Continuous Monitoring of Central Venous Oxygen Saturation (Pediasat) in Pediatric Patients Undergoing Cardiac Surgery: A Validation Study of a New Technology

被引:12
|
作者
Ranucci, Marco [1 ]
Isgro, Giuseppe [1 ]
De la Torre, Teresa [1 ]
Romitti, Federica [1 ]
De Benedetti, Donatella [1 ]
Carlucci, Concetta [1 ]
Kandil, Hassan [1 ]
Ballotta, Andrea [1 ]
机构
[1] IRCCS Policlin S Donato, Dept Cardiothorac Vasc Anesthesia & Intens Care, Milan, Italy
关键词
cardiac surgery; oxygen saturation; monitoring; pediatrics;
D O I
10.1053/j.jvca.2008.04.003
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: Mixed venous oxygen saturation and central venous oxygen saturation are considered possible indicators of the adequacy of oxygen delivery with respect to the oxygen needs of critically ill adult and pediatric patients. The present study was aimed at validating the accuracy of a new technology (Pediasat central venous catheter) in providing a continuous measurement of the central venous oxygen saturation in pediatric patients. Design: A prospective observational study. Participants: Thirty pediatric patients (age, 6 days-9 years) undergoing cardiac operations. Data obtained with the Pediasat during and after the operation were compared with simultaneously collected venous blood samples analyzed with standard laboratory techniques. Setting: A clinical research hospital. Interventions: None. Measurements and Main Results: A Bland and Altman analysis was performed on 30 matched sets of data collected before cardiopulmonary bypass, and during the intensive care unit stay. Before cardiopulmonary bypass, there was a bias of 0.003, with lower and upper limits of agreement, -5.84 and 5.84 (percentage error, 17.3%). During cardiopulmonary bypass, the bias was 0.57 and lower and upper limits of agreement were -7.7 and 8.7 (percentage error, 23.2%). At 2 hours after the arrival in the intensive care unit, the bias was -0.6 and the lower and upper limits of agreement were -8 and 6.8 (percentage error, 20.3%). Conclusions: Because of the minimal bias and the acceptable value of percentage error, the Pediasat may be considered as an accurate tool for the continuous measurement of the central venous oxygen saturation in neonates and pediatric patients during and after cardiac operations. (C) 2008 Elsevier Inc. All rights reserved
引用
收藏
页码:847 / 852
页数:6
相关论文
共 50 条
  • [41] CONTINUOUSLY MONITORED CENTRAL VENOUS OXYGEN SATURATION AFTER PEDIATRIC OPEN HEART SURGERY
    Fernandez, Richard
    Kane, Jason
    Backer, Carl
    Goodman, Denise
    CRITICAL CARE MEDICINE, 2010, 38 (12) : U61 - U61
  • [42] Single transpulmonary thermodilution and continuous monitoring of central venous oxygen saturation during off-pump coronary surgery
    Smetkin, A. A.
    Kirov, M. Y.
    Kuzkov, V. V.
    Lenkin, A. I.
    Eremeev, A. V.
    Slastilin, V. Y.
    Borodin, V. V.
    Bjertnaes, L. J.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2009, 53 (04) : 505 - 514
  • [43] Reliability of continuous jugular venous bulb hemoglobin oxygen saturation during cardiac surgery
    Anastasiou, E
    Gerolioliou, K
    Karakoulas, K
    Peftoulidou, M
    Giala, M
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1999, 13 (03) : 276 - 279
  • [44] CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION DURING AORTIC-SURGERY
    SHENAQ, SA
    CASAR, G
    CHELLY, JE
    OTT, H
    CRAWFORD, ES
    CHEST, 1987, 92 (05) : 796 - 799
  • [45] CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION DURING ANESTHESIA FOR PULMONARY SURGERY
    SAFRAN, D
    JOURNOIS, D
    HUBSCH, JP
    CASTELAIN, MH
    BARRIER, G
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 1989, 8 (06): : 682 - 687
  • [46] CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION IN CRITICALLY ILL PATIENTS
    BAELE, PL
    MCMICHAN, JC
    MARSH, HM
    SILL, JC
    SOUTHORN, PA
    ANESTHESIA AND ANALGESIA, 1982, 61 (06): : 513 - 517
  • [47] CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION IN HEMODYNAMICALLY UNSTABLE PATIENTS
    BIRMAN, H
    HAQ, A
    HEW, E
    ABERMAN, A
    CHEST, 1984, 86 (05) : 753 - 756
  • [48] Central venous saturation estimates oxygen extraction rate in cardiac surgical patients
    Sander, M
    von Heymann, C
    Foer, A
    Doepke, A
    Spies, CD
    Dushe, S
    Konertz, WF
    CRITICAL CARE MEDICINE, 2005, 33 (12) : A55 - A55
  • [49] Prediction of cardiac index by central venous oxygen saturation in patients with septic shock
    Perner, A.
    White, J.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2007, 51 : 25 - 25
  • [50] Continuous jugular bulb venous oxygen saturation validation and variations during intracranial aneurysm surgery
    Clavier, N
    Schurando, P
    Raggueneau, JL
    Payen, DM