High-efficiency wet electrocyclone for removing fine and nanosized particles

被引:31
作者
Lin, Guan-Yu [1 ]
Le-Thi Cuc [1 ]
Lu, Wei [1 ]
Tsai, Chuen-Jinn [1 ]
Chein, Hung-Min [2 ]
Chang, Fang-Tang [2 ]
机构
[1] Natl Chiao Tung Univ, Inst Environm Engn, Hsinchu 300, Taiwan
[2] JG Environm Technol Co Ltd, Longtan Township 325, Taoyuan County, Taiwan
关键词
Deutsch-Anderson equation; Particle control; Nanoparticles; Wet electrocyclone; SOLID-GAS SEPARATION; COLLECTION EFFICIENCY; ELECTROSTATIC PRECIPITATOR; CORONA DISCHARGE; CYCLONE; PERFORMANCE;
D O I
10.1016/j.seppur.2013.04.039
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This study designed and tested a wet electrocyclone with high efficiency for long-term operation. The inner diameter of the collection electrode is 25 cm, and the discharge electrodes consist of seven circular discs with zigzag-shaped edges for particle charging and removal. The tip of the circular saw-type discs is 20 pin in diameter and the tip to the inner wall (collection electrode) spacing is 4 cm. Cleaning water near the inter wall was used to keep the collection electrodes clean. Experimental results showed that the collection efficiency of the present wet electrocyclone decreased with an increasing air flow rate. The efficiency for oleic acid (OA) particles was reduced only slightly from 78-92% to 75-90% for particles from 22.1 to 805 nm in electrical mobility diameter (d(p)) after 6 h of micro-Al2O3 loading test. In the field test, the collection efficiencies of the present wet electrocyclone for submicron SiO2 particles with mass concentration of 20-50 mg/m(3) were also found to keep higher than 93% for continuous 14-day operation. A modified Deutsch-Anderson model was developed to predict the charged particle collection efficiency (eta(elec,p), %) of nanoparticle as well as larger particles. The present model is eta(elec,p) (%) = 1 - exp{-[A(N-De(B)) + C(N-De) + D]} x 100%, where A, B, C and D are regression coefficients, and N-De is the modified Deutsch number. Good agreement was obtained between the present predictions and experimental data. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:99 / 107
页数:9
相关论文
共 40 条
[1]   Electric fields and corona currents in needle-to-meshed plate gaps [J].
Abdel-Salam, M. ;
Nakano, M. ;
Mizuno, A. .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2007, 40 (11) :3363-3370
[2]   Corona discharge in the hyperbolic point-plane configuration: Direct ionization criterion versus approximate formulations [J].
Adamiak, K ;
Atrazhev, V ;
Atten, P .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2005, 12 (05) :1025-1034
[3]   Simulation of corona discharge in point-plane configuration [J].
Adamiak, K ;
Atten, P .
JOURNAL OF ELECTROSTATICS, 2004, 61 (02) :85-98
[4]   Wetted wall cyclone - A novel concept [J].
Ahuja, S. M. .
POWDER TECHNOLOGY, 2010, 204 (01) :48-53
[5]  
[Anonymous], 1988, THESIS HARVARD U BOS
[6]  
CASAL J, 1983, CHEM ENG-NEW YORK, V90, P99
[7]   An experimental study on the performance of a single discharge wire-plate electrostatic precipitator with back corona [J].
Chang, CL ;
Bai, HL .
JOURNAL OF AEROSOL SCIENCE, 1999, 30 (03) :325-340
[8]   Enhanced collection efficiency for cyclone by applying an external electric field [J].
Chen, CJ .
SEPARATION SCIENCE AND TECHNOLOGY, 2001, 36 (03) :499-511
[9]   ELECTROSTATICALLY ENHANCED CYCLONE SEPARATORS [J].
DIETZ, PW .
POWDER TECHNOLOGY, 1982, 31 (02) :221-226
[10]  
El-Mohandes M.T., 1992, IEEE T IND APPL, VIA-21, P518