Emerging investigators series: frontier review: occurrence and speciation of chromium in drinking water distribution systems

被引:0
|
作者
Chebeir, Michelle [1 ]
Chen, Gongde [1 ]
Liu, Haizhou [1 ]
机构
[1] Univ Calif Riverside, Dept Chem & Environm Engn, Riverside, CA 92521 USA
基金
美国国家科学基金会;
关键词
TRACE INORGANIC CONTAMINANTS; WESTERN MOJAVE DESERT; HEXAVALENT CHROMIUM; STAINLESS-STEEL; CORROSION SCALES; REDUCTION; BEHAVIOR; SOILS; OXIDATION; PIPE;
D O I
10.1039/c6ew00214e
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Chromium can exist as both trivalent Cr(III) and hexavalent Cr(VI) in typical drinking water conditions, with Cr(VI) being of particular concern due to its high toxicity and new regulatory perspectives. This study critically reviewed the occurrence and speciation of chromium in drinking water distribution systems in the U.S., based on a detailed analysis of the up-to-date EPA Unregulated Contaminant Monitoring Rule (UCMR) database. Data show that the nationwide Cr(VI) levels in drinking water ranged from non-detectable to 97 mu g L-1 at the entry point to drinking water distribution systems, and between nondetectable and 67 mu g L-1 at the maximal residence time of distribution systems. Geographic distributions show that higher drinking water Cr(VI) concentrations were observed in Southwest U.S. and were closely associated with the dependence on groundwater as a drinking water source. While Cr(VI) and total chromium concentrations showed either an increase or a decrease between the entry point and the maximal residence time of drinking water distribution systems, they suggested complex physicochemical processes that can act as both sources and sinks of chromium in distribution systems, including the oxidation of Cr(III)-containing solids by residual disinfectants and the adsorption of Cr(VI) by corrosion scales. Time-dependent data analysis revealed that a considerable fraction of Cr(III) at the entry point to distribution systems was inadvertently converted to Cr(VI) by the time the drinking water reached the maximal residence time of distribution systems, and this conversion was positively correlated with the presence of residual disinfectants. Data analyses suggest that the reactivity of downstream water distribution should be managed to control chromium in tap water.
引用
收藏
页码:906 / 914
页数:9
相关论文
共 50 条
  • [21] Emerging contaminants migration from pipes used in drinking water distribution systems: a review of the scientific literature
    Mohammadi, Azam
    Dobaradaran, Sina
    Schmidt, Torsten C.
    Malakootian, Mohammad
    Spitz, Joerg
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2022, 29 (50) : 75134 - 75160
  • [22] Occurrence and Spatial Distribution of Volatile Organic Compounds in Urban Drinking Water Distribution Systems
    Xu M.-J.
    Wang H.-L.
    Li C.-M.
    Xu X.
    Wang D.-H.
    Wang, Dong-Hong (dhwang@rcees.ac.cn), 2018, Science Press (39): : 655 - 662
  • [23] Occurrence and removal of emerging contaminants in drinking water in California
    Loraine, Gregory
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245
  • [24] Speciation and distribution of trihalomethanes in the drinking water of Hong Kong
    Yu, JC
    Cheng, LN
    ENVIRONMENT INTERNATIONAL, 1999, 25 (05) : 605 - 611
  • [25] Emerging investigators series: a critical review of decision support systems for water treatment: making the case for incorporating climate change and climate extremes
    Raseman, William J.
    Kasprzyk, Joseph R.
    Rosario-Ortiz, Fernando L.
    Stewart, Jenna R.
    Livneh, Ben
    ENVIRONMENTAL SCIENCE-WATER RESEARCH & TECHNOLOGY, 2017, 3 (01) : 18 - 36
  • [26] Effects of disinfectants and particles on the occurrence of different microorganisms in drinking water distribution systems
    Huo, Lixin
    Pan, Linlin
    Chen, Ruya
    Shi, Baoyou
    Wang, Haibo
    He, Shouyang
    ENVIRONMENTAL SCIENCE-WATER RESEARCH & TECHNOLOGY, 2021, 7 (05) : 983 - 992
  • [27] Bacteriology of drinking water distribution systems: an integral and multidimensional review
    G. Liu
    J. Q. J. C. Verberk
    J. C. Van Dijk
    Applied Microbiology and Biotechnology, 2013, 97 : 9265 - 9276
  • [28] Opportunistic Pathogens in Drinking Water Distribution Systems-A Review
    Lechevallier, Mark W.
    Prosser, Toby
    Stevens, Melita
    MICROORGANISMS, 2024, 12 (05)
  • [29] Bacteriology of drinking water distribution systems: an integral and multidimensional review
    Liu, G.
    Verberk, J. Q. J. C.
    Van Dijk, J. C.
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2013, 97 (21) : 9265 - 9276
  • [30] Chromium redox chemistry in drinking water systems
    Lai, Han
    McNeill, Laurie S.
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2006, 132 (08): : 842 - 851