Minimally invasive percutaneous plating of proximal humeral shaft fractures with the Proximal Humerus Internal Locking System (PHILOS)

被引:60
|
作者
Brunner, Alexander [1 ]
Thormann, Sebastian [1 ]
Babst, Reto [1 ]
机构
[1] Cantonal Hosp Lucerne, Dept Trauma Surg, CH-6000 Luzern 16, Switzerland
关键词
MIPO; minimally invasive; percutaneous; humeral fractures; PHILOS; DYNAMIC COMPRESSION PLATE; ANGULAR-STABLE PLATE; DIAPHYSEAL FRACTURES; INTRAMEDULLARY NAIL; OSTEOSYNTHESIS MIPO; FIXATION; SHOULDER; EXPERIENCE; TRAUMA; MIDDLE;
D O I
10.1016/j.jse.2011.05.016
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: This study evaluated our results after minimally invasive percutaneous plating of proximal humeral shaft fractures with the Proximal Humerus Internal Locking System (PHILOS, Synthes, Switzerland). Materials and methods: Between 2005 and 2008, 15 patients with unilateral displaced proximal humeral shaft fractures were treated and followed up over a median period of 27 months (range, 12-38 months). The final follow-up included anteroposterior and lateral x-rays, range of shoulder motion, pain by visual analog scale (VAS), the Constant-Murley shoulder score, the Disabilities of Arm, Shoulder and Elbow (DASH) score, and the Short Form 36 (SF36) assessment. Results: No intraoperative or postoperative complications occurred. No secondary fracture displacement or radial neuropathy was observed postoperatively. One patient had open reduction and internal fixation for pseudoarthrosis 16 months after the initial surgery. At the final follow-up, the median range of motion of the operated shoulder was flexion, 145 degrees; extension, 45 degrees; internal rotation, 40 degrees; external rotation, 70 degrees; and abduction, 135 degrees. Median results on outcome assessments were VAS pain score, 0 points; Constant-Murley score, 74 points, representing 87.5% of the median Constant-Murley score of the unaffected shoulder; DASH score, 34 points, and the SF36, 83 points. Conclusion: Minimally invasive percutaneous plating with the PHILOS offers a valid option in the treatment of proximal humeral shaft fractures with comparable rates of nonunion and lower rates of radial neuropathy compared with open procedures. Furthermore, the results indicate that this method is associated with lower rates of wound infection and a shorter stay in the hospital for the patient. Level of evidence: Level IV, Case Series, Treatment Study. (C) 2012 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:1056 / 1063
页数:8
相关论文
共 50 条
  • [41] Minimally invasive plate osteosynthesis for proximal humeral fractures
    Koljonen, Paul Aarne
    Fang, Christian
    Lau, Tak Wing
    Leung, Frankie
    Cheung, Nigel W. K.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2015, 23 (02) : 160 - 163
  • [42] Minimally invasive poly-axial screw plating for three-part fractures of the proximal humerus
    Barco, R.
    Barrientos, I.
    Encinas, C.
    Antuna, S. A.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 : S7 - S11
  • [43] Does the magnitude of injuries affect the outcome of proximal humerus fractures treated by locked plating (PHILOS)?
    Berk, Till
    Halvachizadeh, Sascha
    Bellmann, Frederik
    Busser, Lucas
    Pape, Hans-Christoph
    Allemann, Florin
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2022, 48 (06) : 4515 - 4522
  • [44] Modified use of a proximal humeral internal locking system (PHILOS) plate in extra-articular distal-third diaphyseal humeral fractures
    Sohn, Hoon-Sang
    Shin, Sang-Jin
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (07): : 1300 - 1305
  • [45] Proximal humeral internal locking plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures A randomized study
    Chen, Xiong
    Yu, Zheng-Xi
    Wang, Huai-Yun
    Shen, Feng
    Lin, Guo-Bing
    Wang, Sheng
    Yin, Zong-Sheng
    MEDICINE, 2019, 98 (17)
  • [46] Comparison of the clinical outcomes and radiological parameters between the greater tuberosity strengthened proximal humeral plate and the proximal humeral internal locking system plate in the minimally invasive plate osteosynthesis treatment of proximal humeral fractures involving the greater tuberosity: a retrospective cohort study
    Le, Jiadi
    Lu, Jianpeng
    Zhang, Jianxiong
    Wu, Zhenghao
    Chen, Long
    BMC MUSCULOSKELETAL DISORDERS, 2025, 26 (01)
  • [47] Outcome of locking compression plating for proximal humeral fractures: a prospective study
    Chowdary, Umapathi
    Prasad, Hari
    Subramanyam, P. Krishna
    JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (01): : 4 - 8
  • [48] Newly designed minimally invasive plating of a humerus shaft fracture; a different introduction of the plate
    Lee, Tongjoo
    Yoon, Jaesik
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (12) : 2597 - 2602
  • [49] Comparison of classical and minimally invasive superolateral approach for reconstruction of proximal humerus fractures with locking plates
    Hustin, Louis
    Amouyel, Thomas
    Saab, Marc
    Chantelot, Christophe
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55
  • [50] Complications following intramedullary nailing of proximal humerus and humeral shaft fractures: a systematic review
    Lunn, Kiera
    Hurley, Eoghan T.
    Adu-Kwarteng, Kwabena
    Welch, Jessica M.
    Levin, Jay M.
    Anakwenze, Oke
    Boachie-Adjei, Yaw
    Klifto, Christopher S.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2025, 34 (02) : 626 - 638