Design On-line Monitoring and Sensitive Fault Detection for Three Phase Induction Motor

被引:0
|
作者
Asfani, D. A. [1 ]
Mubarok, H. Z. [1 ]
Musthofa, Arif [1 ]
Negara, I. M. Yulistya [1 ]
机构
[1] Inst Teknol Sepuluh Nopember, Dept Elect Engn, Surabaya 60111, Indonesia
关键词
Induction motor monitoring; inter-turn short circuit; STATOR; FAILURES;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
On-line monitoring system is one of the solutions to avoid catastrophic failure in machine, including induction motor. The most common fault in induction motor is stator winding failures that initiated by inter-turn short circuit. In this paper, induction motor monitoring and fault detection system is proposed based on microcontroller which is displayed on computer monitor. Several measurement variables are displayed in on-line monitoring interface such as voltage, current, speed, and stator temperature. Moreover, the diagnostic system is developed to detect inter-turn short circuit. Based on the testing result, the proposed system is successfully to detect one-turn short circuit fault or less than one percent of stator winding.
引用
收藏
页码:1869 / 1874
页数:6
相关论文
共 50 条
  • [1] An unsupervised, on-line system for induction motor fault detection using stator current monitoring
    Schoen, RR
    Lin, BK
    Habetler, TG
    Schlag, JH
    Farag, S
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1995, 31 (06) : 1280 - 1286
  • [2] An On-Line Condition Monitoring System for Incipient Fault Detection in Double-Cage Induction Motor
    Hmida, Mohamed Ali
    Braham, Ahmed
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2018, 67 (08) : 1850 - 1858
  • [3] On-line monitoring and fault detection
    Seem, JE
    House, JM
    Monroe, RH
    ASHRAE JOURNAL, 1999, 41 (07) : 21 - 26
  • [4] Model-based and wavelet approaches to induction motor on-line fault detection
    Combastel, C
    Lesecq, S
    Petropol, S
    Gentil, S
    CONTROL ENGINEERING PRACTICE, 2002, 10 (05) : 493 - 509
  • [5] Unsupervised neural-network-based algorithm for an on-line diagnosis of three-phase induction motor stator fault
    Martins, J. F.
    Pires, V. Fernao
    Pires, A. J.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (01) : 259 - 264
  • [6] On-Line Detection of High Resistance Connections with Inverse-Sequence Regulators in Three Phase Induction Motor Drives
    Zarri, L.
    Mengoni, M.
    Gritli, Y.
    Tani, A.
    Filippetti, F.
    Lee, Sang Bin
    2013 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2013, : 4426 - 4431
  • [7] Summary of on-line condition monitoring and fault diagnostics for 3-phase induction motors
    Liu, Z.X.
    Zhang, Z.
    Yin, X.G.
    Wuhan Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Wuhan University of Science and Technology (Natural Science Edition), 2001, 24 (03):
  • [8] Advanced fault detection technique of three phase induction motor: comprehensive review
    B. Hafez Bahgat
    Enas A. Elhay
    Mahmoud M. Elkholy
    Discover Electronics, 1 (1):
  • [9] Rotor Fault Detection and Diagnosis of Three Phase Induction Motor drive system
    Sreeja, V
    Mini, V. P.
    Ushakumari, S.
    2015 INTERNATIONAL CONFERENCE ON CONTROL COMMUNICATION & COMPUTING INDIA (ICCC), 2015, : 212 - 217
  • [10] Electrical Fault Detection in Three-Phase Induction Motor Based on Acoustics
    Abdo, Ali
    Siam, Jamal
    Abdou, Ahmed
    Mustafa, Rashad
    Shehadeh, Hakam
    2020 20TH IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2020 4TH IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC/I&CPS EUROPE), 2020,