Continuous Monitoring of Central Venous Oxygen Saturation (Pediasat) in Pediatric Patients Undergoing Cardiac Surgery: A Validation Study of a New Technology

被引:12
|
作者
Ranucci, Marco [1 ]
Isgro, Giuseppe [1 ]
De la Torre, Teresa [1 ]
Romitti, Federica [1 ]
De Benedetti, Donatella [1 ]
Carlucci, Concetta [1 ]
Kandil, Hassan [1 ]
Ballotta, Andrea [1 ]
机构
[1] IRCCS Policlin S Donato, Dept Cardiothorac Vasc Anesthesia & Intens Care, Milan, Italy
关键词
cardiac surgery; oxygen saturation; monitoring; pediatrics;
D O I
10.1053/j.jvca.2008.04.003
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: Mixed venous oxygen saturation and central venous oxygen saturation are considered possible indicators of the adequacy of oxygen delivery with respect to the oxygen needs of critically ill adult and pediatric patients. The present study was aimed at validating the accuracy of a new technology (Pediasat central venous catheter) in providing a continuous measurement of the central venous oxygen saturation in pediatric patients. Design: A prospective observational study. Participants: Thirty pediatric patients (age, 6 days-9 years) undergoing cardiac operations. Data obtained with the Pediasat during and after the operation were compared with simultaneously collected venous blood samples analyzed with standard laboratory techniques. Setting: A clinical research hospital. Interventions: None. Measurements and Main Results: A Bland and Altman analysis was performed on 30 matched sets of data collected before cardiopulmonary bypass, and during the intensive care unit stay. Before cardiopulmonary bypass, there was a bias of 0.003, with lower and upper limits of agreement, -5.84 and 5.84 (percentage error, 17.3%). During cardiopulmonary bypass, the bias was 0.57 and lower and upper limits of agreement were -7.7 and 8.7 (percentage error, 23.2%). At 2 hours after the arrival in the intensive care unit, the bias was -0.6 and the lower and upper limits of agreement were -8 and 6.8 (percentage error, 20.3%). Conclusions: Because of the minimal bias and the acceptable value of percentage error, the Pediasat may be considered as an accurate tool for the continuous measurement of the central venous oxygen saturation in neonates and pediatric patients during and after cardiac operations. (C) 2008 Elsevier Inc. All rights reserved
引用
收藏
页码:847 / 852
页数:6
相关论文
共 50 条
  • [21] Prolonged Central Venous Desaturation Measured by Continuous Oximetry Is Associated with Adverse Outcomes in Pediatric Cardiac Surgery
    Crowley, Ryan
    Sanchez, Elizabeth
    Ho, Jonathan K.
    Lee, Kate J.
    Schwarzenberger, Johanna
    Marijic, Jure
    Sopher, Michael
    Mahajan, Aman
    ANESTHESIOLOGY, 2011, 115 (05) : 1033 - 1043
  • [22] Discrepancy Between Superior Vena Cava Oxygen Saturation and Mixed Venous Oxygen Saturation Can Predict Postoperative Complications in Cardiac Surgery Patients
    Suehiro, Koichi
    Tanaka, Katsuaki
    Matsuura, Tadashi
    Funao, Tomoharu
    Yamada, Tokuhiro
    Mori, Takashi
    Nishikawa, Kiyonobu
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2014, 28 (03) : 528 - 533
  • [23] CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION FOR DETECTING ALTERATIONS IN CARDIAC-OUTPUT AFTER DISCONTINUATION OF CARDIOPULMONARY BYPASS
    INOMATA, S
    NISHIKAWA, T
    TAGUCHI, M
    BRITISH JOURNAL OF ANAESTHESIA, 1994, 72 (01) : 11 - 16
  • [24] Effectiveness of securing central venous catheters with topical tissue adhesive in patients undergoing cardiac surgery: a randomized controlled pilot study
    Naruemol Prachanpanich
    Sunthiti Morakul
    Napanont Kiatmongkolkul
    BMC Anesthesiology, 21
  • [25] Effectiveness of securing central venous catheters with topical tissue adhesive in patients undergoing cardiac surgery: a randomized controlled pilot study
    Prachanpanich, Naruemol
    Morakul, Sunthiti
    Kiatmongkolkul, Napanont
    BMC ANESTHESIOLOGY, 2021, 21 (01)
  • [26] Central Venous-to-Arterial Carbon Dioxide Partial Pressure Difference in Patients Undergoing Cardiac Surgery is Not Related to Postoperative Outcomes
    Guinot, Pierre-Gregoire
    Badoux, Louise
    Bernard, Eugenie
    Abou-Arab, Osama
    Lorne, Emmanuel
    Dupont, Herve
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2017, 31 (04) : 1190 - 1196
  • [27] Real-time continuous glucose monitoring in pediatric patients during and after cardiac surgery
    Piper, Hannah G.
    Alexander, Jamin L.
    Shukla, Avinash
    Pigula, Frank
    Costello, John M.
    Laussen, Peter C.
    Jaksic, Tom
    Agus, Michael S. D.
    PEDIATRICS, 2006, 118 (03) : 1176 - 1184
  • [28] Validation of the Masimo O3™ regional oximetry device in pediatric patients undergoing cardiac surgery
    Lee, Ji-Hyun
    Song, In-Sun
    Kang, Pyoyoon
    Ji, Sang-Hwan
    Jang, Young-Eun
    Kim, Eun-Hee
    Kim, Hee-Soo
    Kim, Jin-Tae
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (06) : 1703 - 1709
  • [29] Validation of the Masimo O3™ regional oximetry device in pediatric patients undergoing cardiac surgery
    Ji-Hyun Lee
    In-Sun Song
    Pyoyoon Kang
    Sang-Hwan Ji
    Young-Eun Jang
    Eun-Hee Kim
    Hee-Soo Kim
    Jin-Tae Kim
    Journal of Clinical Monitoring and Computing, 2022, 36 : 1703 - 1709
  • [30] Reduced incidence of atrial fibrillation after cardiac surgery by continuous wireless monitoring of oxygen saturation on the normal ward and resultant oxygen therapy for hypoxia
    Kisner, Dilek
    Wilhelm, Markus J.
    Messerli, Michael S.
    Zuend, Gregor
    Genoni, Michele
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2009, 35 (01) : 111 - 115