Evaluation of anterior segment parameters with two anterior segment optical coherence tomography systems: Visante and Casia, in primary angle closure disease

被引:10
作者
Angmo, Dewang [1 ]
Singh, Reena [1 ]
Chaurasia, Shweta [1 ]
Yadav, Suresh [1 ]
Dada, Tanuj [1 ]
机构
[1] All India Inst Med Sci, Dept Ophthalmol, Dr Rajendra Prasad Ctr Ophthalm Sci, Glaucoma Res & Clin Facil, New Delhi, India
关键词
Angle parameters; anterior segment optical coherence tomography machines; Casia ASOCT; comparison; FD-OCT; primary angle closure disease; Visante ASOCTSS-OCT; SCLERAL SPUR; GLAUCOMA; EYES;
D O I
10.4103/ijo.IJO_641_18
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To determine the comparability of anterior chamber biometric measurements in primary angle closure disease (PACD) patients using two commercially available anterior segment optical coherence tomography machines (ASOCT): Visante and Casia. Methods: This was a cross-sectional observational study, which included clinically, diagnosed cases of PACD. Anterior segment biometric measurements were done using Casia and Visante ASOCT. Parameters studied were central corneal thickness (CCT), anterior chamber depth (ACD), nasal (N) and temporal (1) angle opening distance at 500 mu m (AOD500) and 750 mu m (AOD750), and N and T trabecular iris space area at 500 mu m (TISA500) and 750 mu m (TIM 750). Results. Total 36 PACD patients (72 eyes) with average age of 59.48 +/- 7.95 years were recruited, out of which 25 were females (69.44%) and 11 males (30.56%). The mean measurements of CCT, ACD, AOD500, and TISA on Casia and Visante machines were 522.5 +/- 34.75 mu m and 539.55 +/- 29.56 mu m (P = 0.00); ACD- 2.144 +/- 0.38 mu m and 2.133 +/- 0.39 mu m (P = 0.487); AOD500-0.27 +/- 0.16 mu m and 0.21 +/- 0.10 mu m (P = 0.04); and TISA500-0.100 +/- 0.07 mu m and 0.063 +/- 0.03 mu m (P = 0.00), respectively. A statistically significant difference was noted in CCT, N and T AOD, and TISA. A good corelation for ACD and CCT (ACD = 0.9816 and CCT = 0.772) only were noted between the two machines. The Bland-Altman plot analysis of different parameters between two machines has revealed good agreement of measurement of ACD and CCT but poor agreement for rest of the parameters. Conclusion: It is advisable not use the two machines interchangeably because of the wide limits of agreement and poor correlation of angle measurement values of Casia and Visante ASOCT.
引用
收藏
页码:500 / 504
页数:5
相关论文
共 50 条
  • [41] Identification of peripheral anterior synechia with anterior segment optical coherence tomography
    Dai, Yingying
    Zhang, Shaodan
    Shen, Meixiao
    Jin, Zi
    Zhou, Yuheng
    Ye, Shuling
    Bao, Chenhong
    Zhu, Dexi
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (09) : 2753 - 2759
  • [42] Anterior Chamber Angle Assessment by Anterior-segment Optical Coherence Tomography After Phacoemulsification With or Without Goniosynechialysis in Patients With Primary Angle Closure Glaucoma
    Shao, Tingting
    Hong, Jiaxu
    Xu, Jianjiang
    Le, Qihua
    Wang, Jiajian
    Qian, Shaohong
    JOURNAL OF GLAUCOMA, 2015, 24 (09) : 647 - 655
  • [43] Anterior segment optical coherence tomography in glaucoma
    Mueller, M.
    Geerling, G.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2008, 225 (03) : 194 - 199
  • [44] Progressive Changes in the Anterior Segment and Their Impact on the Anterior Chamber Angle in Primary Angle Closure Disease
    Kwak, Jiehoon
    Shon, Kilhwan
    Lee, Yunhan
    Sung, Kyung Rim
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 257 : 57 - 65
  • [45] Optical coherence tomography in anterior segment imaging
    Kalev-Landoy, Maya
    Day, Alexander C.
    Cordeiro, M. Francesca
    Migdal, Clive
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2007, 85 (04): : 427 - 430
  • [46] Comparison of measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy
    Yu, Zi-Yan
    Huang, Ting
    Lu, Lu
    Qu, Bo
    WORLD JOURNAL OF CLINICAL CASES, 2020, 8 (15) : 3249 - U143
  • [47] Anterior segment changes after pharmacologic mydriasis using Pentacam and optical coherence tomography in angle closure suspects
    Guo, Jing-Min
    Xu, Xiao-Lan
    Zhang, Hong
    Wang, Jun-Ming
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (05) : 980 - 984
  • [48] Modeling of gonioscopic anterior chamber angle grades based on anterior segment optical coherence tomography
    Yingying Dai
    Shaodan Zhang
    Meixiao Shen
    Yuheng Zhou
    Mengyi Wang
    Jie Ye
    Dexi Zhu
    Eye and Vision, 7
  • [49] Characteristics and reproducibility of anterior chamber angle assessment by anterior-segment optical coherence tomography
    Kim, Dong Y.
    Sung, Kyung R.
    Kang, Sung Y.
    Cho, Jung W.
    Lee, Kyoung S.
    Park, Seong B.
    Kim, Soon T.
    Kook, Michael S.
    ACTA OPHTHALMOLOGICA, 2011, 89 (05) : 435 - 441
  • [50] Understanding diagnostic disagreement in angle closure assessment between anterior segment optical coherence tomography and gonioscopy
    Porporato, Natalia
    Baskaran, Mani
    Tun, Tin A.
    Sultana, Rehena
    Tan, Marcus
    Quah, Joanne HuiMin
    Allen, John C.
    Perera, Shamira
    Friedman, David S.
    Cheng, Ching-yu
    Aung, Tin
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2020, 104 (06) : 795 - 799