High Frame-rate Coherent Diverging Wave Imaging with 2-D Motion Compensation

被引:0
|
作者
Nie, Luzhen [1 ]
Carpenter, Thomas M. [1 ]
Cowell, David M. J. [1 ]
McLaughlan, James R. [1 ,2 ]
Cubukcu, Arzu A. [3 ]
Freear, Steven [1 ]
机构
[1] Univ Leeds, Sch Elect & Elect Engn, Ultrasound Grp, Leeds LS2 9JT, W Yorkshire, England
[2] Univ Leeds, Leeds Inst Canc & Pathol, Leeds LS9 7TF, W Yorkshire, England
[3] East Cheshire NHS Trust, Macclesfield SK10 3BL, Cheshire, England
基金
英国工程与自然科学研究理事会;
关键词
CONTRAST ECHOCARDIOGRAPHY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The use of diverging ultrasound waves provides enhanced temporal resolution for cardiac function assessment. However, current image formation techniques using coherent summation, are susceptible to motion artifacts. In this study, we used correlation based 2D motion estimation to perform motion compensation for coherent diverging wave imaging. The accuracy of this motion estimation method was evaluated with Field II simulations, giving root-mean-square velocity errors of 5.9% 0.2% and 19.5% 0.4% in the axial and lateral directions relative to the maximum velocity of 62.8 cm/s. The results of motion estimation were further processed to render the vector flow map and interpret the motion pattern of the disk. Improvement of the B-mode image quality of a 10 cm in vitro tissue mimicking rotating disk was also demonstrated by removing dark imaging artifacts in the compound image.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] High frame-rate imaging and adaptive tracking of shear shock wave formation in the brain: A Fullwave and experimental study
    Espindola, David
    Lee, Stephen
    Pinton, Gianmarco
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [22] FRAME-RATE CONVERSION FOR MULTIVIEW VIDEO EXPLOITING 3D MOTION MODELS
    Gedik, O. Serdar
    Alatan, A. Aydin
    2010 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, 2010, : 1797 - 1800
  • [23] High Frame Rate Imaging with Diverging Beam Transmission and Fourier Reconstruction
    Lu, Jian-yu
    Chen, Hong
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 2221 - 2224
  • [24] High Frame-Rate Imaging Using Swarm of UAV-Borne Radars
    Ding, Jinshan
    Zhang, Kaiwen
    Huang, Xuejun
    Xu, Zhong
    IEEE Transactions on Geoscience and Remote Sensing, 2024, 62 : 1 - 12
  • [25] Multisensor Compressive Sensing for High Frame-Rate Imaging System in the THz Band
    Saqueb, Syed An Nazmus
    Sertel, Kubilay
    IEEE TRANSACTIONS ON TERAHERTZ SCIENCE AND TECHNOLOGY, 2019, 9 (05) : 520 - 523
  • [26] AUTOMATED CATHETER MOTION COMPENSATION IMPROVES 2-D INTRACORONARY ULTRASOUND IMAGING
    HERRINGTON, DM
    VANHORN, M
    ZHU, Y
    YOUNG, T
    SNYDER, WE
    BRADEN, GA
    CIRCULATION, 1994, 90 (04) : 163 - 163
  • [27] High frame-rate intravascular optical frequency-domain imaging in vivo
    Cho, Han Saem
    Jang, Sun-Joo
    Kim, Kyunghun
    Dan-Chin-Yu, Alexey V.
    Shishkov, Milen
    Bouma, Brett E.
    Oh, Wang-Yuhl
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (01): : 223 - 232
  • [28] High Frame-Rate Imaging Using Swarm of UAV-Borne Radars
    Ding, Jinshan
    Zhang, Kaiwen
    Huang, Xuejun
    Xu, Zhong
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2024, 62
  • [29] High-Frame-Rate Echocardiography Using Coherent Compounding With Doppler-Based Motion-Compensation
    Poree, Jonathan
    Posada, Daniel
    Hodzic, Amir
    Tournoux, Francois
    Cloutier, Guy
    Garcia, Damien
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (07) : 1647 - 1657
  • [30] A Low Cost Open Source High Frame-Rate High-Frequency Imaging System
    Brown, J. A.
    Leadbetter, J.
    Leung, M.
    Bezanson, A.
    Adamson, R.
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 545 - 548