An anatomical study of normal meniscal roots with isotropic 3D MRI at 3 T

被引:17
|
作者
Ren, A-Hong [1 ,2 ]
Zheng, Zhuo-Zhao [1 ]
Shang, Yao [1 ]
Tian, Chun-Yan [1 ]
机构
[1] Peking Univ Third Hosp, Dept Radiol, Beijing 100191, Peoples R China
[2] Beijing Daxing Hosp, Dept Radiol, Beijing 102600, Peoples R China
关键词
Magnetic resonance imaging; Meniscus; Root; Knee joint; Anatomy; LATERAL MENISCUS; KNEE; ARTHROSCOPY; DIAGNOSIS; TEAR; RECONSTRUCTION; EXTRUSION; POSITION;
D O I
10.1016/j.ejrad.2012.03.015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To clarify the morphological features of normal meniscal roots on magnetic resonance (MR) imaging with an isotropic 3D proton density-weighted (PDW) sequence. Materials: 3D PDW MR was performed in sixty-two patients at 3 T before knee arthroscopy. MR images of 34 normal medial menisci and 33 intact lateral menisci confirmed by arthroscopy were retrospectively evaluated. MR signals, insertion sites, dimensions and courses of four meniscal roots were recorded. Results: The anterior root of medial meniscus (ARMM) was typically hypointense, while the posterior root of medial meniscus (PRMM) and the anterior root of lateral meniscus (ARLM) were prone to be hyperintense or showing a comblike signal, and the posterior root of lateral meniscus (PRLM) was usually hypointense or comblike on PDW MR images. ARMM and PRLM had more complex and diverse insertion patterns than ARLM and PRMM. There were significant statistical differences of the lengths, widths, heights and course angles among four meniscal roots (all P < 0.001). Conclusions: The signal intensity of each meniscal root can be hypointense, hyperintense, or comblike on 3D PDW MR images. ARMM and PRLM have more complex and diverse insertion patterns than ARLM and PRMM. The dimensions and courses of four meniscal roots all differ. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E783 / E788
页数:6
相关论文
共 50 条
  • [21] 3D MRI of the Rheumatic Diseases
    Ezzati, Fatemeh
    Chalian, Majid
    Pezeshk, Parham
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2021, 25 (03) : 425 - 432
  • [22] Main anatomical features of the calcarine sulcus: a 3D magnetic resonance imaging at 3T study
    Ahmad Rachid El Mohamad
    Laurent Tatu
    Thierry Moulin
    Sami Fadoul
    Fabrice Vuillier
    Surgical and Radiologic Anatomy, 2019, 41 : 181 - 186
  • [23] Main anatomical features of the calcarine sulcus: a 3D magnetic resonance imaging at 3T study
    El Mohamad, Ahmad Rachid
    Tatu, Laurent
    Moulin, Thierry
    Fadoul, Sami
    Vuillier, Fabrice
    SURGICAL AND RADIOLOGIC ANATOMY, 2019, 41 (02) : 181 - 186
  • [24] Isotropic 3D cardiac cine MRI allows efficient sparse segmentation strategies based on 3D surface reconstruction
    Odille, Freddy
    Bustin, Aurelien
    Liu, Shufang
    Chen, Bailiang
    Vuissoz, Pierre-Andre
    Felblinger, Jacques
    Bonnemains, Laurent
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (05) : 2665 - 2675
  • [25] The contribution of 3D quantitative meniscal and cartilage measures to variation in normal radiographic joint space width-Data from the Osteoarthritis Initiative healthy reference cohortMelanie
    Roth, Melanie
    Wirth, Wolfgang
    Emmanuel, Katja
    Culvenor, Adam G.
    Eckstein, Felix
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 87 : 90 - 98
  • [26] A balance between native footprint coverage and overlap of the anterolateral meniscal root in tibial tunnel positioning during anterior cruciate ligament reconstruction: A 3D MRI study
    Oshima, Takeshi
    Putnis, Sven
    Grasso, Samuel
    Lim, Yoong Ping
    Oshima, Megumi
    Parker, David Anthony
    KNEE, 2023, 41 : 106 - 114
  • [27] Comparison of 2D Thin Section Dixon, 3D Isotropic SPACE, and 2D T2-Weighted Sequences in Ankle MRI
    Ahn, Tae Ran
    Jeong, Yu Mi
    Jeon, Ji Young
    Park, So Hyun
    Lee, Sheen-Woo
    INVESTIGATIVE MAGNETIC RESONANCE IMAGING, 2022, 26 (04) : 284 - 293
  • [28] Comparison of a T2*W. 3D CISS and a T2 W. 3D turbo spin echo sequence for the anatomical study of facial and vestibulocochlear nerves
    Held, P
    Fründ, R
    Seitz, J
    Nitz, W
    Haffke, T
    Hees, H
    Waldeck, A
    JOURNAL OF NEURORADIOLOGY, 2000, 27 (03) : 173 - 178
  • [29] Spherical 3D isotropic wavelets
    Lanusse, F.
    Rassat, A.
    Starck, J. -L.
    ASTRONOMY & ASTROPHYSICS, 2012, 540
  • [30] Reliability of 3D localisation of ACL attachments on MRI: comparison using multi-planar 2D versus high-resolution 3D base sequences
    Swami, Vimarsha Gopal
    Cheng-Baron, June
    Hui, Catherine
    Thompson, Richard B.
    Jaremko, Jacob Lester
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (04) : 1206 - 1214