [J].
Beyth, Nurit ;
Bahir, Ran ;
Matalon, Shlomo ;
Domb, Abraham J. ;
Weiss, Ervin I. .
DENTAL MATERIALS, 2008, 24 (06) :732-736
[4]   STABILITY AND OPEN CIRCUIT BREAKDOWN OF THE PASSIVE OXIDE FILM ON TITANIUM [J].
BLACKWOOD, DJ ;
PETER, LM ;
WILLIAMS, DE .
ELECTROCHIMICA ACTA, 1988, 33 (08) :1143-1149
[5]   Persistent acute inflammation at the implant-abutment interface [J].
Broggini, N ;
McManus, LM ;
Hermann, JS ;
Medina, RU ;
Oates, TW ;
Schenk, RK ;
Buser, D ;
Mellonig, JT ;
Cochran, DL .
JOURNAL OF DENTAL RESEARCH, 2003, 82 (03) :232-237
[6]   Electrochemical characterization of cast titanium alloys [J].
Cai, Z ;
Shafer, T ;
Watanabe, I ;
Nunn, ME ;
Okabe, T .
BIOMATERIALS, 2003, 24 (02) :213-218
[7]   Bacterial biofilms: A common cause of persistent infections [J].
Costerton, JW ;
Stewart, PS ;
Greenberg, EP .
SCIENCE, 1999, 284 (5418) :1318-1322
[8]   CORROSION OF GOLD AND AMALGAM PLACED IN CONTACT WITH EACH OTHER [J].
FUSAYAMA, T ;
NOMOTO, S ;
KATAYORI, T .
JOURNAL OF DENTAL RESEARCH, 1963, 42 (05) :1183-&
[9]   Streptococcus mutans surface α-enolase binds salivary mucin MG2 and human plasminogen [J].
Ge, JP ;
Catt, DM ;
Gregory, RL .
INFECTION AND IMMUNITY, 2004, 72 (11) :6748-6752
[10]   Validation of an in vitro biofilm model of supragingival plaque [J].
Guggenheim, B ;
Giertsen, E ;
Schüpbach, P ;
Shapiro, S .
JOURNAL OF DENTAL RESEARCH, 2001, 80 (01) :363-370