Inpatient long-term video-electroencephalographic monitoring event capture audiovisual diagnostic quality

被引:1
作者
Terman, Samuel Waller [1 ,6 ]
O'Kula, Susanna S. [2 ,3 ]
Asmar, Melissa Marie [4 ,5 ]
Davis, Kathryn A. [5 ]
Gazzola, Deana M. [3 ]
Lesanu, Rodica [1 ]
George, Laura [1 ]
Selwa, Linda M. [1 ]
Glynn, Simon M. [1 ]
Hill, Chloe E. [1 ]
机构
[1] Univ Michigan, Dept Neurol, Ann Arbor, MI USA
[2] State Univ New York Downstate Hlth Sci Univ, Dept Neurol, Brooklyn, NY USA
[3] NYU, Dept Neurol, New York, NY USA
[4] Emory Univ, Dept Neurol, Atlanta, GA USA
[5] Univ Penn, Dept Neurol, Philadelphia, PA USA
[6] Univ Michigan, Dept Neurol, Taubman 1st Floor,Recept C,1500 Med Ctr Dr,SPC 531, Ann Arbor, MI 48109 USA
关键词
EEG; Quality; Inpatient monitoring; Seizures; EPILEPSY; SAFETY; UNITS;
D O I
10.1016/j.yebeh.2022.108947
中图分类号
B84 [心理学]; C [社会科学总论]; Q98 [人类学];
学科分类号
03 ; 0303 ; 030303 ; 04 ; 0402 ;
摘要
Objectives: Long-term video-electroencephalographic monitoring (LTVEM) represents the gold-standard method to evaluate whether events represent electrographic seizures, but limited work has evaluated the quality of inpatient event capture. We evaluated the frequency of audiovisual factors impairing the ideal electroclinical correlation of seizure-like episodes during LTVEM.Methods: We retrospectively reviewed consecutive inpatient LTVEM studies (11/2019-12/2019) from three academic epilepsy centers. We evaluated all pushbutton events for audiovisual characteristics such as whether the event was narrated, whether the patient was blocked on camera, and what diagnostic challenges impaired the electroencephalographer's ability to understand either the reason the event but-ton was pushed or clinical semiology ("electroclinical correlation"). We determined the percent of events and studies with each outcome.Results: There were 154 studies with 520 pushbutton events. The pushbutton was most commonly acti-vated by patients (41%), followed by nurses (31%) or family (17%). Twenty-nine percent of events repre-sented electrographic seizures, and 78% occurred in the Epilepsy Monitoring Unit. The reason for the push was not stated in 45% of events, and inadequate narration impaired electroclinical correlation in 19% of events. At least one relevant part of the patient's body was blocked during 12% of events, but this impaired electroclinical correlation in only 1% of events. There was at least one factor impairing electro-clinical correlation in 21% of events, most commonly due to incomplete narration (N = 99), lights off (N = 15), or blankets covering the patient (N = 15). At least one factor impaired electroclinical correlation for any event in 36% of studies.Conclusion: Audiovisual factors impairing the electroencephalographer's ability to render an electroclin-ical correlation were common, particularly related to inadequate narration from bedside observers to explain the reason for pushing the button or event semiology. Future efforts to develop targeted counter-measures should address narration challenges and improve inpatient seizure monitoring quality metrics. (c) 2022 Elsevier Inc. All rights reserved.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] From clinical observation to long-term monitoring:: Diagnostic developments in conservative epileptology
    Ried, S
    Hilfiker, P
    Mothersill, IW
    Krämer, G
    EPILEPSIA, 2000, 41 : S2 - S9
  • [22] Predictors of focal to bilateral tonic-clonic seizures during long-term video-EEG monitoring
    Pensel, Max C.
    Schnuerch, Martin
    Elger, Christian E.
    Surges, Rainer
    EPILEPSIA, 2020, 61 (03) : 489 - 497
  • [23] Usefulness of long-term video-EEG monitoring in children at a tertiary care center
    Onay, Selin
    Yalnizoglu, Dilek
    Topcu, Meral
    Turanli, Guzide
    TURKISH JOURNAL OF PEDIATRICS, 2013, 55 (06) : 591 - 597
  • [24] A critical appraisal on the utility of long-term video-EEG monitoring in older adults
    Baheti, Neeraj N.
    Radhakrishnan, Ashalatha
    Radhakrishnan, Kurupath
    EPILEPSY RESEARCH, 2011, 97 (1-2) : 12 - 19
  • [25] Outpatient long-term video EEG as new diagnostic approach in Germany: results of a feasibility study
    Meisel, Christian
    Holtkamp, Martin
    Vock, Simon
    NERVENARZT, 2023, 94 (06): : 519 - 524
  • [26] Long-term video-EEG monitoring and interictal epileptiform abnormalities
    Goldstein, Lilach
    Margiotta, Megan
    Guina, Maria Lourdes
    Sperling, Michael R.
    Nei, Maromi
    EPILEPSY & BEHAVIOR, 2020, 113
  • [27] The role of patient companions in long-term video-EEG monitoring
    Dericioglu, N
    Albakir, M
    Saygi, S
    SEIZURE-EUROPEAN JOURNAL OF EPILEPSY, 2000, 9 (02): : 124 - 127
  • [28] Remote and Long-Term Self-Monitoring of Electroencephalographic and Noninvasive Measurable Variables at Home in Patients With Epilepsy (EEG@HOME): Protocol for an Observational Study
    Biondi, Andrea
    Laiou, Petroula
    Bruno, Elisa
    Viana, Pedro F.
    Schreuder, Martijn
    Hart, William
    Nurse, Ewan
    Pal, Deb K.
    Richardson, Mark P.
    JMIR RESEARCH PROTOCOLS, 2021, 10 (03):
  • [29] Long-Term Follow-Up of Colonoscopy Quality Monitoring
    Patel, Feenalie
    Dilly, Christen
    Fayad, Nabil
    Marri, Smitha
    Eckert, George J.
    Kahi, Charles
    CLINICAL AND TRANSLATIONAL GASTROENTEROLOGY, 2023, 14 (09) : e00608
  • [30] The role of long-term video-EEG monitoring in the diagnosis of childhood epilepsies
    Lorincz-Molnar, Timea
    Siegler, Zsuzsa
    Hegyi, Marta
    Jakus, Rita
    Bodo, Timea
    Kormos, Eszter
    Fogarasi, Andras
    ORVOSI HETILAP, 2024, 165 (19) : 722 - 726