Fatigue Strength of Angle Shape Shear Connector used in Steel-Concrete Composite Slab

被引:0
作者
Choi, Sung-Min [1 ]
Tateishi, Kazuo [2 ]
Uchida, Daisuke [3 ]
Asano, Koichi [3 ]
Kobayashi, Kiyoshi [3 ]
机构
[1] Nagoya Univ, Dept Civil Engn, Chikusa Ku, Nagoya, Aichi 4648603, Japan
[2] Nagoya Univ, EcoTopia Sci Inst, Chikusa Ku, Nagoya, Aichi 4648603, Japan
[3] Mitsui Engn & Shipbldg Co Ltd, Chuo Ku, Tokyo, Japan
关键词
Composite slab; Angle shape shear connector; Fatigue; Welded joint; Local bending deformation;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Fatigue strength of welded joint between angle shape shear connector and bottom plate in steel-concrete composite slab was investigated by fatigue tests. Fatigue tests were performed on push-out shear specimens. Local stress around the welded joint was also investigated by FEA. In fatigue tests, fatigue cracks initiated and propagated at the welded toe. The fatigue cracks were caused by stress concentration at the welded joints due to the local bending deformation of bottorn plate. This local bending deformation was analytically simulated by FEA carried out on slab members in practice. After these investigations, it was confirmed the stress level at the welded joint was small and much less than the fatigue limit even when the design truck loads were applied.
引用
收藏
页码:199 / 204
页数:6
相关论文
共 3 条
[1]  
Carreira DJ., 1985, ACI J P, V82, P797
[2]  
FUKAZAWA K, 2002, MITSUI ZOSEN TECHNIC, V1, P8
[3]  
*INT I WELD, 2007, FAT DES WELD JOINTS