Does VMAT for treatment of NSCLC patients increase the risk of pneumonitis compared to IMRT? - A planning study

被引:19
作者
Bertelsen, Anders [1 ,2 ]
Hansen, Olfred [3 ]
Brink, Carsten [1 ,2 ]
机构
[1] Univ So Denmark, Inst Clin Res, Odense, Denmark
[2] Odense Univ Hosp, Lab Radiat Phys, DK-5000 Odense, Denmark
[3] Odense Univ Hosp, Dept Oncol, DK-5000 Odense, Denmark
关键词
DOSE CALCULATION ALGORITHMS; 3-DIMENSIONAL CONFORMAL RADIOTHERAPY; CONCURRENT CHEMOTHERAPY; LUNG; THERAPY; PHOTON; IRRADIATION; TOXICITY; HEART; ARC;
D O I
10.3109/0284186X.2011.648341
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background. Volumetric modulated arc therapy (VMAT) for treatment of non-small cell lung cancer (NSCLC) patients potentially changes the risk of radiation-induced pneumonitis (RP) compared to intensity modulated radiation therapy (IMRT) if the dose to the healthy lung is changed significantly. In this study, clinical IMRT plans were used as starting point for VMAT optimization and differences in risk estimates of RP between the two plan types were evaluated. Material and methods. Fifteen NSCLC patients prescribed 66 Gy in 2 Gy fractions were planned with IMRT and subsequently with single arc VMAT. Dose metrics were evaluated for target and lung together with population averaged dose volume histograms. The risk of RP was calculated using normal tissue complication probability (NTCP) models. Finally, applicability of the plans was tested through delivery on an Elekta accelerator. Results. When changing from IMRT to VMAT only modest differences were observed in the dose to the lung and target volume. On average, fractions of lung irradiated to doses between 18 Gy and 48 Gy were statistically signifi cant reduced using VMAT compared to IMRT. For the fraction of lung receiving more than 20 Gy the reduction was 1.2% percentage points: (range -0.6 2.6%). The evaluated toxicity were smaller with VMAT compared to IMRT, however only modest differences were observed in the NTCP values. The plans were delivered without any problems. The average beam on time with VMAT was 83 s. This was a reduction of 141 s (ranging from 37 s to 216 s) compared to IMRT. Conclusions. Using IMRT as reference for the VMAT optimization it was possible to implement VMAT in the clinic with no increase in estimated risk of RP. Thus, toxicity is not expected to be a hindrance to using VMAT and will profit from the shorter delivery time with VMAT compared to IMRT.
引用
收藏
页码:752 / 758
页数:7
相关论文
共 26 条
  • [1] Radiation dose response of normal lung assessed by Cone Beam CT - A potential tool for biologically adaptive radiation therapy
    Bertelsen, Anders
    Schytte, Tine
    Bentzen, Soren M.
    Hansen, Olfred
    Nielsen, Morten
    Brink, Carsten
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 100 (03) : 351 - 355
  • [2] Validation of a new control system for Elekta accelerators facilitating continuously variable dose rate
    Bertelsen, Anders
    Lorenzen, Ebbe L.
    Brink, Carsten
    [J]. MEDICAL PHYSICS, 2011, 38 (08) : 4802 - 4810
  • [3] Single Arc Volumetric Modulated Arc Therapy of head and neck cancer
    Bertelsen, Anders
    Hansen, Christian R.
    Johansen, Jorgen
    Brink, Carsten
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 95 (02) : 142 - 148
  • [4] Single-Arc IMRT?
    Bortfeld, Thomas
    Webb, Steve
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (01) : N9 - N20
  • [5] Development and evaluation of an efficient approach to volumetric arc therapy planning
    Bzdusek, Karl
    Friberger, Henrik
    Eriksson, Kjell
    Hardemark, Bjorn
    Robinson, David
    Kaus, Michael
    [J]. MEDICAL PHYSICS, 2009, 36 (06) : 2328 - 2339
  • [6] CERR: A computational environment for radiotherapy research
    Deasy, JO
    Blanco, AI
    Clark, VH
    [J]. MEDICAL PHYSICS, 2003, 30 (05) : 979 - 985
  • [7] On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities:: comparison with Monte Carlo calculations
    Fogliata, Antonella
    Vanetti, Eugenio
    Albers, Dirk
    Brink, Carsten
    Clivio, Alessandro
    Knoos, Tommy
    Nicolini, Giorgia
    Cozzi, Luca
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (05) : 1363 - 1385
  • [8] The IASLC lung cancer staging project: Proposals for the revision of he TNM stage groupings in the forthcoming (seventh) edition of the TNM classification of malignant tumours
    Goldstraw, Peter
    Crowley, John
    Chansky, Kari
    Giroux, Dorothy J.
    Groome, Patti A.
    Rami-Porta, Ramon
    Postmus, Pieter E.
    Rusch, Valerie
    Sobin, Leslie
    [J]. JOURNAL OF THORACIC ONCOLOGY, 2007, 2 (08) : 706 - 714
  • [9] Investigation of respiration induced intra- and inter-fractional tumour motion using a standard Cone Beam CT
    Gottlieb, Karina L.
    Hansen, Christian R.
    Hansen, Olfred
    Westberg, Jonas
    Brink, Carsten
    [J]. ACTA ONCOLOGICA, 2010, 49 (07) : 1192 - 1198
  • [10] Clinical dose-volume histogram analysis for pneumonitis after 3D treatment for non-small cell lung cancer (NSCLC)
    Graham, MV
    Purdy, JA
    Emami, B
    Harms, W
    Bosch, W
    Lockett, MA
    Perez, CA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (02): : 323 - 329